Thermocouples
Thermocouples are junctions of two dissimilar metals that produce a very small voltage proportional to the temperature of the junction.
-
Product
LXI Low Thermal EMF Matrix 1-pole 56x33
60-510-001
Matrix Switch Module
The 60-510 is a high density 1-pole matrix module controlled via LXI. It has excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix. Typical applications include signal routing in ATE, selecting thermocouple inputs, switching amplifier gain circuits and high accuracy DC micro-volt measurements. Ruthenium reed switches are used because of their good low level switching capability. They also have a very long life with excellent contact resistance stability, minimal wetting current and low thermal offset.
-
Product
K Thermocouple Penetration Probe
TP657/1
-
“K” Type thermocouple flexible penetration probe. Tolerance according to IEC 60584-2 standard.
-
Product
Digital Thermometer with K Type Thermocouple Sensor
Model 300
-
this thermometer is a digital hermometer fr use with any K-type thermocouple as temperature sensor. temperature indication follows IEC584 temperature/voltage tables for K-type thermocouples.
-
Product
5 ½ Digits Dual-Display Digital Multimeters
SDM3055
-
The SIGLENT SDM3055-SC includes a multiplexer that provides multi-point measurement capabilities. The scanner features 12 multi-purpose + 4 current channels and supports the following measurement functions: DCV, ACV, DCI, ACI, 2WR, 4WR, CAP, FREQ, DIODE, CONT and TEMP (RTD and Thermocouple ). It provides a convenient and versatile solution for test applications that require multiple measurement points or signals and is an ideal tool for R&D burn-in and production testing.
-
Product
LXI Low Thermal EMF Matrix 1-pole 14x33
60-510-004
Matrix Switch Module
The 60-510 is a high density 1-pole matrix module controlled via LXI. It has excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix. Typical applications include signal routing in ATE, selecting thermocouple inputs, switching amplifier gain circuits and high accuracy DC micro-volt measurements. Ruthenium reed switches are used because of their good low level switching capability. They also have a very long life with excellent contact resistance stability, minimal wetting current and low thermal offset. The 60-510 is designed in accordance with the LXI Standard 1.4 and is supplied in a 2U high, full rack width case with 500mm depth.
-
Product
Mineral Insulated Thermocouples ANSI
-
Durable Mineral Insulated type thermocouples ANSI to suit a wide range of temperature measurement. Various probe types, lengths and diameters available.
-
Product
Tempical® Tester
H394
-
Precision Testing For: Thermal Switches, Chromel®-Alumel® Thermocouples, and Continuous-Wire Fire Detection Systems.
-
Product
LXI Low Thermal EMF Matrix 1-pole 28x33
60-510-003
Matrix Switch Module
The 60-510 is a high density 1-pole matrix module controlled via LXI. It has excellent thermal stability and substantially reduced thermal EMF figures when compared to a conventional switching matrix. Typical applications include signal routing in ATE, selecting thermocouple inputs, switching amplifier gain circuits and high accuracy DC micro-volt measurements. Ruthenium reed switches are used because of their good low level switching capability. They also have a very long life with excellent contact resistance stability, minimal wetting current and low thermal offset.
-
Product
Temperature And Humidity Data Loggers
-
These dataloggers are used to monitor and record temperature and/or humidity. Available in either single or multi channel inputs for thermocouple, RTD, thermistor, & infrared temperature sensors.
-
Product
Environmental Test Probe, Temperature
72-8364
-
Type K Surface Temperature Probe Surface probe is ideal for flat stationary surfaces such as molds, heating elements, integrated circuits, transistors and transformers. Very low sensor element mass enables fast response measurement time. Type K thermocouple temperature probes are commonly used with all types of industrial temperature controls and measurement equipment, and are compatible with Tenma handheld thermometers and digital multimeters that include temperature function. All are terminated with standard Type K plugs. See the complete line of Tenma Thermocouple Probes and Accessories
-
Product
Thermocouple Thermometers
-
Polarity: Automatic, positive implied, negative polarityindication.Low battery indication: The “ ” is displayed when thebattery voltage drops below the operating level.Measurement rate: 1 times/second.Operating environment: 0°C to 50°C at<70% R.H.Storage temperature: -20°C to 60°C, 0 to 80% R.H. withbattery removed from meter.Accuracy: Stated accuracy at 23°C±5°C, <75% R.H.Battery: 1.5Vx4pcs AAA size.Dimensions: 160mm(H) x 83mm(W) x 38mm(D).Weight: approx. 270g including batteries.
-
Product
Alarms
-
Devar alarms are designed to accurately monitor process trip-points from current, millivolt, DC volts and thermocouple signals. These alarm points can be easily set in percent of signal or directly in engineering units. The units will constantly monitor the set point against the actual signal and switch a 10 amp SPDT relay when the set point is exceeded. Alarms are available in wall mount, panel mount, track or DIN rail mount, AC/DC line voltage powered or loop powered versions.
-
Product
MAX31855 J-Type Thermocouple Arduino Shield
SEN-30004-J47
-
Four channel MAX31855 digital thermocouple Arduino Shield. Two versions of this shield are avaliable for each thermocouple type: either 'Ch 0-3' (CS pins use Uno/Mega IO pins 7-10) or 'Ch 4-7' (CS pins use Uno/Mega IO pins 3-6), with the only difference being which set of zero-ohm resistors are populated on the board. This allows use of other SPI devices that may be 'hard coded' to specific digital pins on the Arduino, or simply stacking one of each type together to get a total of eight thermocouple channels on one Arduino. The MAX31855J supports a measured temperature range of -210C-1200C with known thermal characteristics and output resolution of 0.25C. Included thermocouple connectors are type-specific to provide proper material continuity as close to the IC as possible. The SEN-30004 is interfaced via 3 or 4-wire SPI and a high-speed level shifter is included to allow the board to plug directly into an Arduino Uno or Mega
-
Product
MAX31855 K-Type Thermocouple Arduino Shield
SEN-30004-K47
-
Four channel MAX31855 digital thermocouple Arduino Shield. Two versions of this shield are avaliable for each thermocouple type: either 'Ch 0-3' (CS pins use Uno/Mega IO pins 7-10) or 'Ch 4-7' (CS pins use Uno/Mega IO pins 3-6), with the only difference being which set of zero-ohm resistors are populated on the board. This allows use of other SPI devices that may be 'hard coded' to specific digital pins on the Arduino, or simply stacking one of each type together to get a total of eight thermocouple channels on one Arduino. The MAX31855K supports a measured temperature range of -270C-1372C with known thermal characteristics and output resolution of 0.25C. Included thermocouple connectors are type-specific to provide proper material continuity as close to the IC as possible. The SEN-30004 is interfaced via 3 or 4-wire SPI and a high-speed level shifter is included to allow the board to plug directly into an Arduino Uno or Mega
-
Product
NI-9210, 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module
784788-01
Temperature Input Module
4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module - The NI‑9210 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9210 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
Product
Measurement & Simulation
-
Highland Technology offers a wide array of tools for measurement, simulation, and control. Tachometers, thermocouples, RTDs, precision voltages, current loops, strain gauges, and more can be measured or simulated by Highland's products.
-
Product
Vaccine Temperature Monitoring System Data Logger
VTMS
-
MadgeTechs Vaccine Temperature Monitoring System (VTMS) is ideal for the continuous measurement and data logging of temperature sensitive vaccines or pharmaceuticals in refrigerators, freezers, and coolers. The system includes a NIST traceable RFTCTemp2000A data logger with thermocouple, Glycol bottle and a power supply.
-
Product
Full-Featured Thermocouple and Voltage Measurement Instruments
EX10XX Series
-
A wide range of measurement types, including pressure, strain, temperature, position and voltage, can be performed using this instrument when combined with the EX10SC signal conditioning expansion chassis. Each input incorporates an independent signal conditioning path with software selectable filters for maximum flexibility.
-
Product
16 Channel Isolated Thermocouple And Voltage Measurement Instrument
EX1401
-
The EX1401 delivers accuracies of ±0.20°C, 1000 V channel-channel isolation, built-in self-test capabilities, and independent 24-bit ADC’s per channel. Its ability to acquire data at 20K samples/second/channel allows its usage in high-speed temperature transient applications. Deploy it in a variety of applications, including automotive and battery testing, jet engine testing, highly accelerated life test/highly accelerated stress screening (HALT/HASS), and health monitoring. It can be used in any test environment that requires accurate temperature measurement and repeatability. Parallel data storage and standalone autonomous operating modes further expand the utility of this versatile instrument.