Reactive Load Banks
Provide both lagging and leading power factor loads.
See Also: Load Banks, AC Load Banks, DC Load Banks, Inductive Load Banks, Resistive Load Banks
-
Product
Signal Module, ITA, QuadraPaddle, 480 Position, Fully Loaded With Round Posts (610 138 115)
510151108
ITA Module
QuadraPaddle modules are molded on .100” (2.54 mm) centers to meet the need for high-density I/O in a compact assembly. Allowing flexible configuration options with standard commercial connectors. Available in 192 and 480 contact positions, QuadraPaddle modules accept standard .100” (2.54mm) pitch headers, breadboards, and connectors for direct PCB, ribbon cable, and other connections as well as discrete wiring.
-
Product
Wireless Load Cells
LoadSense
-
We are manufacturers of LoadSense Wireless Load Cells and transducers ranging from 1 to 50 tonnes. If you are not entirely sure about your requirements, please contact us for assistance.
-
Product
Programmable DC Electronic Loads
SDL1000X/X-E Series
-
SDL1000X/SDL1000X-E series Programmable DC Electronic Load has a 3.5 inch TFT-LCD display, a user-friendly interface and superb performance specifications. The SDL1020X/SDL1020X-E models feature an input range of 150 V/30 A 200 W while the SDL1030X/SDL1030X-E have an input range of 150 V/30 A 300 W. The SDL1000X series leads with measurement resolution of 0.1 mV/0.1 mA and the base SDL1000X-E series resolution is 1 mV/1 mA and adjustable current rise times from 0.001 A/μs~2.5 A/μs. For remote communication and control, the SDL series includes RS232/USB/LAN interface types. The SDL1000X series delivers stability over a wide range of applications and can meet all kinds of testing requirements. including: Power, battery/handheld device design, industry, LED lighting, automotive electronics, and aerospace.
-
Product
Compact Low Profile Load Cell
1000 Series
-
Compact Low Profile load cells are fully stainless steel, hermetically sealed load cells with a multi-beam internal structure, and fully integrated electronics to provide high level analog or digital outputs. This type of load cell is easy to use for measuring tension or compression loads from 200N (50lb) to 5kN (1000 lb), and is capable of rejecting side forces that would otherwise affect accuracy. This type also offers the user the ability to set the gain and offset (span and zero) electronically, to provide maximum flexibility for the user application.
-
Product
DC Electronic Load, Single-Input: 150V, 40A, 250W
EL33133A
-
The Keysight EL33133A bench DC electronic load provides a single input and a built-in data logger. Provide static or dynamic load test up to 40 A and 150 V. Display results in a meter view or over time using the built-in data logger.
-
Product
AC Load Banks
XL1000-XL1250 Series
-
Mosebach Manufacturing Company
The XL1000-XL1250 Series load banks offer you a continuous load at various voltages in a compact, lightweight enclosure.
-
Product
Signal, Module, Receiver, QuadraPaddle, 480 Position, Fully Loaded With Twin Female Contacts And Round Posts (610138200 And 610138117)
510150135
Receiver Module
QuadraPaddle modules are molded on .1” (2.54 mm) centers to meet the need for high-density I/O in a compact assembly. Allowing flexible configuration options with standard commercial connectors, QuadraPaddle modules are designed to fit any VPC pin and socket-based mass interconnect system. Available in 192 and 480 contact positions, QuadraPaddle modules accept standard .1” (2.54mm) pitch headers, breadboards, and connectors for direct PCB, ribbon cable, and other connections as well as discrete wiring.
-
Product
High Power DC Electronic Loads
63200A
-
Chroma Systems Solutions, Inc.
Chroma High Power DC Electronic Loads provide wider operating voltage and current ranges up to 240kW, sine wave loading, dynamic frequency sweep to 50kHz, digitizing, MPPT, an impressive front panel that tilts, and the highest accuracy available (voltage 0.015% + 0.015% F.S. and current 0.04% + 0.04% F.S.) – all with an incredibly high power density (6kW @4U).
-
Product
150~300W DC Electronic Loads
JT631 Series
-
Nanjing Jartul Electronic Co., Ltd
JT631 series electronic load is functioned with 500KHz high-speed synchronous sampling, DSP technology, powerful dynamic test and multi-aspect intelligence analysis. All these are fully integrated into auotmatic test function, which makes JT631 series load very suitable for testing power supply when produced in large quantity. Besides, JT631 series load also possesses the features of current rising slew rate programmable, high-speed dynamic loading and programmable list function, which makes JT631 series load satisfing most of R&D requirements. Moreover, JT631 series load’s special parallel operation method can satisfy the synchronous loading requirements of multi-channels output power supply and satisfy single-channel output power supply requirement for big power.
-
Product
DC Electronic Load
EE30141A
-
The EE30141A DC Electronic Load / Works @ 0.0 Volts Input & real time I/O control. attach the electronic load block to a heat- sink and your up and running. used them with D to A's, A to D's, Pots, PLC's to control the current. These Electronic Loads can be used for both Discharge & Charging Batteries & Devices
-
Product
Load tester for JA and C Type Durometers
-
It is necessary to check the shape and height of the indentor, the indicating mechanism, and other parts of the hardness tester are set correctly before doing a load test.
-
Product
Electric Servomotor Axis Direct Load Torsion Tester
-
This equipment is a testing machine for the purpose of conducting torque and vibration fatigue / durability test of suspension bush.
-
Product
Industrial Weighing - Wireless Load Cells
-
A wireless industrial weighing scale system can be advantageous, for instance when running conduit for cable is impossible, or if the cable could be damaged easily. In some cases the wireless interface is more economical than long runs of cable. These systems can be battery operated or hard wired to a power source if available. View our wireless load cell options below.
-
Product
Load Monitoring Units (LMUs)
-
Magtrol's Load Monitoring Units are used for measuring load, force and weight from signals generated by strain gauge transducers. Specifically designed for use with Magtrol's Load Measuring Pins and Load-Force-Weight Sensors, the LMU Series provides excitation voltage while conditioning the bridge output signal. Each unit contains DIP-switches and jumpers for greater flexibility and complete adaptability
-
Product
PXI MUX 8 Banks of 8 Channel Screened 1 Pole
40-610-021-S-8/8/1
Multiplexer Module
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector.Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
Load Length Meter
-
Design for finding out the total voltage of neon tubes in a circuit, help to Choose correct rating of neon transformer;- Easy to use just like a neon transformer;- With color LED indicators, clearly shows the test result;- With build-in over voltage protection circuit.
-
Product
Load Cell Amplifier Signal Conditioner with Removeable Terminals
MODEL LCA-RTC
-
The LCA-RTC Module provide low-cost, dedicated signal conditioning for a single bridge type load cell or torque sensor. Model LCA-RTC comes with removable screw-clamp terminal connectors, which accept wires without soldering.On- board jumper selections include sensitivities from 0.5 mV/V to 10 mV/V, bandwidths from 100 Hz to 30 kHz, and amplified outputs of 0 to ±5V, 0 to ±10V, 0-16 mA, 0-20 mA or 4-20 mA. Zero and span adjustments are via precision 25-turn low-tempco metal film potentiometers.The units can be operated next to the sensor with 4-wire hookup or at distances up to 1 km (3300 feet) with 6-wire hookup. An onboard 87.325 kΩ resistor allows easy shunt calibration at the push of a button. Provision is also made for a user-furnished calibration resistor. Power requirements are 11.8 to 26V DC with load currents from 10 to 60 mA, the latter applying when the unit provides 10V DC excitation to a 350 ohm load cell and delivers a 20 mA analog output.
-
Product
High Precision Canister Load Cell
Model 2000 Series
-
The Model 2000 Series High Precision Canister Load Cell was designed to accurately and precisely measure force, which many other quantities such as torque, thrust, and pressure are based, for aerospace applications. The Model 2000 Series, available with load measurement capacities up to 750K lbf, offers high performance and linearity and very low hysteresis. ±0.02% FS Hysteresis
-
Product
PXI Solid State MUX, 20 bank, 8 channel
40-680-001
Multiplexer Module
Based on FET switches, the multiplexers have no wear out mechanism and include fault protection that ensures the multiplexer automatically disconnects when PXI power is not applied. Available configurations for the 40-680 range vary from a single 160 to 1 MUX to a 20-bank, 8 to 1 MUX in a single PXI module.
-
Product
AC & DC Action Load Test
-
Shanghai Guantu Technology Co., Ltd.
1. AC action load power supplyVoltage range: 0~1000V;Current range: 5A ~ 100A.2. DC action load power supplyVoltage range: 0~1500V;Current range: 5A ~ 100A.
-
Product
Artificial Resistive Load
326
-
An industry staple for over 50 years, the TESCO Artificial Resistive Load (Catalog No. 326) has been redesigned to meet 21st century standards, making it the most cost effective, portable and light weight artificial load box on the market today.
-
Product
Mini Low Profile Load Cell Universal/ Tension or Compression
MLP SERIES
-
The model MLP Series load cells were designed with economy as first priority. They are a scaled down version of our successful LPO Series Load Cells. MLP-10 through MLP-300 are anodized aluminum and the MLP-500 through MLP-1K are made from 17-4ph heat treated stainless steel. The unique low profile design of the MLP Series provides excellent stability for in line applications for tension and/or compression, while saving space at the same time.
-
Product
AC Electronic Load
-
AC&DC Electronic Loads are design for testing uninterruptible power supplies(UPS), Off-Grid Inverters, AC sources and other power devices such as switches, circuit breakers, fuses and connectors.
-
Product
6 Way GPS / GNSS Signal Splitter Passive, 1-2 GHz, SMA, DC Block+200Ω Load 6 Ports
GPS612
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo splitterLow Insertion Loss (0.5 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.15 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy SMA Female (Jack) 50 Ohm
-
Product
Saluki SEL7 Series Programmable DC Electronic Load (up to 6kW)
-
The new SEL7 series programmable DC electronic load is a new generation product designed by Saluki Technology. Incorporating high-performance chips, the SEL7 series delivers high speed and high accuracy with a resolution of 0.1mV and 0.01mA (basic accuracy is 0.03% and basic current rise speed is 2.5 A/μs).SEL7 series have wide application from production lines for cell phone chargers, cell phone batteries, electronic vehicle batteries, switching power supplies, linear power supplies, and LED drivers, to research institute, automotive electronic, aeronautic and astronautic, maritime, solar cell and fuel cell etc. test and measurement applications.
-
Product
High Load Shear Strength Tester
HLST1000
-
This tester measures the shear force required to analyze the bonding strength of various bonding materials. It is possible to measure shear force up to 5000N for the purpose of bonding strength evaluation over a large area. An optional heating unit enables evaluation while the sample is heated.
-
Product
Network Simulation and Load Testing
-
EXFO offers a complete range of high-performance test solutions, covering the entire converged network from RAN to IMS. By mimicking real-world customer behavior in lab environments, our solutions allow mobile operators and equipment manufacturers to verify their wireless networks before deployment.
-
Product
Battery Load Banks
-
Kongter Test & Measurement Co., Limited
Kongter offers many different models of battery load units for real capacity test in various industries. With our customized solution, users of different applications will find their exact models as per their needs. With its optional DAC (Data Acquisition Case), you could easily monitor voltage of each cell on PC during battery discharge test.
-
Product
DC Electronic Load Control Software
EES-100-xx
-
EES-100 Software controls all electronic load types. ( Single & Dual channel) data logging, constant current, constant voltage, constant power, constant resistance, up-down timing, V/I Curves, Graphing, Response Testing
-
Product
Preselectors and Switch Filter Banks
-
Our preselectors and switch filter banks offer low noise figure, high dynamic range, state-of-the-art filter rejection with high channel-to-channel isolation front ends, realized in compact building blocks, designed in custom form factors. Applicable markets include: EW, missiles, radar, communications and space.