Passive Intermodulation
1.) Protocol Independent Multicast - network routing over existing unicast framework. 2.) Passive InterModulation - RF interference generation condition.
-
Product
Passive Probe, 500 MHz, 10:1, 1 MOhm/10 MOhm
PP020-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
Passive Component Integration - MATRIQ
-
The Passive is a highly customizable benchtop accessory that can integrate the passive components of your choice for convenient storage and integration into your test set up.We can customize the Passive module with a wide range of passive components: WDM couplers, splitters, circulators, band-pass filters, PM beamsplitters, MUX, DeMUX and more.Our spec sheet contains a selection of popular configurations.Please contact us to discuss your specific requirements at sales@quantifiphotonics.com.
-
Product
HDLC RS-232 / RS-422 / RS-485 Passive Tap Module – USB Port
VERSA-TAP™
-
Versa-Tap protocol analyzer offers a powerful hardware solution that features state-of-the art electronics and provides exceptional data-logging/analyzer capabilities at a fraction of the cost of the nearest competitor.
-
Product
Passive Ionisation
-
Fraser Anti-Static Techniques Ltd
Versatile, low cost tools for neutralising high static charges on high speed web and sheet processing machinery.
-
Product
Passive Splitter for CATV/SATV
HGS01
-
Hangzhou Huatai Optic Tech. Co., Ltd.
*Zinc alloy die-casting chassis, surface with tin plating treatment.*Frequency range: 5-2400MHz. *Shielding degree 40-450MHz ≥ 75dB, 450-860MHz ≥ 65dB, 860-2400MHz ≥ 75dB. *All ports can be passed by maximum voltage: 24V, maximum current: 1A. *75Ω British F-type connector.
-
Product
Passive Probe, 10:1, 500 MHz, 1.3 M
N2873A
-
The N2873A passive probe offers DC to 500 MHz and 10:1 attenuation factor to address a wide range of measurement needs.
-
Product
3 Way GPS / GNSS Signal Splitter IP67 Outdoor, N Type, 1-2 GHz, 50 Ohm, Passive
GPS301
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo SplitterLow Insertion Loss (0.3 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy N Type Female (Jack) 50 Ohm
-
Product
Passive Probe, 10:1, 150 MHz, 1.2 M
N2841A
-
The Keysight N2841A low-cost passive probe provides a 10:1 attenuation and features a high input resistance of 10 MΩ. The probe can be adjusted for low-frequency compensation and high-frequency compensation.
-
Product
Passive Probe, 1:1, 20 MHz, 1.5 M
10070D
-
The Keysight 10070D 20 MHz passive probe is a great choice if you are looking for high quality at a very reasonable price. This general purpose probe is designed specifically to give you optimal performance with your 5000, 6000, 7000 Series, 54620 Series and 9000 Series oscilloscopes. Rugged enough for general-purpose measurements, the 10070D features a durable cable and a solid stainless-steel probe body encased with a hard, fracture-resistant plastic.
-
Product
T3DSO Passive Probe, 350 MHz, 10X, 10 MOhm, 300V/600V
T3PP350A
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.
-
Product
400 MHz High Voltage Passive Probe
HVP120
-
High voltage single-ended passive probes are suitable for a wide range of applications where ground-referenced high-voltage measurements must be made safely and accurately. There is also a sense pin to automatically configure the oscilloscope for use with the probe.
-
Product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP024-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP022-1
-
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
Product
Passive Optical TAPs
SplitLight
-
Designed for networks with high fiber counts, SplitLight is a patented and customizable 1RU solution offering the industry's highest density of Passive Optical Network TAPs, WDMs, and wavelength filters in a 1RU chassis. Using this platform, service providers, data centers, large enterprises, and government agencies can now monitor more fibers, or filter and route more wavelengths, than ever before while saving valuable rack space.
-
Product
5-slot ATX-supported 2U Butterfly PICMG 1.3 Bus Passive Backplane
FAB205
-
The FAB205 features a PICMG 1.3 CPU card slot, five 32bit/33MHz PCI slots, and built in a 24-pin ATX power connector and 8-pin connector for thermal detected board. The FAB205 is optimized to support AXIOMTEK's PICMG 1.3 system host boards, the SHB100 and SHB110, which are built around the PICMG 1.3 form factor. The FAB205 is compatible with the AX61220/AX61222 chassis.
-
Product
8-slot ATX-supported PICMG 1.3 Bus Passive Backplane
FAB116
-
The FAB116 features a PICMG 1.3 CPU card slot, one PCIe x16 slot, three PCIe x4 slots, three PCI, and built in a 24-pin ATX power connector and 8-pin connector for thermal detected board. Two high speed USB 2.0 ports are featured. The FAB116 is compatible with Axiomtek's AX60551 and AX60552 chassis.
-
Product
4 Way GPS / GNSS Signal Splitter Passive, 1-2 GHz, SMA, DC Block+200Ω Load 4 Ports
GPS412
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo splitterLow Insertion Loss (0.4 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy SMA Female (Jack) 50 Ohm
-
Product
6-slot ATX-supported PICMG Bus Passive Backplane (vertical)
ATX6022/6VP4
-
*1 PICMG, 4 PCI and 2 ISA*Compatible with AX61222TP/AX61220TP*Supports ATX power supply*For 2U chassis
-
Product
Thunderbolt 3 Type-C Cable, Passive 20 Gbps, 5A, 2m
785608-02
-
24-Pin USB-C Male to 24-Pin USB-C Male Thunderbolt™ Cable - The Thunderbolt 3 Male-to-Male Cable provides a USB-C connection for PXI chassis and controllers. This cable supports passive or active 40 Gbps or passive 20 Gbps data transfer speeds. The Thunderbolt 3 Male-to-Male Cable is available in 0.8 m or 2 m lengths. Thunderbolt and the Thunderbolt logo are trademarks of Intel Corporation or its subsidiaries in the US and/or other countries.
-
Product
Power Dividers/Combiners (Passive & Active)
-
PMI offers the highest quality power divider's and power combiner's for commercial and military applications in the frequency range of a few MHz to 40 GHz.
-
Product
Thick Film Passive Element
GBR-183
-
GBR-183 series resistors are made in a thick film technology, on ceramic substrates(Al2O3 -96%). Thick film resistors are characterized by a higher stability, and lower noises than a typical carbon resistors. The whole of resistor is encapsulated with epoxy resin by fluidization process. GBR-183 series elements are used both for general, and professional applications.
-
Product
Passive Imaging & Radiometers
PMMW
-
A low attenuation atmospheric window from 80-110 GHz (W Band) makes this band an ideal candidate for PMMW systems. Passive imagers operate by detecting naturally emitted thermal (black body) radiation from an object. Products available up to 345 GHz.
-
Product
8 Way GPS / GNSS Signal Splitter Passive, 1-2 GHz, SMA, DC Block+200Ω Load 8 Ports
GPS812
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo splitterLow Insertion Loss (0.6 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.15 : 1 avg)15 VDC & 75 mA max on DC block portsTri Alloy SMA Female (Jack) 50 Ohm
-
Product
SP500X , 500 MHz, ±300 V, 10X Attenuation, Single-Ended Passive Oscilloscope Probe
783629-01
-
The SP500X, or Multi-Contact Isoprobe IV - 10:1, is a standard passive probe with fixed 10x attenuation for oscilloscopes that provide 1 MΩ input impedance.
-
Product
GPS Antenna Signal Splitter 3 Way, N Type, Passive, L1 & L2, 50 Ohm
GPS300
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo SplitterLow Insertion Loss (0.3 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portsRoHS Compliant Splitter Construction
-
Product
Passive Probe Interface Adapter
CX1151A
-
The CX1151A is an adapter for passive probes for the voltage waveform measurements by the CX3300 series Device Current Waveform Analyzer.
-
Product
GPS Antenna Signal Splitter 3 Way, SMA Jack, Passive, L1 & L2, 50 Ohm
GPS310
-
INSTOCK Wireless Components, Inc
GPS L1 - L5, GLONASS, Galileo SplitterLow Insertion Loss (0.3 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.10 : 1 avg)15 VDC & 75 mA max on DC block portsRoHS Compliant Splitter Construction
-
Product
Intermodulation Distortion Measurements For P50xxA/B Streamline Series VNA
S97087B
-
Easily set up and calibrate swept intermodulation distortion measurements (IMD) measurements using the S97087B software application with the P50xxA/B Streamline Series VNA
-
Product
Passive Probe, 10:1, 300 MHz, 1.2 M
N2842A
-
The Keysight N2842A low-cost passive probe provides a 10:1 attenuation and features a high input resistance of 10 MΩ. The probe can be adjusted for low-frequency compensation and high-frequency compensation.





























