Emission
particles emanating from a source.
See Also: Acoustic Emission, Gas Emission, Radiated Emissions, Conducted Emission, Emission Reference Sources
-
Product
Acoustic Emission Transducer
GT205
-
Acoustic emission transducer is a key element of non-destructive acoustic emission testing. Transducers GT 301 are used for technical diagnostics by means of passive ultrasound.
-
Product
Standard Emission Monitoring System
CEMS-2000
-
CEMS-2000 is a multi-gas monitoring system aimed to continuously and reliably measure emissions from various industrial combustions. The adoption of the hot-wet extractive method avoids the loss of content during sampling. The system is extendable with additional parameters upon request. All output signals proceed through the data acquisition system and then upload to the DCS or environmental authority server.
-
Product
Principle Of Optical Emission Spectrometry
-
Optical emission spectrometry involves applying electrical energy in the form of spark generated between an electrode and a metal sample, whereby the vaporized atoms are brought to a high energy state within a so-called "discharge plasma".
-
Product
RSE Wireless EMC Spurious Emission
TS8996
Test System
The R&S®TS8996 RSE test system is designed for EMI and radiated spurious emission testing on wireless devices in semi-anechoic or fully anechoic chambers. The modular design makes it easy to extend the system to include new communications technologies. Typical devices under test include mobile phones or radio sets along with radiated measurements of other short-range devices. Standards require a wide range of test setups and a wide and high frequency range (up to 40 GHz). ESW or FSW frequency ranges are extended up to 325 GHz with option B21 using receive units TC-RSE for 5G FR2. Dedicated RSE test routines are also covered for this frequency range.
-
Product
Acoustic Emission (AE) Monitoring System
Sensor Highway II System
-
The Sensor Highway II System™ is an Acoustic Emission (AE) monitoring system with up to 16 high-speed channels and 16 standard parametric input channels (expandable to over 100). The system is designed for unattended and remote monitoring use in Structural Health Monitoring management and condition monitoring applications. It is rated for outdoor use and comes equipped in a rugged weather proof NEMA 4 enclosure.
-
Product
Handheld Emission Particle Counter
HEPAC
-
Naneos Particle Solutions gmbh
Exhaust gas contains a lot of humidity, which can condense in the measuring device when the gas cools down. This could lead to problems with the measurement. Therefore, corresponding sensors are heated or the gas gets previously diluted. Exhaust gases from petrol and natural gas vehicles, however, contain a lot more humidity, which is why the device should only be used for diesel exhaust gases.
-
Product
CEMS II E Continuous Emission Monitoring System
-
CEMS II e takes away the manual configuration and settings adjustments from your day-to-day emissions measurements. A fully automated continuous emission monitoring system CEMS II e is TÜV and MCERTS certified solution (QAL1) to offer environmental compliance. This emission monitoring system is suitable for measuring pollutants continuously from hot, wet and corrosive gas streams in various industrial processes, such as powerplants, waste incineration, cement plants and beyond.
-
Product
Emission software
EMiScan
-
This Windows Emission package is an ideal debug / development tool providing easy of use with a flexible approach so you can quickly capture and manipulate data
-
Product
Continuous Emission Monitoring Data Acquisition System
CEM-DAS
-
CEM-DAS is a complete networkable system for continuous recording and evaluation of emission data in all industries. The system provides important information for the environmental and economic operation of production facilities. CEM-DAS is scalable to support smallest one stack installations up to multi-block plants with numerous measuring points. CEM-DAS has proven its robustness in a German TÜV test which requires 99 % uptime.
-
Product
Continuous Emission Monitoring Systems
CEMS
-
IMR Environmental Equipment, Inc.
Continuous Emission Monitoring Systems (CEMS) is a class of hardware designed for extended process analysis.
-
Product
Sound Level Meter for Automotive – Car Noise Emission Inspection
HD2010MCTC
-
The level of noise produced by vehicles shall comply with standards prescribed by international regulations. During car inspections, horns and exhaust devices must be in good condition and comply with the requirements.
-
Product
Continuous Emission Monitoring Systems
-
TML has more than 50 years' experience designing, manufacturing, and supporting continuous emission monitoring systems (CEMS). We have a team of experienced CEMS air quality experts that will thoroughly review your process and operating permit and recommend the most cost effective and reliable solution for monitoring the gases of interest. TML's continuous emission monitoring systems are based on rugged, reliable equipment manufactured to exact standards. The result is products and systems with some of the highest mean time between failure rates in the industry. Whether it's a standard or custom solution, we stand behind our products 110%, guarantee CEMS certification, at least 95% uptime, replacement parts, and 24 x 7 support. We offer a total CEMS solution including data acquisition software for recordkeeping and reporting, lower cost of ownership, superior product reliability and designed for simple and easy maintenance.
-
Product
CDNE For Emission Measurement On Luminaries
-
CDNs have been used as coupling-/decoupling networks to measureconducted noise as well as for immunity testing so far.
-
Product
Inductively Coupled Plasma Optical Emission Spectrometer
EXPEC-6000
-
An analytical technique used to determine how much of certain elements are in a sample.
-
Product
Conducted Emission
-
AFJ FFT 3010 & 3030 EMI Receivers have been especially designed for conducted emission measurement, both during EUT diagnostic development and for final compliance testing.
-
Product
Engine Emission Test System
-
By adding transient operation functions (self-learning/predictive driving + each test mode performing) to measurement•control panel, Ono Sokki can build up engine test system that can perform transient mode tests supporting worldwide gas emission controls including TRIAS, FTP, EURO, and ISO. (e.g. WHDC, NRTC).This system provides good reproducibility for Transient mode test. Delay compensation and rotation inertia compensation function have greatly improved as well as self-learning / predictive driving function.Automatically processes from measurement to data output of test result, in conjunction with gas emission analyzer, tunnels, gas emission particle measurement system, smoke meter, etc.
-
Product
Sample Pretreatment For Optical Emission Spectrometry
-
Samples are taken from molten metal, thin sheet, semi-complete or complete products. When sampling molten metal with a ladle, small quantities of molten metal are poured into a casting mold. Unnecessary parts of the sample are removed using a grinder or a cutter. As particles from a grinder may contaminate the surface of the sample, a lathe or milling machine is used (not a grinder) to cut soft samples such as white metal. If trace elements are not being investigated, a grinder or belt sander can be used. However, to minimize contamination, the grinding wheel or belt should be changed for each sample. Samples excised from semi-complete or complete products must be at least 12 mm in diameter. Small rod-shaped samples can be analyzed using special equipment.
-
Product
Conductive Emission Measurement
-
Holland Shielding Systems B.V.
On site testing for exposure limits in working conditions to any international standard. This involve pacemakers and HSE Heath and safety executive, invitarisations worldwide.
-
Product
Emission Measurement Equipment
EPS Series
-
Nowadays, components mountings are getting dense accompanied with miniaturization of electronics equipments.Emission Measurement System "EPS series" are efficient tools to measure such radiation noise on PCB in normal office environments and visualize the noise strength on a PC display.
-
Product
Small Device Noise Emission Test System
-
The Small Device Noise Emission Test System from VIacoustics is a turnkey solution for the measurement of noise emissions of small devices typically used in computers, consumer electronics, appliances and automobiles. The system includes all hardware and software necessary (see the components tab) for the determinations of sound power levels (1/3 octave band and A-weighted), emission sound pressure levels (normalized 1/3 OB, A-weighted and high resolution FFT) and *ISO 532B loudness. The system is designed to be operated by a technician for production level testing or to be used by an engineer in the product development process.
-
Product
Inductively Coupled Plasma Optical Emission Spectroscopy / ICP-OES Systems
-
Industry-leading performance, speed and ease of use – no compromises
-
Product
Acoustic Emission Calibrator
-
AE calibrator is similar to a simple signal generator, it can generate a variety of controlled waveform signal, different types, different amplitude and different frequency. It can help users calibrate acoustic emission detection equipment before acoustic emission detection.
-
Product
Plasma Emission Detectors for Gas Chromatographs
-
Our patented Plasma Emission Detector is available for integration into any gas chromatography system or installation. It has been designed for ‘plug and play’ installation and to allow for analysis of impurities from PPB to % levels using either capillary or packed columns.
-
Product
Emission Analyzers
-
The VLT-E8104 emission analyser measures the opacity of the exhaust gases of vehicles with petrol/LPG/CNG engines. The accuracy complies with OIML class 0. An oil temperature sensor and an rpm counter can be connected.If you connect diesel smoke cell VLT-E9210, this analyser is a fully functionsl diesel smoke analyser as well.
-
Product
Proton Induced X-ray Emission (PIXE)
-
Elemental Analysis Incorporated, utilizing Proton Induced X-ray Emission (PIXE), provides a non-destructive, simultaneous analysis for the 72 inorganic elements from Sodium through Uranium on the Periodic Table for solid, liquid, and thin film (i.e. aerosol filter) samples. The PIXE technique offers the advantage of analysis, without the necessity for time consuming digestion, thereby minimizing the potential for error resulting from sample preparation.
-
Product
Optical Emission Spectrometers
-
Optical emission spectrometers (OES) and the measuring principle of the atomic emission are the ideal method and provide the perfect instrumentation for metal analysis in all different industrial businesses and environments.
-
Product
Acoustic Emission Instruments
-
The Acoustic Emission NDT technique is based on the detection and conversion of high frequency elastic waves into electrical signals.





























