Reactive Load Banks
Provide both lagging and leading power factor loads.
See Also: Load Banks, AC Load Banks, DC Load Banks, Inductive Load Banks, Resistive Load Banks
-
Product
Stand Alone/ Bench Top Load Cell Amplifier/ Conditioner Module
MODEL TMO-2
-
The TMO-2 Transducer Modules is a complete differential amplifier/signal conditioners with self contained power. The units provide excitation, balance and span adjustment via precision 10 turn pots, and shunt calibration necessary to couple a user supplied bridge type transducer to an indicating instrument. Full scale output is specified at plus or minus 10 VDC. The TMO-2 provides a floating shunt calibration circuit which applies calibration at the transducer, thereby eliminating errors due to line losses. The excitation supply incorporates a Wagner Ground to greatly improve Common Mode Rejection. The factory set bandwidth of the module is narrow to improve stability for applications such as weighing scales. The removal of a single capacitor will increase the frequency response DC to 60K Hz for dynamic data applications.
-
Product
PXI MUX 2 Banks of 32 Channel 2 Pole
40-610-022-2/32/2
-
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
ResMap or DualMap Auto Load Floor Standing
-
Creative Design Engineering, Inc.
*Type: Floor Standing*Wafer load: FOUP LoadPort*Wafer size: 300mm, 8" and 300mmopen cassette with adapter*Mini Environment: yes*Probe Changer: 1,2 or 4 probes*Aligner: yes*Range: 1m/ to 10M/*Accuracy:0.5%*Repeatability: 0.02% *Static Repeatability: 0.1% dynamic
-
Product
DC Loads
-
Becker Nachrichtentechnik GmbH
Becker Nachrichtentechnik offers wideband multichannel DC decouplers for antenna diagnostic applications. Due its high bandwidth the device is suitable for all broadcast, cellular and Wi-Fi standards.
-
Product
Pancake Load Cell
-
Futek Advanced Sensor Technology, Inc.
The Pancake Load Cell category offers 20 models built for Endurance, Off-Center Loading, or Inline applications. These models are available in a wide capacity
-
Product
Load Testing for Evolved Packet Core (ePC/VePC)
Flare
-
Linkbit Flare is designed for load testing of Evolved Packet Core (ePC) networks, and the upcoming VePC deployments. It is based on the technology initially develped for Linkbit functional testers, and as a result is extremely flexible.
-
Product
Battery Load Tester
BT-100
-
Schumacher Electric Corporation
FOR EVERYDAY DIY USEEasy to operateTest load, battery condition, starter motor draw and complete charging system diagnosis.Works on 6 and 12 volt batteries50 amp load test for 6 volt batteries100 amp load test for 12 volt batteries Tests 6 and 12 volt batteries ─ up to 1000 CCATop-mounted rocker switch for easier operationSuper-grip, heavy-duty color-coded battery clampsEasy-to-read meter ─ accurate and shock resistantBaked enamel, steel case ─ ventilated to keep coolRubber insulated carrying handle ─ for comfort and safety
-
Product
Miniature S-Beam Load Cell
500 Series
-
The Miniature S-Beam Load Cell is a bi-directional Aluminium strain gage based transducer with high performance and builtin temperature compensation. This design provides better than ±0.1% (full scale) non-linearity and includes overload protection in both tension and compression directions. Options include IEEE1451.4 TEDS capability.
-
Product
600 Watt DC Electronic Load Mainframe
N3301A
-
The Keysight N3301A is a half-rack width mainframe with 2-slots that accepts combinations of N330x user-installable load modules (150 W to 600 W) for easy system configuration and future reconfiguration. The N3301A holds up to two N3302A, N3303A, N3304A, and N3307A load modules, or one N3305A and N3306A load modules, allowing up to 600 watts of total maximum power.
-
Product
PXI 10 Banks of 8 Channel 2 Pole MUX
40-615-022-10/8/2
-
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.
-
Product
Thermal Load Boards
-
Thermal Engineering Associates, Inc.
A Thermal Load Board (TLB) is used to simulate an application printed circuit assembly (PCA) either before all the heat-producing components are available for mounting on the application PCA or if the heat-producing components require complex electronic circuitry to create heat within the components. The TLB is typically designed to be as mechanically and thermally equivalent to the application PCA and usually offers a way to vary the power dissipation of the elements that simulate the heat-producing components.
-
Product
PXI MUX 1 Bank of 64 Channel 2 Pole
40-610-022-1/64/2
-
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
24V / 400 Amp Load
EL12-24M
-
For Battery Discharge testing and Power Supply testing. This particular Load has been designed to operate with Telecom 48V Rectifiers and Power Supplies with output Voltages in the range of 38V to 60V and is extremely cost effective.
-
Product
Battery Load Bank
-
Foresight Electronics Co., Ltd.
Utility is used for battery systems range from 21-30V, if higher current is needed, two or more FST-24V units can be linked together. Discharge to Battery string voltage as 24V, Cell voltage as 1.2V/2V/6V/12V adjustable stop points and multiple alarm designs to control the discharge process intelligently 7inch LCD touch screen for easy operation and showing various parameters real time Support RS232 real time monitoring by PC or SD Card download data after discharge
-
Product
QuadraPaddle Signal Insert, ITA, SIM, 4 Position (not Loaded- For Discrete Wiring Only)
510181101
-
QuadraPaddle Signal Insert, ITA, SIM, 4 Position (not loaded- for discrete wiring only)
-
Product
Through Hole/ Donut Load Cell Compression Only
THA SERIES
-
Our THA Series through hole donut load cells offer an outside diameter of 1.00 inches and up to two different through hole diameter options per capacity range. These load cells are manufactured from heat treated 17-4 ph stainless steel. The sensing element incorporates bonded foil strain gages of the highest quality and are sealed for protection against most industrial environments.
-
Product
PowerSync Programmable Loads (PSL-3424A, PSL3424L, PSL-3424M, PSL-3000)
-
Lower cost solutions for versatile 802.3at and 802.3bt Powered Device Emulation to support PSE system test and analysis
-
Product
PXI 2 Banks of 40 Channel 1 Pole MUX
40-615-021-2/40/1
-
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.
-
Product
PXI MUX 1 Bank, 64 Channel Screened 1 Pole
40-610-021-S-1/64/1
-
This series of high density multiplexer modules feature a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector. Inter-bank linking relays allow multiplexer size to be increased in multiples of in multiples of three by joining the common terminals of adjacent banks. Closing one linking switch produces a 6-channel multiplexer, closing all linking switches produces an 54-channel multiplexer
-
Product
Load Cells
-
Applied Weighing International Limited
Range of tension load cells are suitable for smaller Silo, vessel and tank weighing applications. The load cell can be supplied as a fully welded stainless steel or tool steel. Capacities from 1000kg to 5000kg Fitting options available including threaded bar, rod end bearing and eyebolts. ATEX option available.
-
Product
AC Loads
-
During AC electronic load tests, loads are simulated to confirm that a power device or system can operate properly, according to its capacity rating. This type of resistive load testing can often pinpoint power system issues in time for preventive maintenance to be performed. AC load tests can also evaluate the capacity of your essential batteries. Our loads are built to help you reduce downtime, power disruptions and risks to systems. They are valued in utility, transportation, data center, industrial manufacturing and communications environments. Our portable AC load products from Eagle Eye Power Solutions withstands harsh field testing conditions. The AC Load Banks from Eagle Eye are designed to test generator sets, UPS units, power inverters and other AC sources of power. Transcat also stocks devices that flexibly support both AC and DC load applications.
-
Product
High Speed Load Cell Test Interface
LCIC-4CH
-
Industrial Measurement Systems Ltd.
The latest stand-alone controller model: LCIC-4CH, was specially designed to fit portable wheel and axle scales for determining the weight of trucks or heavy vehicles either in static mode or in motion, with very high accuracy and very friendly to operate. The In-motion speeds up the weighing process and allows weighing a truck without the need to stop.In the last 16 years, our stand-alone High-Speed weighing-in-motion controller model: LCIC-WIM was sold all around the world and as for today, thousands are being in use when among our customers are some well known weighing manufacturers.Most of our customers around the world are scale manufacturers or integrators that were able to offer the market the most advanced WIM scale with very short time to market and minimum R&D expenses.
-
Product
Battery Extra Load Units
BXL Series
-
BXL is an extra load unit designed to be used with DV Power’s BLU series battery testers. However, this unit is a universal add-on device. Because of that, it is compatible, as an additional load, with any other discharge/capacity tester in the market.In case when discharge current exceeds the capacity of a single BLU device, BXL can increase the discharge capacity. There are no limitations on the number of extra load units that can be connected in parallel to the main battery tester.A system of BLU and BXL instruments enables performing the capacity test in an accurate, user-friendly way. Also, all instruments are in accordance with battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.These units can be used on any type of battery string, such as lead-acid, Li-Ion, Ni-Cd, etc. They test battery strings with voltages in the range of 5,25 – 500 V DC. On the other hand, current up to 250 A can be discharged through the BXL internal structure.The instrument simulates a constant resistance load during the discharge test. Several resistances can be set for different battery nominal voltage levels. This makes BXL extremely flexible in selecting its load capabilities.
-
Product
Load Cell Measurement Interface
LCIC-1106a
-
Industrial Measurement Systems Ltd.
Any application related to weighing or measuring forces is now available in your PC...Stand-alone microcomputer-based interface card requires no other interfacing accessories. Simply connect th
-
Product
Capacitive Bank Load
-
Supreme Instrument Laboratories
Capacitive Bank Load Three phase suitable for operation on 415/440 volts three phase AC 50Hz housed in well ventilated sheet steel cabinet with bakelite front panel, complete with indicating lamps, voltmeter to indicate the input voltage and Ammeters to indicate, the load. ON/OFF switch, discharge switch etc. available in continuously variable type.
-
Product
PXI 18 Bank, 3 Channel, 1 Pole Multiplexer
40-617-021
-
The 40-617 18-Bank, 3-Channel, 1-Pole Multiplexer Module forms part of the System 40 PXI Programmable Switching system. The Module consists of 18 electrically isolated banks of multiplexers controlled by a PXI/PCI interface. Each bank is a 1 to 3 multiplexer and operates with break-before-make action when a new channel is selected. Any Individual multiplexer bank can have a channel set by itself, alternatively, multiple banks can have channels selected simultaneously. Inter-bank linking relays allow multiplexer size to be increased in multiples of 3 by joining the common terminals of adjacent banks. Closing one linking switch produces a 6 channel multiplexer, closing all linking switches produces an 54 channel multiplexer.
-
Product
Electric Servo Motor Type High Speed, High Load, Large Displacement Vibration Tester
-
This tester is a high-speed, high-acceleration vibration tester equipped with an electric servomotor actuator.
-
Product
Signal, Module, Receiver, QuadraPaddle, 480 Position, Fully Loaded With Twin Female Contacts (610138200)
510150131
-
QuadraPaddle modules are molded on .100” (2.54 mm) centers to meet the need for high-density I/O in a compact assembly. Allowing flexible configuration options with standard commercial connectors, QuadraPaddle modules are designed to fit any VPC pin and socket-based mass interconnect system. Available in 192 and 480 contact positions, QuadraPaddle modules accept standard .100” (2.54mm) pitch headers, breadboards, and connectors for direct PCB, ribbon cable, and other connections as well as discrete wiring.
-
Product
Terminations & Loads
-
We have more than 40,000 rf & microwave coaxial terminations in stock we can ship today. We offer these Microwave & RF terminations: SMA Terminations, Type N terminations, 7/16 DIN terminations, 2.92mm terminations, 2.4mm terminations, TNC terminations, smp terminations, minismp terminations, 4.1/9.5 minidin terminations. 4.3/10 terminations, ssma terminations, ssmc terminations, and a few Reverse Polarity terminations. Power levels of 0.5-150 watts. RF / Microwave terminations are also known as dummy loads or 50 ohm dummy loads. Our 1.85mm terminations, are rated to 67ghz. We offer 1.0mm terminations good to 110Ghz.
-
Product
230V / 36 Amp Load
EL08-230M
-
For High Voltage UPS Battery Testing and Power Supply testing. This particular Load has been designed to operate with UPS Battery Systems and Telecom Rectifiers and Power Supplies with output Voltages in the range of 153V to 230V and is extremely cost effective.




























