Electro-Chemical
chemical action when combined with electricity.
-
Product
Electronic Loads
-
AMETEK Programmable Power, Inc.
Electronic loads have found a variety of applications ranging from power converter testing to current modulation. A large range of power sources can be tested using an electronic load from converters, inverters and UPSs to electrochemical sources such as batteries and fuel cells.
-
Product
Cells and Electrodes
-
Electrochemical cells are designed to their special purpose. The method, the matter and their reactions as well as the environmental conditions define the limitations and demands for electrochemical cells and the electrodes. Standard corrosion testing cells may have a large volume, since corrosion products shall not change the solution grossly during the test. On the other hand, it may be valuable to collect corrosion products - then a very small volume is desired ("eluation cell"). Special corrosion tests for pitting reqiure a setup where undesired crevice corrosion is excluded ("Avesta cell" , "Quarfort Cell" or "Flushed port cell". Or you want to investigate in crevice corrosion, then the cell design should meet such conditions. Have a look to the variety of cells shown here, and call us if you have a special task where a fresh design is required.
-
Product
PARSTAT MC Multichannel Potentiostat
-
The PARSTAT® MC (PMC) is the most modular and robust multi-channel electrochemical testing platform on the market.The PMC chassis provides a robust environment up to 10 modules, up to 20 channels.
-
Product
Constant Temperature Humidity Battery Test Chamber
-
Guangdong Test EQ Equipment co., Ltd.
- Battery-Specific Thermal Management: Dual-compressor cascade cooling (-40°C stability) and ceramic heaters for rapid high-temperature recovery.- Precision Electrochemical Control: Integrated battery cyclers with CAN/Modbus protocols, supporting SOP (State of Power), SOH (State of Health), and DCR (Direct Current Resistance) monitoring.- Safety-Centric Design-meet Hazard Level: Chambers are designed with Fire-resistant stainless steel interior, fire suppression,nitrogen purge system, and emergency power cutoff for thermal runaway prevention .- Data Acquisition & AI Analytics: Real-time logging of voltage, current, temperature, and pressure via LabVIEW/Python APIs. AI-driven anomaly detection reduces test cycles by 30%.- Energy Efficiency and Energy Storage: Heat recovery during discharge cycles cuts energy use by 25% (ISO 50001 compliant).
-
Product
Trace Oxygen Analyzers
-
Alpha Omega Instruments trace oxygen analyzers and transmitters incorporate an advanced electrochemical sensor that provides exceptional life, accuracy, and stability. Alpha Omega Instruments electrochemical sensors provide as much as three times the life of conventional “fuel cell” type sensors. And, if you are looking to measure from parts per billion to 100%, Alpha Omega Instruments offers a high-performance zirconium oxide oxygen sensor.
-
Product
Impedance Spectroscopy
NuVant EZware-EIS Software Package
-
The NuVant EZware-EIS software package activates Electrochemical Impedance Spectroscopy on the EZstat-Pro, Powerstat-05 and -20 potentiostat/galvanostats. EZware-EIS exports the impedance data to a file format to accommodate free third party EIS analysis software. EZware-EIS is a user-friendly interface that allows selection of the proper scanning parameters, collect the impedance spectra, display data in Nyquist and/or Bode plots and export data in the proper data format for use in EIS analysis software.
-
Product
S Sensor
Z-Gard S Sensor
-
The Z-Gard S Sensor is designed to detect the presence of carbon monoxide, nitrogen dioxide and combustible gases in air. These sensors employ solid state, electrochemical or catalytic sensors which generate a representative output signal proportional to the calibrated operating range.
-
Product
Potentiostat/Galvinostat
EZstat Pro
-
The EZstat Pro potentiostat/galvanostat uses a versatile menu-driven waveform generator (periodic or aperiodic) with preset battery cycling, Tafel plots, and cyclic voltammetry procedures.Users can program sequences of steps blending current and potential control with a resolution of 8 uS/point. EZstat Pro can perform electrochemical impedance spectroscopy (EIS) and uses active IR compensation. The instrument can interface with the EZpump peristaltic pump for flow batteries and fuel cells.
-
Product
PowerNet Tester
-
The PowerNet Tester (BNT) is designed to test batteries, ultracaps and all other types of electrochemical power sources for 14 V and 42 V power net systems. Designed to test vehicle system batteries for 14V and 42V power net systems. But they may also be used for testing all other types of electrochemical power sources just by setting the required current and voltage values.
-
Product
IDA Electrodes
-
Interdigitated Array (IDA) electrode is an electrode developed for electrochemical measurements to be performed in a very small quantity of the sample. IDA electrode could be applied for the detection and reaction analysis of the compounds in a small quantity of the sample. IDA electrode is a microelectrode pattern fabricated by using the lithography technology. The Electrodes are composed of 65 pairs. In each one of the pair has a function of the oxidation and reduction electrodes.
-
Product
Cell Stand
CS-3A
-
The CS-3A Cell Stand is adopted with CHI series Electrochemical Analyzers and other apparatus directly. The cell is enclosed in a Faraday cage to reduce electrical interference. A built-in gas control allows purging a sample. Gas line is provided to purge next sample, while analyzing the present sample separately, thus increasing productivity. Magnetic stirrer allows for controlling the mixing of the sample for experiments requiring mass transport of electrolyte or analyte to the electrode surface. Cell top positioner with detachable cell cap allows easy removal and replacement of the cell vial as well as the electrodes for rinsing, cleaning, and replacement.
-
Product
Potentiostat/Galvinostat Electrochemical Instuments
-
- 16 bit DAQ card- 250 kS/s aggregate- 125 kS/s per channel- Step Impedance Spectroscopy- Electrochemical impedance spectroscopy (EIS) 0.01 – 10 kHz- 5-lead cable (3 electrodes, sense & ground)- LabVIEW EZware software- Free software upgrades. 1 year parts and labor warranty- EIS information
-
Product
Radiometer Analytical Probes
-
Radiometer Analytical develops and manufactures an extensive range of electrochemical electrodes - combined pH, glass or reference electrodes, metal electrodes, ion-selective electrodes and conductivity cells - for every application and budget.