-
Product
GTEM cells
-
Meets IEC/EN 61000-4-20, SAE J1752/3, IEC 62132-2 and IEC 61967-2. The GTEM cell is, in principle, a tapered coaxial line (offset septum plate), which is terminated by a hybrid combination of discrete resistors and RF absorbers to achieve a 50 Ohm broadband match. It is applied for Measuring of Emission, Radiated, radio frequency field-immunity test.
-
Product
Test Cells
-
LaplaCells provide a facility for the rapid and efficient testing of the EMC compliance of products. These cells offer a calibrated and screened environment in which radiated emissions can be measured and immunity to RF radiation can be tested. They exceed the requirements of IEC61000-4-20, thus affording compliant testing to IEC61000-4-3 and pre-compliance testing for radiated emission testing. The Cells are a modified form of GTEM cell, using a balanced dual septum design which maximises EUT volume for a given external size of cell, and dramatically improves field linearity. The EUT volume is fully lined in structural polycarbonate capable of supporting heavy products and access is via a large, full height door at the end of the cell. Adjacent to the door is the I/O filter compartment which can be customised to suit the users requirements. USB, RS232, Parallel, Ethernet, co-ax and other product specific filters can be added at time of ordering.
-
Product
TDK Software
-
TDK Software - Testlab, Emissions Lab, Cundicted Immunity Lab, Radiated Immunity Lab, EUT Monitoring Lab, GTEM Emissions Lab
-
Product
Resistivity Cell For N1413 (50 Mm Electrodes)
N1424A
Resistivity Cell
The N1424A is designed to operate specifically with the B2985B/87B Electrometer/High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1424A to the B2985B/87B.
-
Product
Resistivity Cell For N1413 With B2980 Series (26/50/76 Mm Diameter Electrodes)
N1424C
Resistivity Cell
The N1424C is designed to operate specifically with the B2985B/87BElectrometer/High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1424C to the B2985B/87B.
-
Product
CELL TESTER
SPOTLIGHT
-
SpotLIGHT was designed to minimize maintenance and to significantly reduce downtime. The lifecycle of its contacting system is longer than that of standard systems currently available on the market, thus substantially reducing TCO.
-
Product
Load Cells
-
Force Logic UK provides high-quality load cells, load indicators, and force measurement systems for a variety of industries. All our load cells are manufactured in the UK, and have passed through rigorous quality control standards for precise and accurate measurement, load monitoring systems, and industrial weighing applications. They are suitable for the measurement of static loads and dynamic forces in tension or compression, our load cells cover a wide range of mechanical forces, from 1kg to 1000 tonnes.
-
Product
Load Cells
-
is a transducer that is used to create an electrical signal whose magnitude is directly proportional to the force being measured.
-
Product
Cell Production
-
JRT Photovoltaics GmbH & Co. KG
The production of lithium-ion cell batteries includes the three main process stages of electrode production, cell assembly and formation and aging. Automation is a critical factor for success, particularly in the process stage of cell assembly.
-
Product
HOT CELLS
-
Precisely engineered and constructed for continuous dependable protection and reliable everyday laboratory use. These cells come standard with shielding for the ionization chamber and utility connections.
-
Product
Liquid Battery Test Cell (Coin Cell Simulator)
LBT1
-
A liquid battery test cell designed for electrochemical research, battery experiments, and laboratory material evaluation, providing reliable sealing and repeatable testing performance.
-
Product
Load Cell Transmitter
MODEL SST-HV
-
The SST-HV is a Plug & Play Smart TEDS IEEE 1451.4 compliant Transmitter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the SST-HV will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the SST-LV Transmitter is easily programmed using a PC with an RS232 port and Instrument Setup (IS) software, which provides a graphical user interface. The SST-HV may be powered from 95-240 Vac ±10%. The SST-HV has an Isolated transducer excitation output that is selectable between 5Vdc or 10Vdc. There are Dual solid state relays and an Isolated 4-20 mA, 0-20 mA or 0-10V analog output. There are three Isolated serial data transmitter output ( RS232 , Half-duplex RS485, full-duplex RS485 ) and three serial protocols that are software selectable (Modbus RTU, Modbus ASCII and Custom ASCII). Isolation to 250V rms is provided for power, signal input, analog output, relay outputs, and communications. Isolation adds safety and avoids possible ground loops. The transducer excitation output is isolated to 50V from signal ground.
-
Product
Load Cell Transducer
-
Unitech Scales And Measurements Pvt. Ltd
Force can be measured by different methods, one of the most effective and accurate method is by using strain gauge based load cells. Four Transducer class strain gauges are bonded on the specimen and are connected in the form of Whetstone Bridge. The specimens are of different types depending on the requirement such as S, column, beam, ring, shear beam, binocular etc. UNITEH’S Load Cells are used for wide applications rite from commercial weighing scale to industrial process controlling, R & D applications and educational institutions. UNITECH’S manufacture load cells from 1Kg to 100Tons for compression or tension or universal (Compression and tension) applications. We also undertake custom built load cells for specific requirement and for OEM users.
-
Product
Permeability Cells
Flexible Wall Permeameter
-
The Permeability Cells - Flexible Wall Permeameter for Soil Samples performs permeability tests on normal and contaminated soil samples. The permeability cells are available either in brass for normal use or in stainless steel for contaminated materials. Top caps and pedestals are available for normal or contaminated materials.
-
Product
Cell Solar Simulator
QuickSun® 130E
-
QuickSun 130E exceeds the ordinary Class A criterions of IEC904-9 ed. 2 with clear margin providing enhanced IV characteristics accuracy. The applicable test methods and procedures are inspected by SGS Fimko Ltd in order to guarantee the compliance and traceability not only with the above standard but also with IEC904-1 ed. 2 which specifies the IV measurement conditions.
-
Product
Load Cells and Sensors
-
Our high quality load cells and sensors are used for materials testing and force measurement all over the world.
-
Product
Acrylic Electrolytic Cell
CAE-1
-
Custom acrylic electrolytic cell for electrochemical testing, electrolysis, and electrodeposition. Transparent PMMA body with customizable ports and dimensions.
-
Product
Small Cells
-
5G small cells enable additional capacity and coverage to networks when and where needed – both indoors and outdoors. Our 5G protocol software for small cells supports both sub-6 GHz and mmWave bands and leverages the Small Cell Forum’s FAPI and nFAPI open interfaces to work seamlessly on our partners’ SoC-based small cell platforms.
-
Product
Wireless Load Cells and Electronics
-
A wireless industrial weighing scale system can be advantageous, for instance when running conduit for cable is impossible, or if the cable could be damaged easily. In some cases the wireless interface is more economical than long runs of cable. These systems can be battery operated or hard wired to a power source if available. View our wireless load cell options below.
-
Product
Subsea Shackle Load Cell
SUBS-3.0
-
The Subsea Shackle Load Cell has been designed to measure loads in a subsea environment. DLM’s subsea shackles are suited to fit leading industry Crosby and GN shackles.
-
Product
Aviation Engine Test Cells
-
1.Design, manufacture and installation: ● Thrust stand components: thrust measurement system, adapter, superstructure etc. ● Facility subsystems: DAQ, supply systems (fuel, oil) etc.2.Civil construction works: site survey, building works etc.3.Contracting: ● Turn-key – MERA is able to supply a “turn-key” test cell including civil works, thrust stand, DAQ, all necessary facility subsystems, specialized software, throttle control level and etc. ● Joint – MERA is capable to supply specified items such as thrust stand with DAQ and software. The Customer is able to procure necessary items such as test nacelle directly from OEM. 4.Project management in accordance to EPC (Engineering, Procurement, Construction, FIDIC) 5.Certification in accordance to international and local standards and rules (SAE 5305) Engine types: PD-14, PS-90, RD-93, RD-33MK, AL-31FN
-
Product
PTFE Spectroelectrochemical Cell For Photocatalysis
PTS-1
-
PTFE spectroelectrochemical cell with quartz window for photocatalysis, supporting 3-electrode setups and horizontal light source. Available in 5–100ml with 24mm or 32mm window.
-
Product
Stimulus Test Cell
HA7300
-
The Stimulus Test Cell HA7300 is a test cell which provides an environment for high-speed, highly accurate temperature and pressure test of differential pressure sensors, utilizing Advantest’s unique temperature control unit with simultaneous temperature control for 8 devices, as well as a newly developed 2Port pressure controller and pressure application nozzle.
-
Product
Load Cells
-
Load cells are electronic weight sensors whose purpose is to receive the electrical excitation caused by a certain weight applied to the scale or balance and transmit it to a weight indicator . The load cell is an essential component in any scale or electronic balance and they come in different models and specifications. A Wim load cell is essential for a weighing system where precision, durability and a fair price are required. WIM-Systems manufactures a wide variety of load cell models, one for each need, in addition to offering all the advice you need to choose the model that best meets the particular needs of your weighing system and always backed by WIM-Systems quality and technology.
-
Product
Resistivity Cell For N1413 (26/50 Mm Electrodes)
N1424B
Resistivity Cell
The N1424B is designed to operate specifically with the B2985B/87B Electrometer/High Resistance Meter. It is used to measure surface or volume resistance/resistivity of insulation materials. The N1413A High Resistance Meter Fixture Adapter is required to connect the N1424B to the B2985B/87B.
-
Product
Dry Heat Diffusion Cells
Phoenix Series
-
The Phoenix™ Diffusion Cell provides improved ease of use, high durability, and greater versatility as compared to conventional hand-blown vertical diffusion cells. Phoenix cells operate on dry heat; no water-jacketing is required, allowing construction from heavy-duty borosilicate glass held to very tight dimensional tolerances. The extract-and-replace sampling through the large diameter opening in the sampling arm accommodates standard pipette tips (~300 μL), simplifying the sampling process while reducing training and operating costs.
-
Product
Rod End Load Cells
-
Our rod-end load cells are designed for integration into tension measurement. They are versatile, durable, and fit easily into small spaces such as inline with vehicle tie rods.





























