Detectors
register the presence of a stimuli.
See Also: Metal Detectors, Particle Detectors, Sensors, Charge Sensitive Preamplifiers, Checkers
-
Product
Power Detectors
-
Get accurate measurements with fast response times with our thermopile or pyroelectric power meters. Available with various absorbers, with the highest damage thresholds you can find in their category, our power meters cover a wide range going from the nanowatts to multi-kilowatts.
-
Product
Pixie Hybrid
-
The Pixie Hybrid is a multichannel data acquisition system for fast radiation detectors in nuclear physics and other applications requiring coincident radiation detection, and provides the following advantages:*Compatible with PXI-Express Hybrid or PXI chassis*Sophisticated data acquisition*Advanced pulse shape analysis*Scalability; several modules can be combined into larger system
-
Product
Micro Capacity Type Torque Detector
MD Series
-
The MD series torque detector is designed to measure the torque output from compact & precision type motors used in the electric & electronics industry, the automotive industries and so on, featuring outstanding low inertia and low starting torque. With the phase differential system, it can realize low capacity torque measurement as small as 0.001mNm.
-
Product
Magnetic Particle Flaw Detector
MT-1A
-
MT-1A digital portable magnetic flaw detector, adopts large capacity lithium battery power supply. DC is exchanged into AC by the inverter and the phase shifted signal processor to provide power for the detector, it solves the shortcomings of traditional magnetic particle detector relying on the 220V power supply. It has low power consumption and can continuous work for more than 4 hours. The battery can be charged while working or off. It can real-time monitoring, process image, save data, print the test report, track inspection results, meet the requirements of standard operation and management. Especially suitable for the field without power supply field testing and high-altitude operations, it realizes the innovation of magnetic powder digital inspection.
-
Product
Digitizer
761 Family
-
The 761 is the family of CAEN Waveform Digitizer with the highest sampling rate Flash ADC (10 bit @ 4GS/s). It can record fast signals from fast organic, inorganic and liquid scintillators coupled to PMTs or Silicon Photomultipliers, Diamond detectors and others, and save them with high efficiency and precision for advanced timing analysis. The acquisition can be externally vetoed/gated. Multiple boards can be synchronized to build up complex systems.
-
Product
Low-Barrier Schottky Diode Detector, 10 MHz to 18 GHz
8470B
-
The Keysight 8470B 18 GHz Low-Barrier Schottky Diode (LBSD) detector has been widely used for many years in a variety of applications including leveling and power sensing. It offers good performance and ruggedness. Matched pairs (Option 001) offer very good detector tracking. A video load (Option 002) extends the square-law region to at least 0.1 mW (-10 dBm).
-
Product
Deep Cooled NIR Scientific Cameras
Synapse InGaAs/Symphony II InGaAs
-
HORIBA Scientific offers a complete line of spectroscopic multi-channel detectors for scientific research. For spectral detection from UV to near-IR, two dimensional CCDs and indium gallium arsenide linear arrays offer a faster acquisition option over single point detectors with relatively high sensitivity. Coupled with HORIBA’s range of aberration corrected, flat field imaging spectrographs, custom spectroscopy packages can be assembled for a variety of applications.
-
Product
Short Hot Stick
HS-800
-
Standard Electric Works Co., Ltd
● Single foamed hot stick.● Universal sunrise fitting on the head to fit special tool fittings.● Rated at 100 kV per 300mm (5 minutes).● Can be connected to 275 HP HV proximity detector, 21X HVD capacitive HV detector and 277 HP Non-contact HV detector.● Meets IEC 60855.● Reasonable price.● Accessories
-
Product
Analog Ionizing Radiation Detectors
-
A great general purpose analog radiation detector. Detects from 0-50 mR/hr.
-
Product
Scanning Slit Beam Profilers
-
DataRay manufactures two types of scanning slit beam profilers: the patented BeamMap series, which offers real-time M², divergence, focus and alignment management, and the Beam’R series which provides affordable, compact, and precise beam profiling. All of our scanning slit beam profilers are available with Si, Ge, and InGaAs detectors, covering wavelengths from 190 nm to 2500 nm.
-
Product
Cryogenic Hygrometer
CR - 2
-
Buck Research Instruments, LLC
The CR-2 exhibits the same wide range, fast response and high reliability as the CR-1A, but it is designed specifically for aircraft and similar high-stress applications. Instead of using Liquid Nitrogen (LN2), mirror cooling is accomplished using a tactical cryocooler, which is a high-tech device used primarily to cool IR detectors in missiles and tank turrets to LN2 temperatures.
-
Product
Specialty Instruments
-
Specialty Instruments represents a mixed variety of special-purpose professional-quality instruments. It includes a stroboscope, a refrigerant charging scale, two lightning detectors, a microwave leakage detector, a vacuum meter, and handheld and USB vibration data loggers.
-
Product
Precipitation Detector
HD2013.3
-
Rain, snow, hail detector - Modbus-RTU or 4-20mA or 0-10V or contact output.
-
Product
F/V Converter
FV-1100
-
The FV-1100 receives signal from a rotation detector or a similar device and outputs DC current or voltage signal proportional to its frequency. As the fluctuation of the input frequency signal is continuously converted to DC voltage, it is useful for measurement and recording of transient phenomena such as fluctuation of rotating speed, current velocity, frequency.
-
Product
AE Valve Leakage Detector
SVLD1
-
Through acquisition, processing, and calculation of acoustic emission signal of the valves, SVLD1 could generated root-mean-square voltage (RMS), average signal level (ASL) and power (P) parameters as which could judge the leakage. Meantime, you can pre-calibrate the leakage quantity for the specified valve, and calibration curve of parameters and leakage could be calculated by SVLD1, so as to give the valve leakage reference value during the test.
-
Product
Gas Detector
-
Shenzhen UYIGAO Electronic Technology Co., Ltd
Gas detector is a portable detector for detecting carbon monoxide (CO) gas.
-
Product
High Definition LWIR Science-Grade Camera
FLIR X8580 SLS™
-
The FLIR X8580 SLS is a high-speed, high definition longwave IR camera designed for scientists and engineers who need to capture detailed imagery of fast events, perform custom radiometric measurements, or detect points of failure in composites, solar cells, and electronics. This thermal imaging camera combines 1280 × 1024 resolution from the SLS detector with high-speed frame rates to offer shorter snapshot speeds and wider temperature bands for crisp stop motion imagery of high-speed events. With a four-position motorized filter wheel and support for FLIR motorized focus lenses, the X8580 SLS will provide high quality recordings, save time, and mitigate frustration in dynamic acquisition environments.
-
Product
Wall Searching Metal Detector
HHB C
-
A Wall Searching Metal Detector, also known as a stud finder or wall scanner, is a tool used to locate hidden objects behind walls, such as metal pipes, electrical wires, and wooden studs.
-
Product
2 Channel 10 bit 4GS/s Digitizer
V1761
-
The V1761 comes in a VME form factor with 2 input channels. The communication to and from the board is provided through VMEBus and Optical Link interfaces. It can record fast signals from fast organic, inorganic and liquid scintillators coupled to PMTs or Silicon Photomultipliers, Diamond detectors and others, and save them with high efficiency and precision for offline advanced timing analysis.
-
Product
Resets And Voltage Detectors
-
ST’s reset and voltage detector ICs provide basic voltage monitoring (low-voltage detect POR-LVD function) and reset timing for power-on resets. These devices offer:
-
Product
Thermo-Electrically Cooled Dual Mode Analog/Photon Counting Photmultiplier Tube (PMT)
CoolOne
-
For spectroscopy and microscopy experiments in the UV/Vis/NIR region of the spectrum, a photomultiplier tube (PMT) is the ideal detector for quantitative low light level measurements. A PMT is extremely sensitive, with very wide dynamic range so it can also measure high levels of light. PMT’s are also very fast so rapid changes in optical signals can be reliably monitored. As a practical matter, PMT’s are durable, long-lived, and economical.
-
Product
Capacitance Bridge
1620
-
The GenRad 1620-A Capacitance Measuring System is a self-contained assembly of the GR 1615-A Capacitance Bridge with appropriate oscillator and null detector for measurements at 11 frequencies between 20 Hz and 20 kHz. For applications requiring other or higher frequencies, to 100 kHz, the 1615-A bridge can be supplied separately and the oscillator and detector selected to meet your needs.
-
Product
CBRN Detectors
RIID
-
A Radioisotope Identification Device (RIID) is a small, lightweight, portable instrument that identifies radioactive materials by measuring the energy of gamma rays they emit. RIIDs can also perform spectroscopic analysis to distinguish between different radioactive isotopes.
-
Product
Magnetic Flaw Detector
CDX-Ⅲ
-
magnetic particle flaw detector is the self-designed magnetic participle flaw detector of MITECH CO.,LTD. With small size, light weight, easy operation, multifunction in one unit. The detector can equip A, D, E O four types of probes to realize the functions of magnetic clamp detection, electromagnetic yoke detection, cross magnetic yoke detection, ring detection. It is the necessary detector to do quality control, safety check, life evaluation in the fields of petrol, chemicals, metallurgy, shipbuilding, aviation, railway etc
-
Product
Energy Probes
RjP-400 Series
-
The RkP-400 Series probes consist of a compact detector assembly, or head, and a preamplifier housed in a separate enclosure. The external dimensions of all the 400 Series Probes are the same, with identical detector planes, allowing for easy interchange of probes in an experiment. The heads have both ¼-20 and M6 tapped holes, a built-in 1" (25mm) filter holder, and a side-mounted BNC connector. Probe specific data, including spectral response curves and calibration dates, is stored in the preamplifier for access by the instruments.
-
Product
Enameled Wire Portable Pinhole Tester
-
Shanghai Dean Electrical Co., Ltd
DZK high and low voltage (portable) pinhole detector is designed and produced in accordance with GB/T4074.5-2008 standard, and can be used by users to monitor the continuous performance of the paint film of the product in real time during production and use. . It takes into account the detection function of the traditional high-voltage paint film continuity tester, and the advantages of being easy to move and replace the use position (the whole machine weight is less than 5KG and can be equipped with lithium batteries), which is convenient for users to detect multiple environments and multiple cables. use.
-
Product
Carbon Monoxide Detector, CO
ENVIROMUX-CMD
-
Continuous air monitoring. Pre-set alarm points alert at: 70 ppm after 60 to 240 minutes; 150 ppm after 10 to 50 minutes; and 400 ppm after 4 to 15 minutes. Flush or surface mount. Test functionality of electrochemical CO sensing cell. Connect to RJ45 or digital input sensor ports. Screw terminal. To connect to the RJ45 inputs use CAT5/5e/6 cable terminated at one end with RJ45 connector. Connect the un-terminated end to the sensor screw terminal. Maximum cable length: 1000 ft (305m). LED indicators for operation status and system test. Powered by ENVIROMUX-2D/5D/16D. Regulatory approvals: UL.
-
Product
O/E Converter
TIA-4000
-
The TIA-4000 is comprised of a fibre coupled InGaAs APD detector combined with a variable reverse bias voltage network and fast transimpedance amplifier. The output of the unit is brought out to a type K female SMA connector. Light falling on the detector generates a positive-going proportional current. This current, multiplied by the transimpedance produces a voltage that is proportional to the light incident on the detector surface.
-
Product
X-ray Analytical Microscope Super Large Chamber Model
XGT-9000SL
-
- Large chamber capacity (W x D x H) : 1030 mm x 950 mm x 500 mm- X-ray shield complying with JAIMAS0101-2001/ IEC1010-1 to protect you from X-ray exposure- Mapping area size up to 350 x 350 mm2- <15 µm spot size with ultra-high intensity without compromising sensitivity and spatial resolution- Dual types of detectors for transmission and fluorescent X-rays- Detectable element range down to C with a light element detector and He purge module
-
Product
Detector Modules
-
Detector modules, into which the entire drive electronics have been integrated, were developed to facilitate the application of detectors. PIN modules and APD modules are available along with intelligent sensors which are – thanks to their interfaces – ready for application in Industry 4.0.





























