Leakage Current Clamps
Measure low current emf surrounding a conductor.
-
Product
PXI/PXIe Wide Current Range Multiplexer Module, Dual 3-Channel, 4-Pole
40-514-101
Multiplexer Module
The 40-514-101 (PXI) and 42-514-101 (PXIe) are low density multiplexers in dual 3-channel, 4-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
Product
Current Probe For Non-Intrusive Measurement Of AC, DC, And Waveform Currents
CP 305
-
The CP 305 current probe has been designed for use with oscilloscopes respectively for accurate, non-intrusive measurement of AC, DC and complex waveform currents.Using advanced Hall Effect technology the CP 305 can measure currents accurately up to 450A peak over the frequency range of DC to 20 kHz.
-
Product
TightSight™ Clamp Meter, 660A AC/DC W/TRMS
61-765
-
*TightSight™ bottom display*Tapered jaws with hook tip*True RMS current and voltage*AC/DC voltage*Audible continuity*High frequency rejection**Peak hold*Max/min hold*Data hold*Selectable audible and visual alerts when potentially hazardous voltages are detected at the probe terminals*Selectable auto power off*Backlit display*Low battery indicator*Reads accurately on noisy electrical circuits
-
Product
Rogowski Coil Current ProbesTOP
-
*Switching current waveform and pulse response characteristics of power devices*Current measurements of inverter system*AC current measurements (at large DC offset)*Impulse high current measurements*Bus Bar high current measurements
-
Product
Current Probes
-
Innovative DC to 5MHz "positional" current probe capable of measuring currents in PCB tracks, component legs etc. without the need to break the connection or surround the conductor.
-
Product
Inductive Sensors (eddy Current)
eddyNCDT
-
Inductive sensors from Micro-Epsilon are based on the eddy current principle and designed for non-contact measurement of displacement, distance, position, oscillation and vibrations. They are particularly suitable when high precision is required in harsh industrial environments (pressure, dirt, temperature). Inductive sensors from Micro-Epsilon offer extremely precise measurements where sub-micron accuracy is required.
-
Product
Duct Air Leakage Tester
6900
-
Kanomax has developed the most advanced Duct Air Leakage Tester (DALT) for commercial duct systems. It’s designed to be simple to use, accurate, and extremely convenient. The instrument provides step-by-step duct leakage test configuration and automated leakage testing based on the SMACNA HVAC Air Duct Leakage Test Manual, and is accurate to ±2.5% of reading. Though built tough with an on-board, powerful motor, the DALT 6900 is very easy to transport on its pneumatic tires and leaves little to no footprint on the job site.
-
Product
High Accuracy 100 Amp Current Probe
HA100
-
The HA100 is a compact clamp-on current probe for smaller loads where compact size is important. Its measurement range is from 0.1 to 100 amps AC and is very small which is ideal for locking inside a crowded electrical panel during monitoring.
-
Product
Enclosure, G12x, Front Mount, 4 Cable Clamps, 12" Depth
410112856
Enclosure
Enclosure, G12x, Front Mount, Hinged Cover, 4 Cable Clamps, 12" DepthIncludes hinged cover and 4 cable clamps for discrete wiring. When cable clamps are open- stiffener bar can be removed for installing or removing cables without unplugging patchcords from assembly.Housing: Material = .06" Aluminum, Finish = Powder Coat BlackCover(s)/Access Panel(s): Material = .12" Aluminum, Finish = Black Anodize
-
Product
Primary Current Injection Test Set
T 2000
-
T 2000 is a portable current transformer test set which allows to perform many different measurements such as saturation, ratio and polarity tests and CT winding resistance test. Substation maintenance and commissioning test equipment, T 2000 is extremely appreciated by electrical engineers for its high accuracy and portability.
-
Product
NI-9253, 50 kS/s/ch, ±20 mA, 24-Bit, 8-Channel C Series Current Input Module
785989-01
Current Input Module
50 kS/s/ch, ±20 mA, 24-Bit, 8-Channel C Series Current Input Module - The NI-9253 is an 8-channel analog input module for ComapctDAQ and CompactRIO systems. Each channel provides a ±20 mA input range and 24 bits of resolution at a 50 kS/s sample rate. The NI-9253 has several diagnostic features to ensure your system is operating nominally at all times with open channel detection, power supply detection, and configurable thresholds. The NI-9253 has eight LEDs to indicate the status of each channel and the power supply so that a user in the field can easily validate that the system is operating normally. The NI-9253 also features a number of programmable hardware filters. By choosing the specific Butterworth and comb filters for your application, you can significantly reduce the noise in your system.
-
Product
Impulse Semiconductor High Current Integrated
Transmission Line Pulse Test System
-
The Impulse Semiconductor High Current Transmission Line Pulse (TLP) test system is the tool of choice for extracting ESD parameters for transient protection devices in a package, or at wafer level. With accuracy better than 100 milliohms at 40 amps peak current, the Impulse high current TLP is specially tailored to the needs of today's ESD device designers who must accurately measure low values dynamic resistance irrespective of breakdown voltage.
-
Product
OEM Current Input0 to 20mA
TGPR-0800
-
A current input data logger that is supplied uncased so that it can be built into custom applications.The TGPR-0800 can be used to record the output from a number of industry standard 4-20mA sensors. Common applications include pressure and flow rate monitoring.
-
Product
High AC Current Capacitors
-
HK Film Capacitors offer a selection of High AC Current Capacitors ( continuous duty) with Temperature up to +105C
-
Product
AC/DC CAT IV 600 A TRMS Navigator Clamp Meter
ACDC-52NAV
-
The ACDC-52NAV clamp-on power meter is the ideal choice for jobs that require AC/DC current measurements to 600 A, AC/DC voltage to 1000 V and wide jaws to accommodate large conductors.
-
Product
30 A, 10 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 3 Meter Cable
CP030-3M
-
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Product
Clamp type DC Current Sensor/for DC Leakage Current Measurements
DCZCT-18S
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Compact size, General purpose*DC leakage current measurements
-
Product
Hipot Current Calibration Load Resistors
HPRS-HIPOT-LOAD
-
The IET HPRS-Hipot-Load is an excellent replacement for the Fluke 5320A-Load Hipot current calibration load resistors. The IET high power resistive load can be used with the Fluke 5320A Multifunction Electrical Tester Calibrator or standalone. It provides a high power and high voltage load to various hipot tester to create the leakage current needed to calibrate various manufactures hipot testers.
-
Product
ECT / ECA Eddy Current Flaw Detector
EVi
-
United Western Technologies Corp
The EVi works directly with the EddyView Family of probes and accessories. UniWest’s unmatched selection of standard and advanced display features set a new standard for flexibility of applications, ease of use, interpretation of data and overall operator accuracy. The key to the EVi’s ground-breaking performance is the display of a visual image of the surface area under inspection alongside the customary and selectable eddy current signal displays (impedance plane, A-scan or strip charts). The EVi provides a high precision, easily readable display of surface conditions enabling improved interpretation of data while giving more accurate discernment of cracks, pits, gouges and fretting.
-
Product
PXI/PXIe Battery Simulator Module, 4-Channel, V/I Readback, Simplified Current Sink, 750 V Isolation
41-752A-912
Battery Simulator
Targeting EV, automotive, aerospace, energy storage and electric aircraft applications, the new battery simulator modules occupy a single PXI slot. These 4-channel battery simulators are capable of supplying up to 7 V and 300 mA per channel. The channels are fully isolated from ground and from each other, allowing series connection to simulate batteries in a stacked architecture.
-
Product
Rogowski AC Current Probe
RCP500
-
Shenzhen Micsig Instruments Co., Ltd.
Adopts the Rogowski coil current measurement system: within the range, the output signal of the system and the current signal to be measured are always linear, so the accuracy will not change with the current; The RCP500 measures AC current up to 500A pk, minimum to 200mA pk, with bandwidth ranging from 15Hz to 300KHz, 1% accuracy, and has less than 2mV noise. Directly powered by Micsig UPI interface, realise auto scaling setup,
-
Product
Interconnect Adapter, C-Size, Single Slot, 2 Module Positions, Clamp Style
510109179
Interconnect Adapter
Interconnect Adapter, C-Size, Single Slot, 2 Module Positions, Clamp Style
-
Product
Hand Held Probe Type Eddy Current Sheet Resistance/resistivity Measurement Instrument
EC-80P (Portable)
-
*Auto-measurement start by probe head contacting to sample*3 measurement modes for wafer resistivity, bulk resistivity and sheet resistance*Easy set up to measurement condition by JOG dial*5 types of model for each measuring range*Resistivity probe can be changed by sample’s resistivity range
-
Product
Frequency to Current Converter
DAT4540R
-
The Frequency to Current converter DAT4540R is a signal conditioning din rail mount converter which converts a pulse input to an analog output equal to the set range which is selectable from 0.1 Hz up to 20 KHz. The DAT4540R also provides 2 relay outputs and a transistor output. The input can be from a Tacho, TTL, PNP transistor or from any Namur standard. The DAT4540R provides a Voltage or Current output that is isolated from the power supply and input.
-
Product
Low Level DC Current Data Logger
Process101A
-
The Process101A is one of MadgeTech's newest data loggers. It is part of a new series of low cost, state-of-the-art data logging devices. MadgeTech has taken the lead in offering the most advanced, low cost, battery powered data loggers in the world today.
-
Product
16 SE Or 8 Diff. Input Channels, 8 Analog Current Output Channels, PCI Express
APCIE-3121-16-8C
-
Input range:?± 10 V, 0-10 V software programmable0-5 V, ± 5 V, 0-2 V, ± 2 V, 0-1 V, ± 1 V (gain)0-20 mA (option) ? software-programmable amplifier:PGA x1, x2, x5, x10 ? Conversion triggered through software,scan, timer, external event ? Onboard FIFO buffering for 256 analog values ? Data exchange through 16-bit I/Oor 32-bit memory (PCI DMA) ? Sequence RAM ? Overvoltage protection ? input filter: 160 kHz
-
Product
Self-testing Static Grounding Clamp
Bond-Rite CLAMP
-
In many branches of the process industries, fires and explosions can result from electrostatic discharge in hazardous areas. Even relatively small sparks have sufficient energy to ignite many flammable vapours, gases and even airborne dusts. In situations, where this risk exists, static grounding (earthing) and bonding clamps are required wherever mobile or portable conductive plant items (such as drums and vessels etc) are used.
-
Product
Power Clamp Meters
-
TES Electrical Electronic Corp.
Communication with PC. 4000 continuity point data logger, 25 point manual data logger. True power/ apparent Power/ Power Fractor Measurement. True RMS. V,A,W cap Ind, phase indicator.
-
Product
AC/DC Current Probe, 100 MHz, 15A
N2893A
Oscilloscope Probe
The Keysight N2893A is a 100 MHz bandwidth, active current probe for InfiniiVision and Infiniium oscilloscopes. The probe features flat bandwidth (DC-100MHz), low noise(<2.5 mA rms) and low circuit insertion loss. Auto demagnetization (degauss) and calibration removes any residual magnetism and unwanted DC offset in the probe. The probe is powered directly by the InfiniiVision and Infiniium Autoprobe interface, eliminating the need for an additional power supply.





























