Multiplexers
Combine multiple signals into one signal.
See Also: Switching, Switching Matrix, High Voltage Switching, Switching Matrices, General Purpose Switch
-
product
PXI/PXIe MEMS Optical MUX, 4-Channel, Multi-Mode, 50/125 Fiber, ST Connectors, With Interlock
42-850A-514-M50-HI
The 40/42-850A-514-M50-HI is a PXI/PXIe 4-channel multiplexer with ST connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
product
PXI/PXIe Microwave Multiplexer, Dual SP6T, 40 GHz, 50 Ω, SMA-2.9, Remote Mount, Failsafe
42-784B-042-E
The 40-784B-042-E (PXI) and 42-784B-042-E (PXIe) are dual failsafe SP6T 40 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
product
PXI/PXIe Wide Current Range Multiplexer Module, Dual 3-Channel, 4-Pole
40-514-101
The 40-514-101 (PXI) and 42-514-101 (PXIe) are low density multiplexers in dual 3-channel, 4-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
product
LXI Microwave Multiplexer, 50Ω 4-Channel 10-Bank 26.5GHz SMA
60-802-310
The 60-802-310 is a 4-channel, 10-bank RF multiplexer suitable for switching 50Ω signals up to 26.5GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
product
PXI-2584 , 12-Channel, 600 V, 1-Wire PXI Multiplexer Switch Module
778572-84
12-Channel, 600 V, 1-Wire PXI Multiplexer Switch Module —The PXI‑2584 is a high‐voltage PXI multiplexer switch module that is ideal for fuel cell and battery stack applications. The reed relays in the PXI‑2584 ensure longer lifetimes and faster actuation times for test equipment. It also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.
-
product
PXI/PXIe Microwave Multiplexer, Dual SP4T, 50 GHz, 50 Ω, SMA-2.4, Terminated, Failsafe
42-785C-452-T
The 40-785C-452-T (PXI) and 42-785C-452-T (PXIe) are dual failsafe SP4T 50 GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
product
PXI/PXIe MEMS Optical MUX, 8-Channel, Multi-Mode, 50/125 Fiber, MU Connectors
42-852A-318-M50
The 40/42-852A-318-M50 is a PXI/PXIe 8-channel multiplexer with MU (mini SC) connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules.
-
product
PXI High Density Mux 99 Channel 1 pole
40-670A-021-99/1
The 40-670A series of very high density multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).
-
product
PXI/PXIe High Voltage Multiplexer, Triple 7-Channel, 1-Pole
40-321-102-HI
The 40-321-102-HI (PXI) and 42-321-102-HI (PXIe) are triple 7-channel 1-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
product
PXI/PXIe Microwave Multiplexer, Dual SP4T, 40GHz, 50Ω, SMA-2.9, Remote Mount
40-785C-442-E
The 40-785C-442-E (PXI) and 42-785C-442-E (PXIe) are dual SP4T 40GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
product
PXI/PXIe Microwave Multiplexer, Dual SP4T, 18 GHz, 50 Ω, SMA, Failsafe
42-785C-422
The 40-785C-422 (PXI) and 42-785C-422 (PXIe) are dual failsafe SP4T 18 GHz unterminated microwave multiplexers. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
product
PXI/PXIe MEMS Optical MUX, 8-Channel, Multi-Mode, 62.5/125 Fiber
40-852A-318-M62.5
The 40/42-852A-318-M62.5 is a PXI/PXIe 8-channel multiplexer with MU (mini SC) connectors and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. They are also available with an optional hardware interlock which, when activated, will return all optical switches to their default unpowered state.
-
product
PXI Dual 2 x 2 Fibre Optic (M Mode) STM62.5
40-860-522-M62.5
Pickering PXI Fiber Optic MEMS Switching cards are available in many high density formats with a choice of 5 different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications. Fiber optic multiplexers create a signal path by redirecting the optical signal into a selected output fiber. This is achieved using Micro-Mechanical Mirrors driven by a highly precise mechanism and activated via an electrical control signal.
-
product
Analog Input Products
Analog input boards are useful for measuring variably changing conditions in the real world. When we want to measure these variably changing conditions, we need analog inputs to convert these changing real world conditions to changing electrical quantities. For example, monitoring the temperature inside a wood kiln, or the water pressure on the output of a pump, or the heart rate of a medical patient. In each of these cases, you can use one of our analog input devices to convert the electrical data from a sensor or transducer into binary data that can then be used by your computer. The device that converts this data is known as an analog to digital converter (abbreviated ADC, A/D, or A to D). An analog input is a measurable electrical signal with a defined range. The analog input changes continuously in a definable manner in relation to the measured property. This data is very useful for process monitoring, process control, or simple monitoring / data collection and acquisition. ACCES' analog input boards amplify and multiplex input signals from thermocouples, strain gauges, accelerometers, photo sensors, flowmeters, RTDs, thermistors, voltage sources, millivolt sources, and current sources, just to name a few.
-
product
PXI/PXIe MEMS Optical MUX, 8-Channel, Multi-Mode, 62.5/125 Fiber, FC/PC Connectors, With Interlock
42-852A-118-M62.5-HI
The 40/42-852A-118-M62.5-HI is a PXI/PXIe 8-channel multiplexer with FC/PC connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
product
LXI Microwave Multiplexer, SP4T, 13-Bank, 40GHz, 50Ω, SMA-2.92, Terminated
60-803-513
High performance RF multiplexer suitable for switching microwave signals up to 40GHz with automatic termination of unused signals
-
product
PXI 8-slot BRIC Power Multiplexer, 20-Channel, 12-Pole (7 Sub-cards)
40-571A-305
The 40-571A-305 is a 20-channel, 12-pole 3 Amp Power Multiplexer and is part of our BRIC family. The 40-571A range is designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing.
-
product
Analog Multiplexer Board
104-AIM-32
The 104-AIM-32 is an analog signal multiplexer conforming to the PC/104 standard. The card will multiplex and condition 16 differential or 32 single-ended analog signals before passing them to an analog-to-digital converter card like the 104-AIO12-8. A system may comprise one to seven of these cards in tandem with one 104-AIO12-8 A/D converter board. The 104-AIM-32 card may be used as part of a large data acquisition system. The 104-AIM-32A Kit consists of one 104-AIM-32 and one 12-bit 8-input A/D board.
-
product
LXI Microwave Multiplexer, 50Ω 4-Channel 14-Bank 6GHz SMA
60-802-014
The 60-802-014 is a 4-channel, 14-bank RF multiplexer suitable for switching 50Ω signals up to 6GHz. It is part of a range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for between 1 and 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
product
PXI Switch - 24-CH 2-Wire Multiplexer Module
PXI-7921
ADLINK PXI-7921 is a relay multiplexer which consists of 24 2-wire relays (DPDT, 2 Form C). As a multiplexer, the PXI-7921 provides 48x1 1-wire, 24x1 2-wire and 12x1 4-wire configurations. Users could choose one of the configurations by software. PXI-7921 typically connects one instrument, such as a DMM, a digitizer or a signal source, with many points which need measurement or excitation. The contact position of the relays can be changed either by direct software commands or by following the instructions previously stored in the on-board scan list. The scan list advances upon the trigger from external measurement devices, such as a DMM. The scan list could also advance when the scan-delay timer expires. In the PXI-7921, PXI trigger functions are supported and software programmable. Multiple modules can therefore be synchronized without additional field wiring.
-
product
PXI 5A Mux 4-Bank 11-Ch Isolated COM
40-651-013
This range of high density power multiplexer modules is suitable for switching inductive/capacitive loads up to 5A at 250VAC. It is available in the following 1-pole multiplexer formats: 1-bank 48-channel. 2-bank 24-channel. 4-bank 11-channel. 8-bank 5-channel.Connections are made via a front panel 50-way male D-type connector. Power multiplexer modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids.
-
product
PXI/PXIe Microwave Multiplexer, Single SP6T, 3GHz, 50Ω, N-Type, Terminated
40-785C-561-T
The 40-785C-561-T (PXI) and 42-785C-561-T (PXIe) are single SP6T 3GHz microwave multiplexers with automatic termination of unused signals. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
product
PXI/PXIe Microwave Multiplexer, Single SP6T, 6 GHz, 50 Ω, SMA, Remote Mount, Failsafe
42-784B-001-E
The 40-784B-001-E (PXI) and 42-784B-001-E (PXIe) are single failsafe SP6T 6 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
product
PXI/PXIe Microwave Multiplexer, Triple SP6T, 26.5 GHz, 50 Ω, SMA, Terminated, Remote Mount, Failsafe
42-785C-533-TE
The 40-785C-533-TE (PXI) and 42-785C-533-TE (PXIe) are triple failsafe SP6T 26.5 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
product
Single 2 Channel Fibre Optic Mux SC/PC
40-815-212
Pickering PXI Fiber Optic Multiplexers connect a single channel to one of two or four channels. They are available in single or dual multiplexer configurations supporting single-mode or multi-mode fiber. A wide choice of connectors types is available. The 40-810 multiplexer connects the optical channel by redirecting the optical signal into a selected output fiber.
-
product
LXI High Voltage Switching Multiplexer Plugin Module
65-231-909-HI
The 65-231-909-HI plug-in module is part of a scalable high voltage multiplexer platform that provides a high voltage switching solution with capability up to 9 kV.
-
product
PXI Very High Density Versatile 2 Amp Multiplexer
40-612A-002
The 40-612A Very High Density Versatile Multiplexer module features a wide range of software selectable switching configurations. It is especially useful where a number of high density multiplexers are required with the option of easily altering the channel count as a test system evolves. Typical applications include signal routing in ATE and data acquisition systems. The 40-612 module uses high quality electro-mechanical relays, connections are made via a front panel 160 pin DIN41612 connector. The module can be software configured into one of a large number of different multiplexer modes. Relays allow the multiplexer banks to be set in 1 or 2 pole mode and inter-bank switching enables the channel count to be increased up to a maximum of 128
-
product
PXI/PXIe Microwave Multiplexer, Dual SP4T, 6GHz, 50Ω, SMA
40-784B-102
The 40-784B-102 (PXI) and 42-784B-102 (PXIe) are dual SP4T 6GHz unterminated microwave multiplexers. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
product
16 A/D Channels (12.5 to 100.0 VDC FS); 16-bit SAR, 8 Chx2 A/D multiplexed
AD6
Module AD6 features 16 channels with up to 16-bit SAR A/D converters one per 8 channel multiplexed bank / 2 banks. The maximum programmable, expected full-scale range input for the AD6 module is 100.00, 50.00, 25.00 or 12.50 volts where range is -FS to +FS or 0 to FS VDC respectively. The A/D converters have programmable sample rates of up to 500 kHz / Aggregate per bank of 8 Channels.
-
product
PXI/PXIe RF Multiplexer, Triple 4-Channel, Terminated, 8GHz, 50Ω, SMA
42-882B-003
This multiplexer exhibits low VSWR characteristically over the full operating frequency range and consistent insertion loss characteristics. The use of solid state switches ensures a long service life with no wear out mechanism, making the 40/42-882B MUX ideal for ATE systems requiring frequent and fast operating RF switching.





























