Frequency Sources
A stable oscillator used for frequency calibration or reference. (atis.org)
-
Product
PXIe-4139, ±60 V, ±3 A DC, ±10 A Pulsed, 20 W DC, 100 fA Precision System PXI Source Measure Unit
782856-02
Source Measure Unit
PXIe, ±60 V, ±3 A DC, ±10 A Pulsed, 20 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4139 is a high-precision, system source measure unit (SMU) that features 4-quadrant operation and sources up to 20 W of DC power. This module features analog-to-digital … converters that help you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. You can use the PXIe-4139 for applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.
-
Product
PXIe-4139 , ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit
782856-03
Source Measure Unit
PXIe, ±60 V, ±3 A DC, ±10 A Pulsed, 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4139 is a high-precision, system source measure unit (SMU) that features 4-quadrant operation and sources up to 40 W of DC power. This module features analog-to-digital converters that help you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. You can use the PXIe-4139 for applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.
-
Product
PXI/PXIe Source Measure Unit Family
PXS(e)840x
Source Measure Unit
The PXS840x PXI SMU family is a high-speed, 4-quadrant source measure unit. Carry out measurements directly on the DUT with the integrated CMU and VMU.
-
Product
Noise Source, 1 GHz up to 40 GHz
346CK40
Noise Source
The Keysight 346CK40 is the ideal companion to Keysight´s noise figure solutions when working on high frequency applications. Since it is broadband (1 GHz to 40 GHz), it eliminates the necessity for several sources at different frequency bands. The low SWR of the noise source greatly reduces measurement uncertainty, which are commonly reflections of the test signals. This is a coaxial noise source with a 2.4 mm coaxial connector. ENR typically 14 dB at 1 GHz, decreasing to 5 dB at 40 GHz (typical).
-
Product
PXIe-4138, 60 V, 3 A System PXI Source Measure Unit
782856-01
Source Measure Unit
±60 V, 3 A System PXI Source Measure Unit—The PXIe‑4138 system source measure unit (SMU) delivers high power, precision, and speed. It is ideal for a broad range of applications including manufacturing test; board-level test; lab characterization with devices such as integrated circuits (ICs), power management integrated circuits (PMICs), and radio frequency integrated circuits (RFICs); and discrete devices including LEDs and optical transceivers. The PXIe‑4138 features 4-quadrant operation. The PXIe‑4138 is a hardware-timed instrument with a high-speed sequencing engine for synchronizing acquisitions between multiple SMUs. The module supports direct DMA streaming between the host PC and SMU, so you can stream large waveforms and measurement data at the full update rate and sample rate of the instrument.
-
Product
NI-9326, 6-Channel, 150 V, 128 kHz C Series Frequency Input Module
786999-02
Frequency Input Module
6-Channel, 150 V, 128 kHz C Series Frequency Input Module - The NI-9326 is a channel-to-channel isolated frequency input module for CompactDAQ and CompactRIO systems. This module includes six differential input channels with a 0 Vrms to 150 Vrms input range. The NI-9326 also features configurable thresholds for connection to a variety of variable reluctance sensors, single channel encoders, and hall-effect sensors. You can use the included embedded counters to perform frequency measurements or edge-counting for tracking total counts on a periodic signal. Additionally, the NI-9326 supports configurable Butterworth filters to help you perform low-noise frequency measurements.
-
Product
Standard 3.74 (106.00) - 14.35 (407.00) High Frequency Probe
K-50B-QG-75
High Frequency Probe
Nominal Impedance (Ohms): 50Bandwidth @ -1dB (GHz): 12.00Return Loss @ -20dB (GHz): 3.00Test Center (mil): 550Test Center (mm): 13.97Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 1,575Overall Length (mm): 40.00
-
Product
Noise Source, 10 MHz to 18 GHz, nominal ENR 15 dB
346B
Noise Source
The Keysight 346B noise source is the ideal companion to Keysight's noise figure solutions. Since it is broadband (10 MHz to 18 GHz), it eliminates the necessity for several sources at different frequency bands. The low SWR of the noise source reduces a major source of measurement uncertainty; reflections of test signals. The 346B's high ENR, low SWR, and variety of connectors make it a general-purpose noise source. Add special option H01 for high ENR (21 dB typical) to measure high noise figure devices, or option H42 for measuring Direct Broadcast Satellite (DBS) low noise block converters.
-
Product
10-Ch. 0… 5V 400mA Isolated
YAVAP955
Programmable Voltage Source
The YAV board AP955 contents 10 CAN Bus programmable bipolar Isolated precision and low noise 0 to 5VDC voltage sources up to 400mA output, with Tripaddle VPC connector.
-
Product
PXIe-4147, 4-Channel, ±8 V, 3 A Precision PXIe Source Measure Unit
786888-01
Source Measure Unit
PXIe, 4-Channel, ±8 V, 3 A Precision PXI Source Measure Unit - The PXIe-4147 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote four-wire sensing for accurate measurements. The sample rate of the PXIe-4147 can reduce measurement times, capture transient device characteristics, and help you perform current-voltage (I-V) characterization of devices-under-test (DUTs). With a high-speed sequencing engine, you can synchronize SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4147 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40A-024
High Frequency Probe
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 225 (5.72) including travel of probes
-
Product
Optical Switches
Optical Source
Fast and reliable optical switches to streamline your test procedures. Can be customized with a wide range of switch configurations, fiber types and connectors.
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40G-021
High Frequency Probe
Your product description goes here.
-
Product
Source Measurement Unit
DPS16
Source Measure Unit
The DPS16 offers high voltage DPS in a compact, 3U PXI form factor. The DPS16 supports 0V to +4V 0.3A or 0V to 12V 25.6mA with FVMI, FVMV, FIMV, FIMI modes. 16 channel can be ganged to support high current driving.
-
Product
PXIe 5-channel Source/Measure Unit, 500 kSa/s, 100 pA, 30 V, 500 mA
M9614A
Source Measure Unit
The Keysight M9614A is a PXIe five-channel source / measure unit (SMU). It supports accurate measurement up to 30 V / 500 mA with resolution down to 6 μV / 100 pA.
-
Product
Tunable Laser Source - PXI
Laser 1000 Series
Laser Source
The Laser 1000 Series PXIe module is a Continuous Wave (CW), tunable laser source offering high-power output, narrow 100kHz linewidth and 0.01pm resolution tunability.With seamless PXI integration, it can be easily integrated into new or existing PXI test setups. Save space, lower your costs and improve testing efficiency while delivering reliable and repeatable results in production or research environments.
-
Product
Laser Source Simulator
MT1888 Series
Laser Source
The MT1888 products are state-of-the-art Laser Source/Spot Simulators (LSS) used for the testing of laser guided munitions such as the Hellfire & Hellfire II missiles, Paveway, and the AGM-65E Laser Maverick missile.
-
Product
DC - 12 GHz High Efficiency GaAs HBT MMIC Divide by 4 Prescaler
HMMC-3024
Frequency Divider
The HMMC-3024 is a DC - 12 GHz divide by four pre scaler designed for use in high frequency communications, microwave instrumentation, and EW radar systems where low phase-noise PLL control circuitry or broadband frequency translation is required.
-
Product
Performance AC Power Source, 750 VA, 300 V, 6.5 A
6812C
Power Source Analyzer
Maximize your investment with five instruments in one device Increase your productivity with extensive built-in power measurement capabilities Flexible IO: LAN/LXI Core, USB and GPIB Lower your cost of ownership with global support & the longest standard warranty in the industry
-
Product
Two-Quadrant SMU For Battery Drain Analysis, 20 V
N6781A
Source Measure Unit
The Keysight N6781A is a source / measure unit (SMU) designed specifically for the task of battery drain analysis. Whether the device under test (DUT) is an eBook reader, MP3 player, mobile phone, or pacemaker, the N6781A’s seamless measurement ranging, programmable output resistance, and auxiliary DVM combine the best set of advanced features on the market for battery drain analysis. When used with the 14585A Control and Analysis software, the N6781A becomes an even more powerful battery drain analysis solution, offering additional insights into your measurements. Learn more about the 14585A Control and Analysis software.
-
Product
PXIe-4137, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit
783761-02
Source Measure Unit
PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 100 fA Precision System PXI Source Measure Unit - The PXIe-4137 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4137 is ideal for a broad range of applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers
-
Product
PXIe-4145, 4-Channel, ±6 V, 500 mA Precision PXI Source Measure Unit
782435-01
Source Measure Unit
PXIe, 4-Channel, ±6 V, 500 mA Precision PXI Source Measure Unit - The PXIe-4145 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4 wire) sensing for accurate measurements. The fast sample rate of the PXIe-4145 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4145 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
-
Product
USB Modular Source Measure Unit
U2722A
Source Measure Unit
The U2722A USB Modular Source Measure Unit is a 3-channel 20V/120mA that can operate in a 4-quadrant operation. The channels could be connected in series or in parallel to achieve up to 60 V/360 mA. It uses the common non-proprietary standard high-speed USB 2.0 interface that provides ease of connectivity allowing users to set up and configure their tests swiftly with its plug and play feature.
-
Product
USB Modular Source Measure Unit
U2723A
Source Measure Unit
The 3-channel 20V/120mA module can operate in a 4-quadrant operation. The channels could be connected in series or in parallel to achieve up to 60 V/360 mA. It uses the common non-proprietary standard high-speed USB 2.0 interface that provides ease of connectivity allowing users to set up and configure their tests swiftly with its plug and play feature.
-
Product
120 GHz Frequency Extender
N5295AX01
Frequency Extender
The N5295AX01 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.
-
Product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40B-012
High Frequency Probe
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
Product
120 GHz Frequency Extender, Pulsed DC Bias
N5295AX52
Frequency Extender
The N5295AX52 is a compact and broadband frequency extender with built-in pulsed bias-tee and provides 10 MHz to 120 GHz single-sweep measurements with N5292A test set controller systemized with a PNA/PNA-X B vector network analyzer.
-
Product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50B-S
High Frequency Probe
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
Product
PXIe-4141, 4-Channel, ±10 V, 100 mA, Precision PXI Source Measure Unit
781743-01
Source Measure Unit
PXIe, 4-Channel, ±10 V, 100 mA, Precision PXI Source Measure Unit - The PXIe-4141 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4 wire) sensing for accurate measurements. The fast sample rate of the PXIe-4141 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4141 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
-
Product
110 GHz Frequency Extender
N5293AX53
Frequency Extender
The N5293AX53 modules are compact lightweight modules designed to interface to the N5292A test set controller that is driven with a PNA/PNA-X B model vector network analyzer.





























