Power Factor
measures true power over apparent power.
-
Product
Artificial Phantom Load with Power Factor
RC-50
-
The RC-50 Artificial Phantom Load has been re-designed to meet the most exacting requirements. It operates from a single phase source and will deliver current at either unity or 50% power factor at all full load ranges. Features: Artificial Load, Light Weight, 50 Amps, 50% Power Factor.
-
Product
Power Factor Controllers
-
ENTES Reactive Power Factor Controllers try to match the system''s power factor which is defined as the ratio of the active power to the apparent power to the user defined power factor value by controlling the facility''s reactive power using capacitor banks.
-
Product
Intelligent Power Factor Regulator
Model -KM PFR 9-6 / 9-12
-
Kusam Electrical Industries Limited
The pioneers & leaders in high quality power factor controllers & maximum demand controllers, now introduce 2 new economy models of power factor controllers. These controllers have microprocessors for automatic control of power factor. It has digital indication for power factor.
-
Product
True RMS 1000V Wireless Multimeter w/ Power Factor
DM525
-
UEi Test & Measurement Instruments
The DM525 is a Industrial level multimeter with Wireless capability and a free App. It also has Watt/Power Factor lessening the chance of incorrect readings from ghost voltages. The increased functionality gives technicians the ability to do more.
-
Product
Portable Power Factor Meter
ST-2000 Cos∮
-
Standard Electric Works Co., Ltd
● Principle : Phase angle sensing transducer● Rated Accuracy : ±3% phase angle● Scale : Power Factor:Lead 0 – 0.3 – 1.0 – 0.3 – 0 Lag Power Angle: Lead 90° – 0° – 90° Lag● Effective Power Factor Measuring Range : Lead 0.5 – 1.0 – 0.5 Lag● Scale Length : Approx. 135mm(5-3/8”)● Frequency Influence : Within ±1.5° phase angle at 45 to 65Hz
-
Product
Phase Angle and Power Factor Transducer of Single-phase AC Electric Power
NMTFi
-
The NMTFi device is a phase angle and power factor transducer operated in single-phase power network and featuring two independent analogous outputs. The A output measures the phase angle between voltage and current, the B output measures the power factor. In such a was one single NMFTi transducer is able to replace two customary transducers thus making it possible to achieve significant savings in installation space.
-
Product
Amp, Power Factor & VAR Recorder
Varcorder
-
The Varcorder measures and records Amps and Power Factor. A voltage constant is then applied in software to calculate VARs. The Varcorder uses the same current sensor technology as the original Ampstik. This patented amp sensor does not use magnetic materials and has no moving parts. The opening of the sensor is electronically closed, and external currents are electronically rejected. The accuracy, external current reject, and range of currents measured by the patented amp sensor substantially exceed the performance of the best clamp-on sensors. The true power factor is calculated by measuring the electric field in comparison with the current reported from the amp sensor. The key feature of the unit is the ability to leave it deployed on the line to record readings every 15 minutes for 90+ days. It easily attaches to the line with a standard shotgun style hotstick. Once on the line, it immediately begins to collect and record the current and power factor on the line.
-
Product
Portable Wattneter (Low Power Factor 0.2)
-
Supreme Instrument Laboratories
Range : 0-0.5/1 Amps, 0-50/100/200 Volts.0-0.5/1 Amps, 0-75/150/300 Volts0-0.5/1 Amps, 0-150/300/600 Volts0-0.5/1 Amps, 0-125/250/500 Volts
-
Product
Automatic Power Factor Controller
-
Nippen Electrical Instruments Co.
NIPPEN Model UNO+ is used for measurement and control of PF using Reactive power compensation. Capacitor banks are suitably switched ON and OFF automatically to provide necessary compensation.An Intelligent switching algorithm (Wear leveling) ensures uniform aging of the capacitors used to achieve the Target PF. An Alarm function ensures protection of capacitor banks against abnormality in voltage, current and sets value of capacitors whenever these are beyond the higher and lower threshold limits.CT polarity is automatically sensed internally in the event of reverse connection.
-
Product
GDGS Transformer Power Factor And Tan Delta Tester
-
Chongqing Gold Mechanical & Electrical Equipment Co.,Ltd
GDGS Transformer Power Factor and Tan Delta Tester
-
Product
Capacitance & Tan Δ Power Factor Meter 12kV
CAPO-12
-
The CAPO 12 is a fully automatic Capacitance, Insulation Power Factor / tan δ measuring instrument developed by Raytech Engineers. The self-contained instrument performs measurements of Insulation Power Factor (cos ᵠ), Dissipation Factor (tan δ), Capacitance, Inductance, Excitation, Quality Factor and Power Loss (watts). Measurements can be made up to 12kVAC at variable frequency (from 10Hz to 400Hz).
-
Product
Power Factor Controller
R5&R8
-
DUCATI energia introduces the new and innovative R5 and R8 power factor controllers. The compactness, the latest technology and the complete range of features make the R5 and R8 models extremely adaptable to any application context in the field of power factor correction systems for both single-phase and three-phase networks of low and medium voltage with a lot of connectivity options.
-
Product
Digital Panel Meter
-
Shenzhen Star Instrument Co., Ltd.
Three-phase energy meter measures energy, voltage harmonics, current harmonics, voltage, current, power and power factor.
-
Product
AC-DC Converters
-
With robust, advanced high-voltage converters, power factor correctors, a variety of controllers and supervisors/housekeeping ICs, together with innovative architectures and extended temperature ranges.
-
Product
Customaizable Uninterrupted Power System
CT Series
-
The rugged CT Series is designed for applications in extreme temperature environments, such as offshore drilling rigs, refineries and shipboard use. An added benefit is that the CT Series can double as an electronic power conditioner/frequency converter as well. All CT systems utilize Power Factor Correction, and RS232 and SNMP protocols are supported.
-
Product
High Performance Programmable AC Power Source
61500 Series
-
Chroma 61500 Series have built in 16-bit measurement circuits and firmware utilities to measure the true RMS voltage, current, true power, apparent power, reactive power, power factor, current crest factor, and inrush current.
-
Product
Closed-Link Field Test Kit
630
-
TESCO’s Closed-Link Field Test Kit (Catalog No. 630) with Power Factor has been designed to reduce the weight of field test equipment to the lowest possible limit when testing electric meters without potential links or with the links closed. The unit is protected within its ergonomic carrying case by a durable powder coated aluminum shell. The total weight of the meter test kit including leads, and digital reference standard is only 30 lbs! The test kit carrying case also incorporates ample storage space for the cable set and other tools.
-
Product
Multifunction Power Transducer With Display
Model TRMT MULTIFUNCTION POWER
-
Kusam Electrical Industries Limited
• Easy Installation & Space saving.• Simultaneous detect & display : - Individual Phase to neutral Voltage - Individual Phase Current - Individual Phase watt. - Frequency - Phase to Phase Voltages. - - Power Factor - - Total Watt - - Total Var
-
Product
Reactor Loss Measurement Systems
-
Measurements International Ltd.
The AccuLoss® SR2020 System by Measurements International emerges as a premium, dependable solution tailored for measuring losses in high-voltage shunt reactors. Specifically engineered to function seamlessly at remarkably low power factors, this system excels in applications demanding extensive scalability. Notably, the AccuLoss® SR2020 System offers two key advantages: unparalleled accuracy and remarkable speed.
-
Product
Single Phase Portable Energy Meter Test Bench Type KP-P1003-C
-
Bofa Instrument & Equipment Co., Ltd
Single-phase portable test bench, Type KP-P1003-C, is an ideal device to test all kind single-phase energy meters accuracy below 1.0. The equipment can generate single-phase voltage, current and all power factor. The equipment is box structure, light, and easy to carry, it is a very ideal device for energy meter factory to adjust meter at production line, it also can be used as testing equipment in R&D institute.
-
Product
Light Compensation Capacitor
CBB80
-
Designed for lighting applications such as fluorescent lamps,high-pressure mercury vapor lamps,sodium lamps,and metal halide lamps. The capacitors are used for power factor compensation of transformers and magnetic ballasts in lamps with a frequency of 50Hz or 60Hz,which makes the power factor to achieve cosφ 0.9. The temperature
-
Product
Clamp Meter, Auto, True RMS, 1 kA AC, 600 V AC, 50 mm Jaw Opening Max.
72-10445
-
The 72-10445 is a Clamp Power Meter Clamp with phase sequence. It measures active power (W), apparent power (VA), reactive power (VAr), power factor, phase angle and active energy (Wh) with built-in phase sequence test. Also measures AC current, AC voltage and frequency.
-
Product
Programmable AC Power Source
Model 8600 Series
-
- Compact size and light weight, standard 19″ rack construction- Step-less frequency setting from 45 to 450Hz- Very low distortion sine wave output- Output voltage range selectable 135 or 270V AC- Galvanically isolated input/output- Independent on/off switch for input and output- 16×2 vacuum florescent display for parameter display- Complete operation through push switches and a digital rotary encoder- Automatic protection against overload, short circuit and over temp.- Built in PFC to provide 0.99 input power factor and wide input range- Conforms to EN55022, class A, safety standard EN60950
-
Product
X-Ray Inspection System
TruView™ Cube
-
The Perfect Solution for a Powerful Small Form Factor X-ray Inspection System. The all new TruView™ Cube X-Ray Inspection System is a fully motorized radiography system developed to meet the stringent requirements of electronics assembly and component inspection. Ideal for applications where space is premium, the the TruView™ Cube X-Ray sits comfortably on your laboratory bench.
-
Product
Injection Transformer
J2101A
-
The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.
-
Product
AC Line Harmonics Analyzer
HA1600A
-
Compliance quality measurements to EN61000-3-2 and EN61000-3-3Measures peak or rms voltage or current, real or apparent power, power factor, phase etc.Tabular/histogram of 40 harmonicsVoltage/current waveforms displaysContinuous analysis with real-time graphical updateWide range of power connectors available320 x 240 pixel high-contrast displayUSB, RS232 and printer interfaces fittedPC control and documentation software supplied (HA-PC-Link+)
-
Product
Resistive & Capacitive, Inductive AC Load Bank
RLC
-
Inductive & capacitive load banks are reactive only and must be used in combination with a resistive load bank to provide the desired load profile to test a power system. Reactive loads banks can provide either a leading power factor (Capacitive) or lagging power factor (Inductive).
-
Product
MCB Instantaneous Trip Test Bench
-
The SCR Elektroniks MCB Instantaneous Trip Test Bench is designed for Testing of MCB to carry out “Test of Instantaneous Tripping and of correct opening of the Contacts” as per IEC: 60898-1:2002 Clause 9.10.2 at rated voltage. This test is carried out with power factor between 0.95 and 1 with the sequence operation being O-t-CO-t-CO-t-CO with timings as specified in 9.12.11.1.
-
Product
Capacitors And Reactors, LV
-
Wide range of cylindrical and prismatic capacitors for power factor correction in 50 or 60 Hz networks. Models with Heavy Duty system to ensure enhanced performance in extreme environments. Reactors are required to protect capacitors in installations with a high presence of harmonics, maintaining their characteristics and useful life without affecting their operation.





























