Optical Modulation
See Also: Modulation, Modulation Analysis, Modulation Analyzers, Modulation Meters, MER
-
Product
LXI Microwave Multiplexer, 50Ω 4-Channel 10-Bank 26.5GHz SMA
60-802-310
Multiplexer Module
The 60-802-310 is a 4-channel, 10-bank RF multiplexer suitable for switching 50Ω signals up to 26.5GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
PXI 5A Mux 2-Bank 24-Ch Isolated COM + Ind Isolation
40-651-112
Multiplexer Module
This range of high density power multiplexer modules is suitable for switching inductive/capacitive loads up to 5A at 250VAC. It is available in the following 1-pole multiplexer formats: 1-bank 48-channel. 2-bank 24-channel. 4-bank 11-channel. 8-bank 5-channel.Connections are made via a front panel 50-way male D-type connector. Power multiplexer modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids.
-
Product
PXI/PXIe Wide Current Range Multiplexer Module, Dual 3-Channel, 4-Pole
42-514-101
Multiplexer Module
The 40-514-101 (PXI) and 42-514-101 (PXIe) are low density multiplexers in dual 3-channel, 4-pole configuration. They are capable of switching a wide range of current, from 10 μA to 2.5 A at 220 VDC/250 VAC. The current capability of the module permits the use of a single module type for both low and medium current test applications.
-
Product
PXI/PXIe RF Multiplexer, Single 8-Channel, 3GHz, 50Ω, SMB
40-874A-001
Multiplexer Module
The 40-874A-001 (PXI) and 42-874A-001 (PXIe) are 50 Ohm 8 to 1 RF multiplexers with 1 bank in a single slot. They have low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss.
-
Product
PXI 2A Multiplexer, 4-Bank, 32-Channel, 1-Pole
40-614B-006
Multiplexer Module
This 4-bank, 32-channel, 1-pole version is part of the 40-614B High Density 2A multiplexer module range that is available in 20 configurations (see Also in this Range link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
Signal, Module, ID, CASS, QuadraPaddle, 800 Position
510114131
ITA Module
Signal, Module, ID, CASS, QuadraPaddle, 800 Position.Mating module is 510113138.
-
Product
PXI Module Adapter, Pull Thru Adapter, Receiver, 1 Position
510109462
Adapter Module
PXI Module Adapter, Pull Thru Adapter, Receiver, 1 Position.
-
Product
LXI Microwave Multiplexer, SP4T, 8-Bank, 26.5GHz, 50Ω, SMA
60-803-308
Multiplexer Module
Our 60-803-308 is a 8 bank terminated SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 26.5GHz. The 60-803 range is capable of supporting up to 14 banks of terminated 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
PXI/PXIe MEMS Optical MUX, 4-Channel, Multi-Mode, 62.5/125 Fiber
40-850A-214-M62.5-HI
Multiplexer Module
The 40/42-850A-214-M62.5-HI is a PXI/PXIe 4-channel multiplexer with SC/PC connectors, includes hardware interlock and is part of Pickering's range of PXI Fiber Optic MEMS Switching modules. They are available in many high density formats with a choice of different connector styles to suit most applications: FC/APC (for optimal performance), FC/PC and SC/PC for general applications and LC and MU for high density applications.
-
Product
Switch Modules - 16 Single Pole, Form C, Discrete Relays which are Wired & Controlled Individually
JX16/KC
Switch Module
This module has 16 single pole, Form C, discrete relays which are wired and controlled individually. The relays can be externally wired to make any configuration needed. Use as individual A-B relays or use them to drive external relays, solinoids, or any external device. It is available with Type S or M reed relays.
-
Product
PXI/PXIe Microwave Multiplexer, Single SP4T, 50GHz, 50Ω, SMA-2.4
40-785C-451-E
Multiplexer Module
The 40-785C-451-E (PXI) and 42-785C-451-E (PXIe) are single SP4T 50GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-785C range of multiplexers are available as single or dual, SP6T or SP4T panel mounted multiplexers with relays mounted on the front panel. The single slot version can support up to three supplied remotely mounted multiplexers.
-
Product
Keysight Quad 1x4 75 Ohm 1.5 GHz Multiplexer Module for 34980A
34942A
Multiplexer Module
The Keysight 34942A RF multiplexer module for the 34980A Multifunction Switch/Measure Unit offers bi-directional switching broadband signals. High channel isolation ensures quality dynamic range measurements with your oscilloscope, spectrum analyzer, or other instrumentation.
-
Product
PXI/PXIe RF Multiplexer, Single 4-Channel, 3GHz, 75Ω, SMB
42-832A-001
Multiplexer Module
The 40-832A-001 (PXI) and 42-832A-001 are 75 Ohm 4 to 1 RF multiplexers with 1 bank in a single slot. They have been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. Each MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz with each path having a nominally equal insertion loss. The design of the 40/42-832A minimizes the injection of noise and unwanted signals into the signal path by careful attention to the mechanical and electrical design.
-
Product
LXI Microwave Multiplexer, SP6T, 11-Bank, 26.5GHz, 50Ω, SMA
60-800-311
Multiplexer Module
Our 60-800-311 is a 11 bank terminated SP6T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 26.5GHz. The 60-800 range is capable of supporting up to 14 banks of 6 channel terminated multiplexers and is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
DC Power Module, 8 V, 6.25 A, 50 W
N6732B
Power Module
The Keysight N6732B 50 W basic DC power module provides programmable voltage and current, as well as measurement and protection features at a very economical price. Use this module to power your DUT or ATE system resources, such as fixture control.
-
Product
PXI/PXIe High Voltage Multiplexer, Quad 5-Channel, 1-Pole
42-321-101-HI
Multiplexer Module
The 40-321-101-HI (PXI) and 42-321-101-HI (PXIe) are quad 5-channel 1-pole high voltage multiplexers capable of hot or cold switching up to 1000 V peak. They are also available in a range of bank sizes with 1 or 2 poles and channel counts between 4 and 48. High quality reed relays are used throughout.
-
Product
PXI Breadboard Module, 2-Slot, 20-Pin GMCT
40-220A-802
Signal Module
The 40-220A series of breadboard modules allow the user to construct their own circuit in situations where a suitable PXI module is not available. For example when it is required to integrate a non-switching function into a PXI chassis. Typical applications include: Creating custom circuitry that can be housed in on a 3U board, or to build special one-off switching modules.
-
Product
PXI 3A Power MUX BRIC, 6-Channel, 16-Pole
40-571-202
Multiplexer Module
The 40-571 is a Power Multiplexer designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is possible for most configurations, see switching specifications for restrictions). It is ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. It is available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts.
-
Product
PXI/PXIe Microwave Multiplexer, Dual SP8T, 40 GHz, 50 Ω, SMA, Terminated, Remote Mount
40-788-052-TE
Multiplexer Module
The 40-788-052-TE (PXI) and 42-788-052-TE (PXIe) are single SP8T 40 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays.
-
Product
PXI/PXIe High Density 2A Multiplexer, 8-Bank, 8-Channel, 2-Pole
42-614D-004
Multiplexer Module
The 40-614D-004 (PXI) and 42-614D-004 (PXIe) 8-bank, 8-channel, 2-pole multiplexers are part of the High Density 2A multiplexer module range available in 23 configurations (see 'Also in this Range' link above). All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC.
-
Product
LXI Microwave Multiplexer, 50Ω 4-Channel 1-Bank 40GHz SMA-2.9
60-802-401
Multiplexer Module
The 60-802-401 is a 4-channel, 1-bank RF multiplexer suitable for switching 50Ω signals up to 40GHz. It is part of Pickering Interfaces’ range of LXI Microwave Multiplexers which are available with bandwidths between 6GHz and 40GHz and support for 4, 8 12 or 16 banks of 4 or 6-channel multiplexers. It is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA or SMA-2.9 connectors.
-
Product
LXI Microwave Multiplexer, SP4T, 15-Bank, 67GHz, 50Ω, SMA-1.85
60-803-815
Multiplexer Module
Our 60-803-815 is a 15 bank SP4T multiplexer and is part of a range of LXI based microwave multiplexers suitable for switching 50 ohm signals up to 67GHz. The 60-803 range is capable of supporting up to 16 banks of 4 channel multiplexers it is ideal for constructing complex microwave switching systems for many applications. Connection is by high performance front panel mounted SMA, SMA-2.9, SMA-2.4 or SMA-1.85 connectors.
-
Product
NI-9475, 60 V, 8-Channel (Sourcing Output), 1 µs C Series Digital Module
780132-02
Digital Module
60 V, 8-Channel (Sourcing Output), 1 µs C Series Digital Module - The NI‑9475 works with a variety of industrial devices such as solenoids, motors, actuators, relays, and lamps. Each channel sources up to 1 A at levels up to 60 VDC and features isolation from … channel‑to‑earth ground.
-
Product
PXI/PXIe Microwave Multiplexer, Triple SP6T, 40 GHz, 50 Ω, SMA-2.9, Terminated, Remote Mount, Failsafe
42-785C-543-TE
Multiplexer Module
The 40-785C-543-TE (PXI) and 42-785C-543-TE (PXIe) are triple failsafe SP6T 40 GHz microwave multiplexers with automatic termination of unused signals and remotely mounted relays. The 40/42-785C range of multiplexers are available in single or dual, SP6T or SP4T configurations with relays mounted on the front panel. Remote versions are also available which can support up to three multiplexers in a single slot.
-
Product
PXI/PXIe RF Multiplexer, Single 16-Channel, 3GHz, 50Ω, MCX
40-875A-101
Multiplexer Module
The 40-875A-101 (PXI) and 42-875A-101 (PXIe) are single 50 Ohm 16-channel RF multiplexers in a single slot. They have been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
Product
PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Dual Channel
42-204-002
Multiplexer Module
The 40-204-002 (PXI) and 42-204-002 (PXIe) are dual channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault.
-
Product
PXI 2 Amp Multiplexer, Single 16-Channel, 4-Pole
40-635A-003
Multiplexer Module
The 40-635A-003 is a single 16-channel, 4-pole MUX and is part of a range of Multiplexer modules available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC. The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
PXI/PXIe Microwave Multiplexer, Triple SP6T, 18 GHz, 50 Ω, SMA, Remote Mount, Failsafe
42-784B-023-E
Multiplexer Module
The 40-784B-023-E (PXI) and 42-784B-023-E (PXIe) are triple failsafe SP6T 18 GHz unterminated microwave multiplexers with remotely mounted relays. The 40/42-784B range is available with single, dual or triple, SP6T or SP4T multiplexers with front panel mounted or remotely mounted relays.
-
Product
PXI High Density MUX BRIC, 6-Chan, 160-Pole
40-570-016
Multiplexer Module
This range of High-Density Multiplexer is part of our BRIC family. These MUX's are designed to simplify the connection of a common set of test equipment to one of a number of different devices for testing (simultaneous multiple channel selection is also possible, without limitation). These multiplexers are ideal for applications where the equipment needs to conduct the same test process on a series of similar devices one at a time. They are available in a variety of configurations that allow testing with differing number of devices to be tested and different connection widths to suit differing test equipment pin counts. All version are supported in a BRIC8 construction that occupies eight PXI 3U mechanical slots, one of which provides the PXI interface and power.
-
Product
Single 16 to 1 Terminated 50 600MHz PXI RF Multiplexer
40-765-001
Multiplexer Module
This 4 to 1 multiplexer is part of a range of RF multiplexers available in the following configurations: dual, quad and octal 4 to 1, single, dual and quad 8 to 1, single and dual 16 to 1 and single 32 to 1. All multiplexers have the option of automatic terminations which offer advantages at system level by reducing the presence of standing waves in the system which can cause degradation in isolation and crosstalk.