Emission
particles emanating from a source.
See Also: Acoustic Emission, Gas Emission, Radiated Emissions, Conducted Emission, Emission Reference Sources
-
product
Sample Pretreatment For Optical Emission Spectrometry
Samples are taken from molten metal, thin sheet, semi-complete or complete products. When sampling molten metal with a ladle, small quantities of molten metal are poured into a casting mold. Unnecessary parts of the sample are removed using a grinder or a cutter. As particles from a grinder may contaminate the surface of the sample, a lathe or milling machine is used (not a grinder) to cut soft samples such as white metal. If trace elements are not being investigated, a grinder or belt sander can be used. However, to minimize contamination, the grinding wheel or belt should be changed for each sample. Samples excised from semi-complete or complete products must be at least 12 mm in diameter. Small rod-shaped samples can be analyzed using special equipment.
-
product
On-board Emissions Measurement System
OBS-ONE PM unit
OBS-ONE PM unit is the industry-leading on-board Particulate Matter (PM) measurement system. It collects PM on a filter paper, using a partial flow gravimetric sampling method, while simultaneously measuring real-time PM. A key feature of this design is the use of a venturi flow meter which enables reliable proportional sampling and accurate exhaust gas flow measurement under transient flow conditions. Combine the GAS unit and PM unit to perform certification tests on heavy duty and non-road vehicles.
-
product
Evaporative Emissions Testing
GASERA ONE SHED
Evaporative losses from the fuel system are tested for vehicle certification. GASERA ONE SHED allows direct monitoring of evaporative emissions as part of the qualification testing procedures for vehicles. The GASERA ONE SHED’s photoacoustic technique is approved by the Environmental Protection Agency (EPA) and the California Air Resources Board (CARB).
-
product
Sound Level Meter for Automotive – Car Noise Emission Inspection
HD2010MCTC
The level of noise produced by vehicles shall comply with standards prescribed by international regulations. During car inspections, horns and exhaust devices must be in good condition and comply with the requirements.
-
product
CEMS II E Continuous Emission Monitoring System
CEMS II e takes away the manual configuration and settings adjustments from your day-to-day emissions measurements. A fully automated continuous emission monitoring system CEMS II e is TÜV and MCERTS certified solution (QAL1) to offer environmental compliance. This emission monitoring system is suitable for measuring pollutants continuously from hot, wet and corrosive gas streams in various industrial processes, such as powerplants, waste incineration, cement plants and beyond.
-
product
Combination Emission Tester for the Measurement of Petrol- and Diesel-Powered Vehicles
MCT / MAHA COMBI TESTER | VP 135224
Maschinenbau Haldenwang GmbH & Co. KG.
The combination tester is designed for the measurement of petrol- and diesel-powered vehicles. In addition, low weight, compact design and short warm-up time ensure easy handling.
-
product
Hardware Enabled SaaS Solution Quantifying Methane Emissions
MethaneTrack™
NevadaNano’s MethaneTrack™ is a low cost network of rugged monitoring points to measure methane emissions and report leak location and size to the operator. Utilizing an Industrial IoT (IIoT) network to detect methane in the air, MethaneTrack™ detects fugitive and operational emissions from a site and immediately alerts the operator of the location and volume of the emissions, facilitating rapid response and repair. Autonomous, continuous monitoring enables up to 99% reduction in emissions while reducing operational costs and boosting profits.
-
product
520nm Green Direct Emission Laser Diode Modules
The Optoelectronics Company Ltd
Custom lasing wavelengths, from 405 nm to 852 nm, output power options and laser engraving are available to your specifications. Both standard and custom configurations provide OEMs, end-users and systems integrators with complete cost-effective laser solutions.
-
product
Total Reduced Sulfur System
ML670
The ML®670 Total Reduced Sulfur (TRS) system provides an accurate and convenient method of measuring Total Reduced Sulfur required for Emission Monitoring. The TRS system uses our specially designed TRS Dilution Sampling System combined with the T-Series® TRS analyzer to provide reliable TRS measurement. This system can be configured as an Open Architecture Design for ease of maintenance.
-
product
Long Focal Length Spectrometer
1000M Series
The M Series II monochromators are the large focal length monochromators of choice for the most demanding spectroscopy applications such as Raman, Plasma Emission, LIBS and others. With a spectral resolution down to 0.006 nm and an optional dual automated entrance and exit ports, the M Series II monochromators are the most versatile spectrometers in their market space. These monochromators also benefit from the highest quality of gratings, also designed and manufactured by HORIBA. The M Series is the ultimate spectrometer for ultra-high spectral resolution down to 0.006 nm.
-
product
Zero Emission Cabinets
A zero emission cabinet is connected to the exhaust extration system of the building and prevents exhaust gases from escaping into the building.VLT offers several different zero-emission cabinets for use with emission and diesel smoke analysers. They can be connected to your exhaust extraction system. Mandatory in some countries.
-
product
Test Automation System for Emission Testing
STARS VETS
STARS VETS is a Vehicle Emission Test System application available with the STARS Automation platform for chassis, engine and powertrain dynamometers. The application provides test cycle execution, emissions equipment control, results calculation and reporting in compliance with the different legislative standards throughout the global regions. Its flexible design offers a wide range a customization, and it addresses the various requirements for R&D, COP and certification testing.
-
product
Gas & Emissions Analyzer
Si-CA 8500
Accurate, reliable, robust & fast, the Si-CA 8500 Combustion Analyzer is the most powerful and advanced portable emissions analyzer on the market. Complete portable tool for emissions level monitoring of boilers, engines, and other combustion equipment, this emissions monitoring device can boast as many as 9 gas sensors, detecting one of the widest spectra of gases: O2, CO, NO, NO2, SO2, CO2, CxHy, High CO, VOCs and H2S.
-
product
Technical Measurement & Consultation Services
Pulsed EMI, Emission, to radiated immunity testing. The highest level of testing and measurement technique and solution know-how are sure to be of service to you.
-
product
OES Spectrometers
OES Spectrometers (Optical Emission Spectrometers for OEMs) optimized for SEMICON applications including plasma monitoring/end-point detection and reflectometry (with the addition of a flash lamp). The OES-Star features unmatched throughput and SNR, spectral coverage and < 1 nm resolution). Our new OES Family, OES-Star, VS70-MC and InVizU all include our latest “Multi-Communications interface” electronics (MC= EtherCAT, Ethernet, USB-2). The Invizu integrates both a linear CMOS sensor for UV-VIS and a TE-Cooled INGAAS sensor, which extends the spectral coverage to 1700 nm.
-
product
Portable Emission Analyzers
Portable Emission Analyzers are especially useful for, auto repairs, inspections, safety checks, and general engine tuning. Simply insert a probe into the exhaust pipe and press a key to initiate measurements. Readings appear on a back-lit liquid-crystal display on the front of the analyzer.
-
product
Emission Monitoring Systems
Gasmet’s emission monitoring systems set the standard for accurate, reliable, and cost-effective gas analysis. Our state-of-the-art solutions are designed to provide precise measurements of gaseous emissions, making compliance with environmental regulations seamless. With a focus on continuous emission monitoring systems (CEMS), we deliver innovative technology that balances sensitivity, durability, and affordability. Our products are fully TÜV and MCERTS-certified, ensuring world-class quality and performance. Trusted globally, our emission monitoring solutions are the future of gas analysis, empowering industries to meet stricter environmental requirements effortlessly.
-
product
Emissions Test System
PC-114
Perform Radiated & Conducted EMI pre-compliance testing at your facility up to 1 GHz. Com-Power PC-114 EMI emissions test system is a ideal solution performing pre-compliance EMC testing from 9 kHz - 1 GHz.. It has essential equipment needed for radiated and conducted EMI emissions measurements. The system includes a spectrum analyzer, antennas, near field probes, a preamplifier, LISN and a non conductive antenna tripod. Pre-compliance testing in EMC is a commonly used term not easy to define. In general, it implies testing done prior to formal testing for legal compliance. Formal legal compliance is performed at a facility designed and equipped with test instrumentation that is fully compliant with the applicable EMC standards. Such facility and instrumentation is capital intensive and can be expensive even to rent and not easily available. Compliance testing is performed per exacting requirements of the Standards and other reference documents adhering to the test methods and last detail. In addition, the test facility may require to be accredited by an accreditation body such as NVLAP, A2LA. Often it is desirable to know prior to compliance testing at such facility, whether a product is close to compliance and also how close. Pre-compliance testing is specially useful for specifications such as FCC, Part 15, EN 55022 or EN 55011 (CISPR 22 or CISPR11). Pre-compliance testing usually means using the full compliance methods but making a few educated compromises in use of site or equipment to reduce costs and testing time. Here are some benefits of pre-compliance testing.
-
product
Real-Time Online Monitoring to Detect and Analyze Potential Partial Discharge (PD) Signals and Insulation Faults using UHF, AE, and HFCT
PDMonitor
Power Monitoring and Diagnostic Technology Ltd.
The PDMonitor, which utilizes Ultra High Frequency (UHF), Acoustic Emission (AE) and High Frequency Current Transformer (HFCT) sensors and is designed to conduct real time online monitoring to detect and analyze potential Partial Discharge (PD) signals and insulation faults before they lead to breakdown or catastrophic failure in power assets. The system provides the developing trend of the PD, when occurring, as alarms in real time, thus helping to predict the insulation degradation status of the asset, prevent sudden accidents, and provide an effective database for Condition-Based Maintenance (CBM) of power assets.
-
product
Software
Driver Module
Consistent Driver module for various target Environments to perform Emission homologation, certification, RDE, range, customer FE tests with human drive styles for all kinds of cycles
-
product
EMC Testing Knowledge & Equipment
Creating, delivering, installing, and training on EMC test systems; RF Immunity systems, RF Radiated and Conducted Emissions systems, Conducted Immunity and Pre-compliant EMC systems.
-
product
1GHz EMC Emissions Analyser
SA1002
The SA1002 provides a high performance capability to measure the EMC compliance of your products. It covers the conducted emission and radiated emission bands to 1GHz, as required by most EMC standards. The included software is Windows compatible and simple to use. This powerful system automatically sets the analyser parameters to suit the test to be performed. Standard limits are available from simple pull-down menu. Results can be directly compared against these limits for easy checks on compliance status.
-
product
Vehicle Emissions Laboratory
Trialon’s Vehicle Emissions state of the art testing facility is located in the heart of the Detroit Metro area. Our facility is equipped with the essential emissions equipment to simulate real driving conditions to meet the needs of national regulations. The test facility is staffed with talented technicians and engineers with over 50 year of combined experience.
-
product
Plasma Emission Detectors for Gas Chromatographs
Our patented Plasma Emission Detector is available for integration into any gas chromatography system or installation. It has been designed for ‘plug and play’ installation and to allow for analysis of impurities from PPB to % levels using either capillary or packed columns.
-
product
General Purpose Acoustic Emissions Detector
BW-AED-500
The input can range from 40Hz to 160KHz from sensors with similar ranges. The output can be delivered to a speaker, oscilloscope and an LED for threshold detections ranging from 0-Infinite. The power supply features regulated +5VDC, -5VDC, +12VDC, +15VDC, -15VDC and +/- unregulated 20VDC. Voltage input of 110VAC @ 60Hz or 220VAC @ 50Hz.
-
product
Endpoint / Chamber Health Monitor based on Optical Emission Spectroscopy and MWL Interferometry
EV 2.0 Series
To address new requirements in Semiconductor, lighting devices, automotive components, flat panels, MEMS sensors, memory chips, and logic electronics processed in the industry using dry etch, cleaning and (PE)CVD, HORIBA has introduced a unique generation of sensor dedicated to Advanced Endpoint Control, Fault Detection and Chamber Health Monitoring.
-
product
EST-200 Emission Safety Test System For Toys
Hangzhou Everfine Photo-E-Info Co., LTD
The system can test the radiation intensity, irradiance, light color expansion angle, peak wavelength, dominant wavelength, bandwidth, etc. of various toy light emitting devices. The measurement conditions meet the CIE127 standard, and the test report meets the ENIEC62115:2020 standa
-
product
Portable Emissions Analysers
Portable Automated Monitoring Systems, P-AMS or PEMS, such as Protea’s FTIR and TDL analysers allow for a wide range of industrial pollutants to be measured periodically or as a back-up to existing CEM systems.
-
product
Chemical Analysis and Corrosion Testing
Performing chemical analysis of metal alloys including both ferrous and non-ferrous alloys.Chemical analysis involves determining the chemical constituents of metals and related materials.An industry leader and co-operating laboratory for qualifying Calibration Standards for Chemical Analysis.Our chemical laboratory processes include Spectroscopy – Optical Emission Inductively Coupled Plasma, gas analysers, wet chemical, Intercrystalline/ Intergranular Corrosion (including G28, G48 etc).
-
product
On-board Emissions Measurement System
OBS-ONE PN Unit
The OBS-ONE PN unit is an on-board emissions measurement system for analyzing the solid particle number concentration within the specified particle size range under real-world driving conditions. The unit uses a condensation particle counter which is recommended principle by the Particle Measurement Programme (PMP), one of working groups affiliated with UNECE.The PN unit combines with the GAS unit to measure the specified exhaust gas components, along with the exhaust gas flow rate, the GPS position, and the atmospheric conditions (temperature, humidity, pressure).