Electro-Chemical
chemical action when combined with electricity.
-
product
Scanning Electro-chemical Microscope
920D
The scanning electrochemical microscope (SECM) was introduced in 19891 as an instrument that could examine chemistry at high resolution near interfaces. By detecting reactions that occur at a small electrode (the tip) as it is scanned in close proximity to a surface, the SECM can be employed to obtain chemical reactivity images of surfaces and quantitative measurements of reaction rates.
-
product
Weld Testers
The Weld Tester is our most versatile electrochemical monitoring instrument. Housed in a substantial metal case with brushed anodised aluminium front panel and green military specification connectors this equipment looks functional and professional. The top row of connectors are exactly the same as provided on a Gill 12 whilst the bottom row are for the additional weld segments. Using the same Potentiostat, Galvanostat, Zero Resistance Ammeter with integrated Frequency Response Analyser and Sweep Generator as a Gill 12 allows all the tests supplied with the Gill 12 to be supplied with the Weld Tester.
-
product
EIS Battery Analyzer
BA8100
The BA8100 is designed to accurately measure the internal impedance of a single cell or battery stack with voltages as high as 80 V. In addition to impedance, auxiliary measurements include voltage, current, phase, capacitance, inductance, quality factor and more. With the provided software, the BA8100 can perform Electrochemical Impedance Spectroscopy (EIS) across a frequency range of 50 mHz to 10 kHz. The impedance spectrum can be evaluated through the Nyquist and Bode plot tools to determine effective series resistance (ESR) and track battery health. Included with the BA8100 is a self-test fixture to verify the instrument’s performance or compensate for resistance introduced by the test leads.
-
product
Constant Temperature Humidity Battery Test Chamber
Guangdong Test EQ Equipment co., Ltd.
- Battery-Specific Thermal Management: Dual-compressor cascade cooling (-40°C stability) and ceramic heaters for rapid high-temperature recovery.- Precision Electrochemical Control: Integrated battery cyclers with CAN/Modbus protocols, supporting SOP (State of Power), SOH (State of Health), and DCR (Direct Current Resistance) monitoring.- Safety-Centric Design-meet Hazard Level: Chambers are designed with Fire-resistant stainless steel interior, fire suppression,nitrogen purge system, and emergency power cutoff for thermal runaway prevention .- Data Acquisition & AI Analytics: Real-time logging of voltage, current, temperature, and pressure via LabVIEW/Python APIs. AI-driven anomaly detection reduces test cycles by 30%.- Energy Efficiency and Energy Storage: Heat recovery during discharge cycles cuts energy use by 25% (ISO 50001 compliant).
-
product
Scanning Electrochemical Systems
The VersaSCAN is a single platform capable of providing spatial resolution to both electrochemical and materials-based measurements. Each VersaSCAN is based on a common high-resolution, long-travel, closed-loop positioning system mounted to a vibration-resistant optical base. Different auxiliary pieces are mounted to the positioning system. These ancillary pieces (e.g., an electrometer, piezo vibration unit, or a laser sensor) provide functionality to the positioning system for different scanning probe experiments. VersaSTAT potentiostats and Signal Recovery Lock-in Amplifiers are integrated via ethernet control to make accurate measurements of these small signals.
-
product
Carbon Monoxide Detector, CO
ENVIROMUX-CMD
Continuous air monitoring. Pre-set alarm points alert at: 70 ppm after 60 to 240 minutes; 150 ppm after 10 to 50 minutes; and 400 ppm after 4 to 15 minutes. Flush or surface mount. Test functionality of electrochemical CO sensing cell. Connect to RJ45 or digital input sensor ports. Screw terminal. To connect to the RJ45 inputs use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal. Maximum cable length: 1000 ft (305m). LED indicators for operation status and system test. Powered by ENVIROMUX-2D/5D/16D. Regulatory approvals: UL.
-
product
Handheld Electrochemical Battery Analyzer
EC-Series
Global Energy Innovations, Inc.
The EC1000™ and EC2000™ are the only handheld, Multi-Frequency, ElectroChemical Battery Analyzers on the market using CELScan™ technology. This means they can report both the Electrical (Impedance & Voltage) and Chemical (Sulfation and Dryout) properties of lead acid batteries (VLA, VRLA, GEL). Other battery types (NiCd, NiMH, Lithium-Ion and others) may also be tested using the EC1000™ and EC2000™.
-
product
Continuous LPR Corrosion Meter
MS2001L
The MS2001L is a microprocessor-based, field-mountable corrosion rate meter. This versatile instrument measures the instantaneous corrosion rate and electrochemical current between the electrodes of any standard 2-electrode linear polarization resistance (LPR) probe. Corrosion rate is displayed on the LCD display.
-
product
Radiometer Analytical Probes
Radiometer Analytical develops and manufactures an extensive range of electrochemical electrodes - combined pH, glass or reference electrodes, metal electrodes, ion-selective electrodes and conductivity cells - for every application and budget.
-
product
Process Percent Oxygen Analyzer
GNL-IN962
Shanghai ChangAi Electronic Science & Technology Co.,Ltd
GNL-IN962 oxygen analyzer is an intelligent oxygen analyzer that is based on microprocessor, keeping gas electrochemical sensor as measuring unit with high intelligence, accuracy and long service life. It has been used in oxygen concentration in many industries under various environments. - See more at: http://en.ci-ele.com/79b7fcd3-aee7-30a4-9cf8-76748ef33dcc/16c2beac-ce45-7aaa-50ed-8b48397f3a15.shtml#sthash.1UMwSmEm.dpuf
-
product
Oxygen/Combustibles Analyzer
DT3006
The Datatest Model DT3006 Oxygen/CO analyzer is a microprocessor based instrument. It has a zirconia sensor for oxygen and an electrochemical sensor for carbon monoxide. Excellent trim control and boiler safety instrument with great reliability and stability thanks to the micro controller.
-
product
Electronic Loads
AMETEK Programmable Power, Inc.
Electronic loads have found a variety of applications ranging from power converter testing to current modulation. A large range of power sources can be tested using an electronic load from converters, inverters and UPSs to electrochemical sources such as batteries and fuel cells.
-
product
Tribocorrosion Tester
ASTM G119
Tribocorrosion involves studying Wear Evaluation of Protective Coatings. It involves mechanical and electrochemical interactions between components in motion. Rtec Tribocorrosion modules measures inline current, voltage, friction, wear, temperature , down force, ear, acoustic emissions at all times. Currently used by several Fortune 500 firms globally.
-
product
Potentiostat/Galvinostat
EZstat Pro
The EZstat Pro potentiostat/galvanostat uses a versatile menu-driven waveform generator (periodic or aperiodic) with preset battery cycling, Tafel plots, and cyclic voltammetry procedures.Users can program sequences of steps blending current and potential control with a resolution of 8 uS/point. EZstat Pro can perform electrochemical impedance spectroscopy (EIS) and uses active IR compensation. The instrument can interface with the EZpump peristaltic pump for flow batteries and fuel cells.
-
product
DigiElch Electrochemical Simulation Software
DigiElch 8 from ElchSoft is an electrochemical simulation program for a wide variety of systems involving charge transfer reactions, adsorption, and charge-coupled chemical reactions such as proton-coupled electron-transfer (PCET). A demonstration version of DigiElch 8 is available.
-
product
Surface Insulation Resistance Testing
AutoSIR2™
One AutoSIR chassis can hold between 1 to 16 measurement cards and can monitor up to 256 x 2-point test patterns or 78 x 5-point test patterns, or 32 x 9-point test patterns at selectable intervals from minutes to days. Each channel is current limited (1 M Ω), ensuring that dendrites are preserved for failure analysis. The frequent monitoring capability provides a full picture of the electrochemical reactions taking place on a circuit assembly, and provides early trend analysis enabling tests to be curtailed, thus saving considerable test time and money.
-
product
Dynamic UPS
ROTOBLOC® RBT SERIES 400 - 2000 kVA
The RBT system consists of a standard synchronous generator with no special windings and a simple steel flywheel. The low speed shaft extends bearing life and reduces maintenance. The ROTABLOC® machine is very robust as critical functions do not use fragile components such as power electronics, power capacitors, electro-chemical batteries, active magnetic bearings, electro-mechanical or mechanical friction clutches.
-
product
Materials And Chemical Analysis
Anderson Materials Evaluation, Inc.
Materials characterization, failure analysis, quality control, and materials and process development services are offered. Our analytical techniques allow us to assess elemental and chemical material composition, thermal properties, coating thickness, electrochemical properties, surface chemistry, surface wetting, corrosion rates and pitting potentials, contamination and degradation problems, metallography, fractography, phase transitions, static coefficient of friction, adhesive bonding strength and causes of adhesive bonding failures, surface tension and surface energy, tensile and compressive strength, bend deflection, lapshear strength, elasticity properties, UV and visible light absorption and reflection, density and porosity, and many other material properties integral to improving your products.
-
product
EIS Interface (Electrochemical Impedance Spectroscopy)
BATT470m
The BATT470m electrochemical impedance analysis interface (EIS) provides an easy to use battery/cell impedance test platform for the electrochemical industry. Utilizing the highly accurate PSM3750 frequency response analyzer from N4L, the BATT470 provides impedance measurement of batteries/cells up to 100V DC. With a frequency range of 100mHz to 1MHz, the BATT470m covers a wide range of applications. Our software package - PSMComm2, featuring “EIS” mode, displays the in-phase and quadrature impedance of the cell in Nyquist form as well as overall impedance (Z), in bode form.
-
product
SUGGESTED REPLACEMENT/UPGRADE C165+*
C165
UEi Test & Measurement Instruments
The C165 Combustion Analyzer with EOS Technology and High Altitude Compensation eliminates the number one hassle experienced by HVAC contractors, the cost and down time of replacing the O2 sensor. The EOS technology for combustion analysis replaces the everyday electro-chemical O2 sensor with the EOS technology CO2 sensor lowering the cost of ownership and includes High Altitude Compensation
-
product
Single Channel Potentiostats
VersaSTAT Series
This family of instruments combines our option-based hardware and software platforms to create the most popular line of potentiostats. Introduced for the majority of researchers doing typical electrochemical experiments, this entire series gained a key improvement in 2018. As of August 1st, 2018, all VersaSTAT models have ± 2 Amp capability standard. Users can now study larger samples at faster rates.
-
product
Electrochemical Measurements
A portable pH-meter from CHAUVIN ARNOUX is ideal for mobile applications: in the field, in the laboratory or in production. It can be used for quick, accurate, professional measurements of pH, Redox potential and temperature.
-
product
Potentiostat Galvanostat
PARSTAT 4000A
The PARSTAT 4000A stands alone in its ability to deliver high compliance voltage and wide dynamic current range, as standard, to cover a range of applications. The PARSTAT 4000A builds on PAR's history as the world-leader in DC electrochemical measurements and takes advantage of a common R/D team with Solartron Analytical, the world-leader in Frequency Response Analyzer (FRA) technology, to provide a best-in-class complete system.
-
product
Trace Moisture Analyzer
PPM1
Model PPM1 is a trace moisture analyzer designed specifically for monitoring moisture levels in dew point and PPM units. This trace moisture analyzer utilizes an electro-chemical (P205) sensor in combination with a proprietary semi permeable diffusion membrane.
-
product
Flow Cell Kit
QCMT
The quartz crystal microbalance (QCM) technique under electrochemical frequency is very useful to determine many compounds such as metal proteins, metal ions and thiol-conjugated oligonucleotides.
-
product
S Sensor
Z-Gard S Sensor
The Z-Gard S Sensor is designed to detect the presence of carbon monoxide, nitrogen dioxide and combustible gases in air. These sensors employ solid state, electrochemical or catalytic sensors which generate a representative output signal proportional to the calibrated operating range.
-
product
Water Quality Products
When you need to perform critical water testing, look to us for an extensive selection of electrochemical meters, controllers, probes, electrodes, test kits, buffers, and standards. Our field and laboratory instrumentation include water analysis instruments for dissolved oxygen, temperature, pH, conductivity, salinity, and turbidity.
-
product
Trace Oxygen Analyzers
Alpha Omega Instruments trace oxygen analyzers and transmitters incorporate an advanced electrochemical sensor that provides exceptional life, accuracy, and stability. Alpha Omega Instruments electrochemical sensors provide as much as three times the life of conventional “fuel cell” type sensors. And, if you are looking to measure from parts per billion to 100%, Alpha Omega Instruments offers a high-performance zirconium oxide oxygen sensor.
-
product
Bipotentiostat
700E
The Model 700D series are computerized general purpose potentiostat / bipotentiostat / galvanostat instruments. A typical application involves a rotating ring-disk electrode (RRDE), but these systems can also be used for other applications where dual channel measurements are essential, such as dual channel electrochemical detection.
-
product
Percent Oxygen Sensors
At Process Sensing Technologies (PST), we offer replacement electrochemical oxygen sensors compatible with major fixed and portable oxygen analyzers in challenging industrial environments. Tailor your solution with our versatile housing options, allowing you to specify either a 2-ring or connector design.