Thermocouples
Thermocouples are junctions of two dissimilar metals that produce a very small voltage proportional to the temperature of the junction.
-
Product
MAX31855 K-Type Thermocouple Sensor Breakout
SEN-30003-K
-
Breakout board for the MAX31855K digital thermocouple interface ICs by Maxim. Measured temperature range is -270C-1372C with known thermal characteristics and output resolution of 0.25C. This sensor supports a larger operating range (specifically in the negative range) than its predecessors, the MAX6674 and MAX6675, though it is not pin-pin compatible. This board is interfaced with a 0.1" 2x5 pin header (8-pins used), has four vertical mini thermocouple connectors and four mounting holes for standoffs and 4-40 screws.
-
Product
External Double Way Temperature Datalogger
VA602-TK-TJ
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Two tunnel data logger with voltage current temperature (thermocouple) K.J.PT type, with USB, up to 16000 data record point.
-
Product
Exhaust Gas Thermocouple
LM2500 T5.4
-
AMETEK is the original OEM for the T5.4 EGT. We supply the L44830P01, L44830P02 and L44830P03 probes for use on the LM2500, LM2500+ and LM5000 gas turbines. In addition to the EGT, we also provide rigid harness, T3 probes, cables and flexible harness for these engines. Ensure you get the highest quality by selecting OEM qualified parts to keep your engine running reliably.
-
Product
Calibration And Verification Instruments
-
The system of automatic calibration and verification consists of a computer of the operator's workplace and a control controller with a calibrator connected to it and a verified device. The device under test can have 4 to 16 working channels with a complicated circuit for connecting different types of signals: voltage, current, thermocouples, thermoresistance. The system allows a change in the set of operating ranges during calibration and calibration. The software development system used the LabVIEW development environment with the Real-Time module.
-
Product
Temperature Data Logger with USB
VA602-XX-XX
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Two tunnel data logger with voltage current temperature (thermocouple) K.J.PT type, with USB, up to 16000 data record point.
-
Product
Thermocouple Probes
Type T
-
No matter the application, ThermoWorks has a probe for you: penetration probes, immersion probes, air probes, surface probes, wire probes, even specialized probes like griddle probes, burger probes, pipe clamp probes, and probes for medical and lab use. Choose from standard tip, reduced tip, corkscrew tip, alligator clip, or needle probes; different handle types; and straight, coiled, stainless overbraid or even armored cables. Sensor types include type T or type K thermocouples, RTD sensors and our Pro-Series® line of thermistor probes.
-
Product
K Thermocouple Immersion Probe
TP750
-
Immersion “K” Type thermocouple probe. Tolerance according to IEC 60584-2 standard.
-
Product
Calibration Cable, 78-pin D-type, Thermocouple Simulator Modules
40-975-078-1m
Calibration Cable
This cable assembly is specifically designed to connect to the 78-Pin D-Type port on the front panel of Pickering Interfaces Thermocouple Simulator Modules 41-760 and 41-761 enabling calibration via an external DMM.
-
Product
MAX31855 J-Type Thermocouple Arduino Shield
SEN-30004-J03
-
Four channel MAX31855 digital thermocouple Arduino Shield. Two versions of this shield are avaliable for each thermocouple type: either 'Ch 0-3' (CS pins use Uno/Mega IO pins 7-10) or 'Ch 4-7' (CS pins use Uno/Mega IO pins 3-6), with the only difference being which set of zero-ohm resistors are populated on the board. This allows use of other SPI devices that may be 'hard coded' to specific digital pins on the Arduino, or simply stacking one of each type together to get a total of eight thermocouple channels on one Arduino. The MAX31855J supports a measured temperature range of -210C-1200C with known thermal characteristics and output resolution of 0.25C. Included thermocouple connectors are type-specific to provide proper material continuity as close to the IC as possible. The SEN-30004 is interfaced via 3 or 4-wire SPI and a high-speed level shifter is included to allow the board to plug directly into an Arduino Uno or Mega
-
Product
PXI Millivolt Thermocouple Simulator Module - 24 Channel
41-760-002
Simulator
This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types.
-
Product
DAQ Terminal Board
-
* Provides screw terminal connections for the Analog, Digital, Relay Driver and Thermocouple signals.* Mates with the 62-pin connector on the 2307 boards and the 2367 Minibox™.
-
Product
Thermometer, -20°C to +400°C, 7.9 ", 2.7 ", 1.2 "
72-6700
-
Infrared Thermometer*Three thermometers in one...Infrared, Pt100 ohm and Thermocouple*Accommodates 4 wire Pt-100 ohm probes and thermocouple types K, J, R, T, and E.*Selectable readings °C or °F*Data Hold function*Min./Max memory function*Laser guide for IR function*RS 232 output*Auto power off
-
Product
Temperature Measurement
K- TC8
-
The K-TC modules belong to the Influx K-series instrumentation range for CAN applications. The stackable K-TC is an ideal for those applications that require a large number of thermocouples for example vehicle durability, winter and summer testing.
-
Product
Data Acquisition System
DAQ
Data Acquisition Module
Data Acquisition (DAQ) systems are used to collect information for the purpose of documenting or analyzing an electrical or physical phenomenon, for example: temperature or pressure. They serve as a focal point in tying a wide variety of sensors together that indicate temperature, flow, level or pressure. The sensors convert a physical occurrence into a measurable electrical signal, which can be factored into command and control decisions. These high-speed DAQ systems feature different analog and digital input and output modules that can be used with a wide range of signal types including 4-20 mA current, thermocouples, and RTDs.
-
Product
K Thermocouple Immersion Probe
TP651_TP652
-
Immersion "K" Type thermocouple probe. °C max: 1200. Response time: 6 s.
-
Product
E-Type Thermocouple, 32°F to 900°F Temperature Sensor
745690-E002
Thermocouple Contact (ITA)
E-Type Thermocouple, 32°F to 900°F Temperature Sensor - The E-Type Thermocouple works with NI measurement devices and software to help you acquire temperature data within a measurement system. You can use LabVIEW or FlexLogger software and NI-DAQmx driver software to configure measurements and predefined scaling coefficients for the E-Type Thermocouple and acquire synchronized temperature data in units of degrees. The E-Type Thermocouple is available in various lengths and configurations including field-cuttable, ready-made sensors, and thermocouple wire extensions with a -20°F to 221°F temperature range.
-
Product
Multilogger
M1220
-
Universal datalogger with 4 hardware inputs. Two inputs for temperature-humidity probes and two inputs for thermocouples K, J, S, B, T, N. Multilogger can be installed permanently to Ethernet network or work as portable device. Included is traceable calibration certificate in accordance with EN ISO/IEC17025.
-
Product
Submersible, Thermocouple Based Temperature Data Logger
TCTemp1000
-
The TCTemp1000 is a rugged, submersible, battery powered, thermocouple based temperature data logger. This is a stand-alone, compact, portable, easy to use device that can measure and record data for up to 16,383 measurements per channel. The storage medium is non-volatile solid state memory, providing maximum data security even if the battery becomes discharged. Its real time clock ensures all data is time and date stamped.
-
Product
Temperature Calibration
-
In our temperature lab we have the capability calibrate a wide range of temperature products such as catering food probes from deli to restaurant, industrial systems for manufacturing and quality checks using thermocouples surface probes or insertion probes we also calibrate IR (Infrared) thermometers.
-
Product
K Thermocouple Immersion Probe
TP656/1
-
“K” Type thermocouple imemrsion probe. Tolerance according to IEC 60584-2 standard. °C max: 1000. Response time: 1 s.
-
Product
Thermocouple System
Model TCIC
-
Industrial Measurement Systems Ltd.
High Speed 8 Channel Thermocouple Interface CardPDF VersionModel TCIC Thermocouple Interface Card with USB or RS232 / 485Main FeaturesLow cost high speed thermocouple measurement 400 channels / second
-
Product
Compact USB Data Logger with Display
DW-USB-LCD
-
The Portable Series DW-USB-LCD USB Data Loggers displays and records temperature, humidity and dew point. The easy-to-read LCD display shows the current temperature or humidity along with the minimum and maximum reading since last reset. For applications that require more accuracy, a high accuracy temperature and humidity model is available. Thermocouple models can accept any J, K, or T type thermocouple with a mini-plug connector.
-
Product
NI-9210, 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module
785043-01
Temperature Input Module
4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module - The NI‑9210 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9210 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
Product
Cryogenic Temperature Sensors
Thermocouple wire
-
Thermocouple wire is used in a variety of cryogenic applications, but special techniques must be employed to approach temperature accuracies of 1% of temperature, even without consideration for the effects of high magnetic fields or high radiation fluxes. The problems are further complicated by exposure to variable gradient conditions at cryogenic temperatures.
-
Product
PXIe-4303 , 24-Bit, 32-Channel, 51.2 kS/s, ±10 V PXI Analog Input Module
783866-01
Analog Input Module
24-Bit, 32-Channel, 51.2 kS/s, ±10 V PXI Analog Input Module—The PXIe‑4303 is a filtered input module for voltage, thermocouple, and current measurements. The module offers you the ability to select a digital filter per channel to provide extra filtering performance. You also can operate up to four different sample rates and triggering configurations concurrently to ensure you measure every sensor as needed. The module has an A/D converter per channel to enable a simultaneous sample rate at the maximum sample rate across the input range. The included NI‑DAQmx driver simplifies hardware configuration and measurement.
-
Product
Gauge Type T Thermocouple Wire
W-TW-40P
-
Most thermocouple wire used in the manufacture of sensors is "Special Limits" wire which, to meet NIST standards, must be accurate to 0.5°C in the range 0-50°C. This means that even with most sophisticated electronics, the best possible accuracy for the system is 0.5°C.
-
Product
Temperature/Process Controller
4B
-
The Series 4B 1/4 DIN Temperature/Process Controller is designed to accept thermocouple, RTD, current or voltage input and provide dual outputs for control. Available outputs include relay/relay, voltage pulse/relay, current/relay, or linear voltage/relay
-
Product
Flexible Multisensor Probes
IT Series
-
Physitemp multisensors are made with our specially manufactured thermocouple wire. We test and grade this wire to standards better than the accepted ''Special Limits of Error'' and guarantee 0.1°C accuracy in the range of 0-50°C . All multisensor probes conform to NIST standards. These multisensor probes are custom-made and should be ordered to your requirements on number of sensors and spacing between sensors.
-
Product
Compensation Block for Thermocouple Simulator Modules
40-965-912
Isothermal Termination Block
The Compensation Block is a accessory specifically designed for the 41-760 and 41-761 Millivolt Thermocouple Simulator modules. This block will give the user the temperature of the front panel junction of the module to cabling. This data can then be combined with other factors, temperature on the other end of the cable for example, to compensate the thermocouple hence increase the accuracy.





























