Photovoltaic Reference Cells
See Also: Photovoltaic Cell, Solar Reference Cells
-
Product
Solar Simulator for Multijunction Solar Cells
-
For series connected multijunction cells, at a given spectrum (e.g. AM 1.5 or AM 0 for space solar cells), one of the cells will limit the current in the series connection of cells. All solar simulators deviate from the true AM 1.5 spectrum, and they are only classified in wide spectral bands (100nm width). So even for class A or A+ solar simulators, it can easily happen that the bandgaps of the multijunction cells are such distributed that the 'wrong' cell will limit the current, if a solar simulator with fixed spectrum is used. In the 70s and 80s, when these measurements were first developed, intercomparisons showed deviations of cell efficiency in fixed spectrum solar simulators of more than 40%.
-
Product
Reference Standard
-
Beijing GFUVE Electronics Co.,Ltd.
It has been designed for universal laboratory and test applications and is intended for checking and the calibration of reference standards for electrical power and energy.
-
Product
Load Cell Amplifier Signal Conditioner with Removeable Terminals
MODEL LCA-RTC
-
The LCA-RTC Module provide low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-RTC comes with removable screw-clamp terminal connectors, which accept wires without soldering.On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film potentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.
-
Product
PXI Mixed Configuration Relay Module - 6 Cells Populated
40-138-AA-BB-CC-DD (6 CELL)
Relay
The 40-138 2A Relay Module with 6 cells populated is a cell-based mixed configuration switching module suitable for applications requiring medium power switching with high density. It provides a broad selection of mixed relay types for greater flexibility and features 2A current capacity and voltages to 300VDC/250VAC.
-
Product
Low Capacity Single Point Bending Beam Load Cells
LSP SERIES
-
The LSP Series is a low capacity, low cost, high accurate single point bending beam load cell. It is ideal for OEM applications such as electronic scales and weighing machines. The single point design is highly resistant to eccentric loading allowing direct mounting to the scale base and weighing platform. The LSP Series features a moisture proof sealant.
-
Product
Spectro UV-Vis Double PC 8 Auto Cell Scanning Spectrophotometer
UVD-3200
-
Spectro UV-Vis Double PC 8 Auto Cell is a high performance UV-Vis double beam automatic scanning spectrophotometer. Spectro UV-Vis Double has a brand new optical system design, microcomputer controlled. It is capable of processing data, from analytical and spectrum testing. Precise with high accuracy of measurement and stability are also provided by the powerful built in software and large LCD screen, which can display the screen menu and other functions.
-
Product
COM Express® Type 6 Reference Carrier Board in ATX Form Factor
Express-BASE6
Computer on Module
The Express-BASE6 is an ATX size COM Express Type 6 reference carrier board. Together with the COM Express Type 6 module of your choice and off the shelf add-on cards, you can quickly emulate the functionality of your desired end product for software development and hardware verification.
-
Product
Spectroelectrochemical Flow Cell
SEC-2F
-
Using the spectroelectrochemical flow cell, it is possible to have a different optical path length changing the gasket. We offer, as an optional item, a silicon and Teflon gasket with a 100, 250 and 500 m of the thickness. SEC-2F Spectroelectrochemical flow cell was designed to fit perfectly in the SEC2000 Spectrometer, and it eliminated the use of the optical fiber to connect the Spectrometer to the SEC-2F. Even for another brand of the spectrometer, you can connect the SEC-2F using the collimating lens and optical fiber.
-
Product
Load Cell Measurement
-
Designed specifically as a single-board solution for material testing system (MTS) applications, the PCI-9524 combines a high 24-bit resolution with 1/200,000 count accuracy to provide the most precise load cell measurement PCI board available in the market today.
-
Product
Reference Supplies
-
Advanced Energy's Trek reference supplies offer both high temperature and time stability outputs. They can also be used as a secondary traceable standard.
-
Product
COM Express® Type 6 R3.1 Reference Carrier Board In ATX Form Factor
Express-BASE6 R3.1
Computer on Module
Express-BASE6 R3.1 is an ATX COM-Express Type 6 Basic / Compact size module reference carrier board based on PICMG COM-Express Revision 3.1. Together with the COM-Express Type 6 module of your choice and off the shelf add-on cards, you can quickly emulate the functionality of your desired end product for software development and hardware verification.
-
Product
Load Cell Amplifier Signal Conditioner with DB9 Connectors
MODEL LCA-9PC
-
The LCA-9PC Module provides low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-9PC comes with DB9 male and female connectors, which require soldering to user-furnished mating female or male wire connectors. On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film otentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.
-
Product
Three Phase Reference Standard Meter
-
Signals & Systems India Private Limited
The Three Phase Reference Standard Meter (TPRS-1107) is portable equipment from SANDS. The main objective of this device is to calibrate the errors in three-phase and single-phase energy meters i.e. the meter under test (MUT). The TPRS supports both static and electro-mechanical types of meters. It can also be used to compute the voltage, current, energy, power factor etc of the meter under test. It has an LCD display, an alphanumeric keypad that makes it easy for the user to operate the TPRS. It can be interfaced with the PC for data analysis. It has the capability of storing up to 8000 test results.
-
Product
Economical Bending Beam Load Cells
EBB SERIES
-
The EBB Series is a economical low capacity bending beam load cell suitable for use in a variety of industrial and OEM force measurement and weighing applications. It is made of an aluminum alloy and comes in 1, 2, 5 and 10 kilogram ranges.
-
Product
Radial Flow Cell
-
The wall jet of the sample, after hit in to the surface of the electrode, spreads in three dimensions. After hitting the sample on a thin layer electrode directly, it flows to the perimeter from the center of the radiated electrode, improving the sensitivity.
-
Product
Pancake Load Cell
-
Futek Advanced Sensor Technology, Inc.
The Pancake Load Cell category offers 20 models built for Endurance, Off-Center Loading, or Inline applications. These models are available in a wide capacity
-
Product
load cell
EST-40
-
Technopark Automation & Control
The EST-40 is an 'S' type load cell suitable for use in tension and compression and is popular on hopper, tank weighing, belts scale and process weighing applications. It is low cost and is available in capacities from 50 kg to 2000 kg.
-
Product
High Precision Compression Type Load Cell
ZR
-
A high-precision compression-type load cell is a sensor that accurately measures compressive (pushing) forces, designed for applications requiring very tight accuracy and reliability. It works by converting a downward force into an electrical signal, often using strain gauges to measure deformation, and is used in demanding fields like calibration, manufacturing, and medical equipment.
-
Product
DynoLAB Test Cell Supervisory System
-
SAKOR Technologies’ DynoLAB™ data acquisition and control systems offer reliable, cost effective automation of all types of dynamometer test systems. As with all SAKOR products, the DynoLAB system undergoes a continuous program of upgrade and improvement, regularly expanding and enhancing DynoLAB’s capabilities.
-
Product
TurboFan Test Cells
-
Atec, Inc. is an industry-preferred provider of full scale TurboFan test cell design, construction, maintenance, and refurbishment. Our seasoned aeroengine professionals and comprehensive network of international locations and resources provide our customers with unparalleled expertise and value for their most critical and complex test cell projects.
-
Product
Load Cell Indicators
-
Procter & Chester Measurements Ltd
The instrumentation will power the load cell. The mV/V signal coming back from the load cell is converted by the indicator and displays the force in a unit (e.g.: Kg, kN, lb – customers choice). The indicators within this range are encased so that the operator can either use it on the move (if battery powered) or be a permanent fixture, e.g.: wall mounted.
-
Product
Single Cell Hardware
-
A Fuel Cell Hardware Assembly consists of a pair of Poco Graphite Blocks with a precision, machined flow-pattern (pattern is serpentine unless otherwise specified by the customer), and a pair of gold plated connectors fastened with aluminum end plates. Gas inputs and outputs are through Swagelok fittings. A thermocouple well and two cartridge heaters are also provided. A single Anode Reference Electrode may be added for an additional cost. The FCT Cell Hardware does not include a Membrane Electrode Assembly (MEA).
-
Product
Frequency Reference
E8-X
-
The Quartzlock E8-X is a breakthrough in exceptionally low cost, miniature, traceable, calibration-free, off-air frequency & time standards. These references maintain the high frequency & time accuracy required for demanding applications.
-
Product
Signature Compression Only Load Button Load Cells
SLB SERIES
-
The SLB Series Subminiature load cells (Load Buttons) are offered for compression only applications where space is limited. The matching surface must be flat for ultimate accuracy. The loading diameter is slightly convex for accurate load distribution. These sensors are manufactured from heat treated 17-4ph stainless steel, and the sensing element incorporates bonded foil strain gages of the highest quality. They are sealed for protection against most industrial environments.
-
Product
Battery Cell Surge Tester
Chroma 19311
-
Chroma Systems Solutions, Inc.
The 19311-10 has 10 channels, which can test up to 9 battery cells via scanning test, with a single unit. It can support up to 25 channels for testing up to 24 cells in a sequence by connecting with an external scanner (A190362). The test speed of the multicell scanning test by 19311-10 is extremely efficient, saving test time, and decreasing labor costs. It also increases the production capacity of the production line.
-
Product
PXI Mixed Configuration Relay Module - 10 Cells Populated
40-138-AA-BB-CC-DD (10 CELL)
Relay
The 40-138 2A Relay Module with 10 cells populated is a cell-based mixed configuration switching module suitable for applications requiring medium power switching with high density. It provides a broad selection of mixed relay types for greater flexibility and features 2A current capacity and voltages to 300VDC/250VAC.
-
Product
Solar Photovoltaics
-
The conversion of light into electricity using semiconducting materials that exhibit the photovoltaic effect, a phenomenon studied in physics, photochemistry, and electrochemistry.
-
Product
PXI Mixed Configuration Relay Module - 8 Cells Populated
40-138-AA-BB-CC-DD (8 CELL)
Relay
The 40-138 2A Relay Module with 8 cells populated is a cell-based mixed configuration switching module suitable for applications requiring medium power switching with high density. It provides a broad selection of mixed relay types for greater flexibility and features 2A current capacity and voltages to 300VDC/250VAC.





























