Com-Power Corporation
Com-Power Corporation has been a supplier of instrumentation for EMI / EMC Testing (electromagnetic compatibility), telecommunication ( Part68 ) and product safety ( UL / IEC CSA) testing since 1989.
- (949) 459-9600
- (949) 635-0329
- sales@com-power.com
- 1679 Placentia Avenue
Costa Mesa, California 92627
United States of America
-
product
Combilog Antenna
AC-220
The AC-220 Combilog antenna is for EMC emission and immunity up to 2 GHz.. It combines the electrical properties of two antenna (biconical and Log ). It reduces overall testing time by 20 - 30% due to antenna switching. It is Optimized for emission measurements, but can handle up to 500 Watt CW, making it suitable for most immunity measurements . Each antenna is individually calibrated at 10 meters and the data included the purchase price.
-
product
Preamplifiers
Com-Power broadband high gain preamplifiers were designed for electromagnetic interference (EMI) testing and certification. EMC test labs use preamplifiers to improve sensitivity of the test system during EMI radiated emissions measurements. Without a high gain preamplifier, signals picked by the antenna that have amplitudes below the noise floor of the test system cannot be measured. The preamplifier gain has minimum variations for the entire operating frequency range for accurate emissions measurements. The Com-Power preamplifiers were primarily intended for EMC applications. However, it can be used for other applications that require signal amplification.
-
product
Emissions Test System
PC-114
Perform Radiated & Conducted EMI pre-compliance testing at your facility up to 1 GHz. Com-Power PC-114 EMI emissions test system is a ideal solution performing pre-compliance EMC testing from 9 kHz - 1 GHz.. It has essential equipment needed for radiated and conducted EMI emissions measurements. The system includes a spectrum analyzer, antennas, near field probes, a preamplifier, LISN and a non conductive antenna tripod. Pre-compliance testing in EMC is a commonly used term not easy to define. In general, it implies testing done prior to formal testing for legal compliance. Formal legal compliance is performed at a facility designed and equipped with test instrumentation that is fully compliant with the applicable EMC standards. Such facility and instrumentation is capital intensive and can be expensive even to rent and not easily available. Compliance testing is performed per exacting requirements of the Standards and other reference documents adhering to the test methods and last detail. In addition, the test facility may require to be accredited by an accreditation body such as NVLAP, A2LA. Often it is desirable to know prior to compliance testing at such facility, whether a product is close to compliance and also how close. Pre-compliance testing is specially useful for specifications such as FCC, Part 15, EN 55022 or EN 55011 (CISPR 22 or CISPR11). Pre-compliance testing usually means using the full compliance methods but making a few educated compromises in use of site or equipment to reduce costs and testing time. Here are some benefits of pre-compliance testing.
-
product
CDNs
T Series
The T series CDNs are for cables with unshielded balanced conductor pairs typically found in ISDN, DSL and Ethernet data transfer applications.
-
product
Dipole Antenna
AD-100
The Tuned Dipole Antenna model AD-100 is a reference antenna set specified in many EMC standards. It is used in the frequency range of 30 MHz to 1 GHz. This set consists of four baluns and was designed according to American National Standard C63.4. This reference antenna set is used for EMC test site calibrations and for calibrating other antennas, because it is considered a standard antenna according to ANSI C63.5 standard.
-
product
CDNs
S Series
The S series CDNs are for shielded cables with single or multiple conductors. These CDNs are supplied with professional audio (RCA), D type and Centronics connectors.
-
product
Spectrum Analyzer
SPA Series
The SPA-series high performance, low cost, easy to use, portable spectrum analyzers are ideal for a pre-compliance laboratory. All three models feature a wide frequency range and low noise floor to increase system sensitivity and system to noise ratio. An advanced, easy to use interface makes your work simple by putting the features you need at your fingertips.
-
product
Comb Generators
As an EMC testing lab, the accuracy of your results is key to your reputation. Maintaining this accuracy requires properly calibrated quality equipment. Comb generators are an important piece of EMC radiated emissions testing equipment - one that can save you time and money by reducing your reliance on full, annual recalibrations of your site and instrumentation.
-
product
Biconical Antennas
Biconical antennas are used for emissions and immunity testing to meet various EMC standards specified by FCC, CISPR and EN. The broadband characteristics of the biconical antenna make it a good choice for making sweep measurements and for automated measurement systems.
-
product
Active Loop Antenna
AL-130R
Also known as Magnetic Loop Antenna, the AL-130R is compliant with CISPR 16-1-4. It is ideal for emissions measurements as required by various EMC standards such as FCC 18, CISPR 11, CISPR 13, CISPR 14, CISPR 32 and many more. The built-in, low-noise preamplifier, increases overall measurement sensitivity as well as the overall signal to noise ratio. As per ANSI C63.4-2014, the use of active loop antenna for compliance testing is permitted in a non-sheilded environment ONLY if the saturation indicator is continuously monitored during the course of testing. Com-Power’s Remote Antenna Interface (RAI-100) comes in very handy for this application. It is a compact controller which can be used to enable/ disable RF measurement circuit and monitor saturation and battery low conditions remotely via a fiber optic cable up to 30 mtrs in length.
-
product
Horn Antennas
Horn antennas can be used for emissions and immunity testing. These antennas are constructed using light weight aluminum with a corrosion resistant conductive coating for indoor or outdoor use. Each antenna is individually calibrated. The calibration data and certificate will be shipped with each antenna.The high gain reduces input power requirements to generate high electromagnetic field levels for immunity testing. High gain also increases antenna sensitivity to low level signals.
-
product
Line Impedance Stabilization Networks
LISN
LISN stands for 'Line Impedance Stabilization Network'. Com-Power offers a line of LISNs developed for conducted emission testing according to the most commonly adopted EMC specifications like CISPR, FCC, ISO, EN, RTCA DO-160 and MIL-STD 461D. The LISN circuit is designed and constructed to meet the performance criteria given by these standards.
-
product
Log Periodic Antennas
Log Periodic antennas allow quick sweep measurements without a band break. This feature makes it convenient to use the Log Periodic antenna with a automated emissions or immunity measurement system. The size of the antenna also allows it to be used in a small area like a shield room.
-
product
Transient Limiters
Transient limiter LIT-153A and LIT-930A protects a spectrum analyzer input from high-level transients from the line impedance stabilization networks during EMC conducted emissions testing. It has a combined frequency range of 9 kHz to 30 MHz. The built in high pass filter helps reduce 50/60 Hz line feed through. (see application notes)
-
product
Impedance Stabilization Networks
ISN
They are required for the measurement of conducted common mode noise on Telecom Cables of Information Technology Equipment (ITE). These measurements are necessary to meet the requirements specified in CISPR 22 and CISPR 32 standards.















