Line Fault Indicators
See Also: Overhead Line
-
product
Indicators & Displays
30,000 displayed divisionsOIML R76 ApprovedStainless steel IP65 housingMains powered with 12V DC option25mm wide angle LCD display with back light2 programmable function keys and navigation keys provide easy operationLinearity correctionGravity AdjustmentLi-Ion long life rechargeable batteryAuto Power offPanel mount, desk stand, pole/wall bracket mounting includedRS-232C data port standard, 2nd RS-232C port optionTicket printing with Date, Time, Ticket no, Gross, Tare & Net Weight100 product memories for check weighing and countingSmart dynamic weighing algorithm for animal weighingCE approved
-
product
PXI 5A Fault Insertion Switch 20-Chan 1-Bus
40-198-001
The 40-198 is a 20 Channel Fault Insertion switch, primarily designed for the simulation of fault conditions in automotive/avionics applications involving the reliability testing of safety critical controllers.
-
product
Flow Indicators
Flow indicator with rotor features a self-cleaning mechanism to ensure full visibility of the rotor at all times. Typical sight flow indicators suffer from poor indicator visibility through normal use from build-up that impedes observation of the rotor through the viewing window. Typically, for a sight flow indicator to be cleaned, it must be removed from the pipeline, cleaned and then replaced at some specified time, such as during plant shutdown. Unfortunately, dirt build-up does not typically schedule itself to correspond with planned shutdowns. Enter the KOBOLD DAA Series flow indicator. Simply twist the sight glass and the integral wipers clean the flow indicator's viewing area to allow unobstructed observation of the rotor. The offending contaminants are then simply washed away by the media flow. This process may be repeated as often as desired with no fuss and no downtime. The DAA is available with brass or stainless steel fittings with " to 1" NPT female threads. The DAA is also available without a rotor for observation of fluid condition.
-
product
Fault Locating
Schweitzer Engineering Laboratories, Inc.
The built-in fault-locating methods in SEL devices allow you to quickly identify faults, dispatch crews for repairs, and restore service faster. Traveling-wave fault-locating technology calculates the locations of temporary and permanent faults by measuring the arrival times of the naturally occurring traveling waves caused by a transmission line fault. Accurately detecting these waves requires ultra-high-resolution monitoring, and locating is accurate to within one tower span (±300 m). Impedance-based fault-locating technology calculates fault locations by detecting changes in line impedance as a result of a fault. Impedance-based locating is reliable and accurate to about 2 percent of a line’s total length.
-
product
Voltage Indicator
Small installation devices for measuring both alternating and direct voltages.
-
product
Fault Locator
REZAP FAULTMASTER
REZAP FAULTMASTER is an auto-recloser that keeps customers on supply during intermittent faults.
-
product
Detection of PtG and PtP Faults in Line Networks
LineTroll 110Tμr
The indicator is powered by replaceable long-life lithium batteries which have a life expectancy of 10-15 years. It provides a 360 degree visibility for indication both for transient faults and permanent faults.
-
product
PXI/PXIe Fault Insertion Switch, 74-Chan 2A, N/C Through Relays, Fault Buses on M & U
42-190C-012
The 40-190C-012 (PXI) and 42-190C-012 (PXIe) are fault insertion switches with 74 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
40-203-001
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
Process Indicator
CS1-PR
CS1-PR economic type Process Indicator has been designed with high accuracy measurement, display and communication of DC signal 0~10V and 4(0)~20mA.They are also available 1 option of 1 Relay outputs, 1 Analogue output or 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission or communication for a wide range of industrial applications.
-
product
Dial Indicators
1. Always select the dial test indicator that best fits the application.2. Care should be taken while using a dial test indicator, try not to jolt the indicator, should you be unfortunate and drop a dial test indicator, get it re-calibrated/repaired before reusing it.3. Replace worn contact points only with those of a similar length from the centre of the ball stylus to the abutment shoulder.4. Always clean dial test indicators after use with a lint free paper or cloth and store the indicator in its box or in a dust free area.5. When using a dial test indicator, always position the dial test indicator in a horizontal plane to the surface media.6. Always use a rigid stand for mounting the dial test indicator.7. When measuring a rotating object, either between centres or in a vee block, ensure that the object is rotating in the correct direction. Never rotate the workpiece towards the contact point.8. When measuring a sliding object, only take readings when the object is moving directly towards the contact point, never away from the contact point or in a sideways manner.9. Avoid parallax errors by reading the dial directly from the front and square on to the dial.10. Never oil a dial test indicator as this attracts contamination, should the movement become erratic then the dial test indicator should be submitted to a reputable repair agent.11. Try not to expose dial test indicators to direct sunlight or in a high humidity environment.12. Never use a dial test indicator that has not been calibrated, if in doubt consult an appropriate authority.
-
product
Level Indicators
4B has a wide range of radio frequency (RF), rotary paddle and capacitance point level indicators for detecting high, intermediate, or low levels of liquids, powders and free flowing granular solids stored in tanks, bins, silos or other containers. Certain units can also be used as plug or choke detectors in chutes, conveyors and elevator legs.
-
product
Microprocessor Based Indicator
Strong Anodized NEMA4X-IP56 ALUMINUM 1/8 DIN CASE Compact Design Provides Excitation to Transducers or Sensors Accept DC mV/V, V, mA Signal Proportional Analog Output V or mA Easy to Program using 4 ButtonsFront Panel Shunt Calibration User Programmable High & Low Set Point Standard No-Output or Relay Output Optional 8-Step Output, RS232, or BCD Output Available
-
product
CAN/FlexRay/Differential Bus PCI Fault Insertion Switch - 4 Channel
50-200-004
This PCI Fault Insertion card is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This card supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses.
-
product
Navigational Control Indicator
58LD1-01
- 3Ø AC input- 1 DC output plus AC lighting output- 100 Watt output- Operation up to 70,000 feet
-
product
Visual Fault Locators
*Visual Fault Locator, we can understand its function in the letter. It could be regarded to be part of OTDR and the fiber fault locator is cheap.*Fiber visual fault locator is a kind of device which is able to locate the breakpoint, bending or cracking of the fiber glass. It can also locate the fault of OTDR dead zone and make fiber identification from one end to the other end. Designed with a FC,SC,ST universal adapter, this fiber testing red light is used without any other type of additional adapters, it can locates fault up to 10km in fiber cable, with compact in size, light in weight, red laser output.*Fiber visual fault locators include the pen type, the handheld type and portable visual fiber fault locator. Fiberinthebox also supply a new kind of Fiber laser tester/ optical fiber pen/ fiber laser pen, it can locates fault up to 30km in fiber cable.*Welcome to our store. Contact us at sales@fiberinthebox.com or Live Chat with us. Save your money & time right now! Buy from optical fiber supplies at Fiberinthebox.com with your confidence.
-
product
Sound Level Indicators
A sound level meter is a measuring instrument used to assess noise or sound levels by measuring sound pressure. Often referred to as a sound pressure level (SPL) meter, decibel (dB) meter, noise meter or noise dosimeter, a sound level meter uses a microphone to capture sound. The sound is then evaluated within the sound level meter and acoustic measurement values are shown on the display of the sound level meter. The most common unit of acoustic measurement for sound is the decibel (dB); however, some sound level meter devices also determine the equivalent continuous sound level (Leq) and other acoustic parameters. With a portable sound level meter, industrial hygiene and workplace safety professionals can measure sound levels in multiple locations to ensure environmental conditions fall within recommended exposure limits (RELs). Some sound level meter devices can be permanently installed for continuous monitoring of sound levels at a work or job site.An important attribute to consider when searching for a suitable sound level meter is its type or class. The type or class of a sound level meter defines the device's accuracy as per American National Standards Institute (ANSI) or International Electrotechnical Commission (IEC) guidelines. Typically, "type" is the grade according to the ANSI S1.4 standard, whereas "class" is the grade according to the IEC 61672 standard. There are two types or classes assigned to sound level meters: type 1 / class 1 or type 2 / class 2. For assessing noise in basic industrial, commercial, educational, recreational or residential applications, a type 2 / class 2 sound level meter usually will suffice. For precision-grade assessments often made in a laboratory, a type 1 / class 1 sound level meter primarily is used. PCE sound level meter products are lightweight, easy-to-use and manufactured in accordance with the highest industrial standards.
-
product
Pole Mounted Detector of PtG and PtP faults in 6-69V Line
LineTroll 111K
The unit mounts 3-5m below the conductors and monitors all three phases. The indicator is powered by replaceable long-life lithium batteries which have a lifeexpectancy of 10-15 years. It provides a 360 degree visibility for indication both for transient faults and permanent faults.
-
product
Subsystems And Line Cards
Eliminate your risks, lower your costs, and improve your system performance by partnering with a respected world leader in custom line card and subsystem solutions.
-
product
Phase Sequence Indicator
8PK-ST850
Two functions in one unit incluidng open phase and phase sequence. Large size alligator clips : able to clip on switch-board terminals easily. Identify 3 phase sequence and open phase check Ideal for installing conveyor lines, pump systems and interconnected drivers. No exposed metal parts. Safety features are incorporated throughout, including the pushbutton switch designed to minimize damage due to negligence. Safety approval: CE marks, IEN 1010 CAT. II.
-
product
Underground Fault Location
Schweitzer Engineering Laboratories, Inc.
Underground faulted circuit indicators identify the faulted cable section without a time-consuming re-fuse and sectionalize process. Applications include subsurface or pad-mounted transformers, switchgear, sectionalizing cabinets, junction boxes, and splices.
-
product
Line Post Sensors
These products are designed for distribution circuits only at their rated capacities. They cannot be field modified for capacities other than what was shipped with the units.
-
product
Line Scan Camera
Linea ML
The Linea ML brings leading edge CMOS technology that is faster than ever, with affordable multiline architecture that enables the newest, most powerful inspection techniques including HDR, color and multispectral analysis, and multi-field imaging (single-pass bright/darkfield). With a native fiber optic interface for easy, low-cost long cabling, the Linea ML opens new horizons in inspection.
-
product
Visual Fault Locators
MVFL Series
Shanghai Tarluz Telecom Tech Co., LTD
MVFL series Visual Fault Locators is meet the Class IIIA product, which is the easiest way to identify fibers from end to end and locate polished connector endfaces. Its red laser shines through most yellow-jacketed fibers to help you pinpoint breaks, bends, faulty connectors, splices and other causes of signal loss. The 1mW output power enable the MVFL has a reach of up to 5 km. MVFL seires VFL locates faults visually by creating a bright red glow at the exact location of the fault on single mode (SM) or multimode (MM) fibers. Due to its small size, lightweight and simple but proven design, the MVFL can accompany you anywhere In your pocket or belt pouch in harsh environment
-
product
Digital Fault Recording
SHERLOG
Fault recorder systems with a power quality analyser for comprehensively monitoring and assessing low, medium and high voltage networks in power plants and transformer substations. The measuring devices of the SHERLOG range make very high-resolution recordings of all the disturbances which occur in power supply systems. The behaviour of protection and switchgear devices during these system disturbances is recorded at the same time.
-
product
Ground Fault Location
Kongter Test & Measurement Co., Limited
Kongter offers a whole line of ground fault locator from basic to advanced model to fast detect, trace and pinpoint virtual grounding faults in DC systems when systems are LIVE (working online). Without injecting any signal to the DC system, they are safe to your existing system. With Kongter’s unique technique for signal tracing, these ground fault locators are much faster and more effective to find the earth fault in the field than its peers.
-
product
Indicating Differential Pressure Transmitter
605
The Series 605 Magnehelic Indicating Transmitter provides for both visual monitoring and electronic control of very low differential pressure.
-
product
Cable Fault Locator
HT-TCD / 405
Wuhan Huatian Electric Power Automation Co., Ltd.
Power cable fault test, cable path, cable depth, railway and airport signal control cable and street lamp cable fault test.





























