Chroma Systems Solutions, Inc.
From power conversion to battery to electrical safety, our test systems will maximize your time, improve your validation process, increase your throughput and help the world’s leading R&D labs with testing applications as diverse as your requirements.
- 949-600-6400
- 949-600-6401
- 19772 Pauling
Foothill Ranch, CA 92610
United States of America
-
Product
Programmable AC Electronic Load
63800
-
Chroma Systems Solutions, Inc.
The Chroma 63800 Loads can simulate load conditions under high crest factor and varying power factors with real time compensation even when the voltage waveform is distorted. This special feature provides real world simulation capability and prevents overstressing resulting in reliable and unbiased test results.
-
Product
Battery Cell Surge Tester
Chroma 19311
-
Chroma Systems Solutions, Inc.
The 19311-10 has 10 channels, which can test up to 9 battery cells via scanning test, with a single unit. It can support up to 25 channels for testing up to 24 cells in a sequence by connecting with an external scanner (A190362). The test speed of the multicell scanning test by 19311-10 is extremely efficient, saving test time, and decreasing labor costs. It also increases the production capacity of the production line.
-
Product
Hipot & Safety Test
-
Chroma Systems Solutions, Inc.
Electrical safety tests to comply with IEC, UL, TUV, CSA, EN, and other electrical safety requirements.
-
Product
Capacitor Leakage Current/IR Meter
Chroma 11200
-
Chroma Systems Solutions, Inc.
The 11200 Capacitor Leakage Current / IR Meter is mainly used for electrolytic capacitor leakage current testing and aluminum-foil withstand voltage testing (EIAJ RC-2364A). The 11200 can also be used for active voltage checking or leakage current testing of absorber, Zener diode, and Neon lamp etc. With the standard RS232 interface, optional GPIB & Handler interfaces, high speed and stable measurement capabilities, the Chroma 11200 can be used for both component evaluation on the production line and for fundamental leakage current or IR testing for bench top applications.
-
Product
Multi-Channel Digital Power Meters
66203/66204
-
Chroma Systems Solutions, Inc.
Voltage Range :15/30/60/150/300/600 VrmsCurrent Range :0.005/0.02/0.05/0.2/0.5/2/5/20 ArmsFrequency Range : DC, 15Hz~10kHzEmbedded high speed DSP, 16 bits Analog/Digital convertersHalf rack size, 4 input modules design (66204)Support different wiring configuration power measurement (1P2W/1P3W/3P3W/3P4W)Support external shunt and CT for higher current measurement application5 mA minimum current range & 0.1mW power resolutionMeets ENERGY STAR / IEC 62301 /ErP measurement requirementsAccumulated energy methods for unstable power measurementUser-define criteria provides automatic PASS/FAIL indicationsDual current shunt design provides high accuracy over a wide current rangeTHD and user-specify order distortion measurementInrush current and energy measurementVoltage/ Current harmonics measurement up to 50 orders
-
Product
Sentry Hipot Tester AC/DC/IR
19070
-
Chroma Systems Solutions, Inc.
The Sentry 19070 Hipot Tester series provides 2 models to choose from. The Sentry 19071 for AC Hipot testing; and the Sentry 19073, which combines both AC and DC Hipot with insulation resistance (IR) measurements into a single compact unit.
-
Product
Regenerative Grid Simulator
61800
-
Chroma Systems Solutions, Inc.
Power rating: Up to 300kVA, single or three phase outputOutput Voltage: 0~330V L-N / 0~570V L-L0~400V L-N / 0~692V L-L opt. without using a transformerOutput Frequency: DC, 30Hz~100HzMaximum power delivered down to 200VAC L-NFull 4 quadrant, fully regenerative up to 100% of output current ratingSpecifically designed for PV inverter, Smart Grid and EV related test applicationsProgrammable slew rate settings for voltage and frequencyProgrammable voltage and current limitsTurn on, turn off phase angle controlLIST, PULSE, STEP mode functions for testing Power Line Disturbance (PLD) simulationVoltage dips, short interruption and voltage variation simulationHarmonics, inter-harmonics waveform synthesizerComprehensive measurement capability, including current harmonicsAnalog programmable interfacesRemote interface: GPIB, RS-232, USB and EthernetParallel output for higher power applications (three phase only)
-
Product
AC / DC Electronic Loads – Benchtop Testing to Automated Test Systems
-
Chroma Systems Solutions, Inc.
Chroma is the global leader in Electronic Load manufacturing. Chroma’s AC Electronic Loads are designed for testing uninterruptible power supplies(UPS), Off-Grid Inverters, AC sources, and other power devices such as switches, circuit breakers, fuses and connectors. Chroma’s DC Electronic Loads are used for power testing in all markets including automatic test systems, LED, power supply testing, battery testing, and fuel cell testing. Chroma loads can do it all including full current down to 0.4VDC, CZ mode, user defined waveforms, timing measurements, and 3 current ranges per load. Chroma’s electronic loads come standard with either USB or RS232 ports for control and can be configured for GPIB (IEEE-488) control as well.
-
Product
Partial Discharge Tester
19501-K
-
Chroma Systems Solutions, Inc.
The Chroma 19501-K Partial Discharge Tester is an instrument equipped with AC hipot test and partial discharge detection functions, providing 0.1kV~10kV of AC output, 0.01μA~ 300μA of leakage current, and 1pC~2000pC partial discharge detect ion range for measurement. Chroma 19501-K Partial Discharge Tester is compliant to the IEC60270-1 standard in particular the partial discharge testing requirements for high voltage.
-
Product
Milliohm Meter
16502
-
Chroma Systems Solutions, Inc.
Basic accuracy : 0.05%Pulsed test current output mode is used to reduce thermal EMFs affection on milliohm measurementDC test current output mode is used to fasten measurement speed for inductive DUTDry-circuit test current output mode (limited Max. 20mV) is used to measure such contact resistances where the maximum open-circuit voltage must be limited to 50mVTemperature correction (TC function) regardless of material or temperatureUseful temperature conversion function for motor/ coil evaluation4 channels R scan with balance check function for fan motor (combined with A165017 option)0.001mΩ~1.9999MΩ wide measurement range with 4½ digits resolutionStandard RS-232 interfaceOptional GPIB & Handler interfaceBin-sorting functionComparator and pass/fail alarming beeper functionLarge LCD display (240 x 64 dot-matrix)Friendly user interface
-
Product
Programmable AC Source
6500
-
Chroma Systems Solutions, Inc.
1200VA ~ 9KVADirect Digital Synthesis (DDS) waveform generationProgrammable voltage, current limit, frequency, phase, and distortion
-
Product
Programmable DC Power Supply
62000P
-
Chroma Systems Solutions, Inc.
Chroma’s Programmable DC Power Supplies 62000P Series offer many unique advantages for ATE integration and testing. Advantages include: constant power operating envelope, precision readback of output current and voltage, output trigger signals as well as the ability to create complex DC transients waveforms to test device behavior to spikes, drops, and other voltage deviations.
-
Product
Regenerative Battery Pack Test System
17040
-
Chroma Systems Solutions, Inc.
The 17040 Regenerative Battery Pack Test System is a high precision system specifically designed for secondary battery module and battery pack test. It has an energy regenerative function to greatly reduce power consumption during discharge, and ensure a stable power grid without generating harmonic pollution on other devices – even in dynamic charge and discharge conditions. It is capable of recycling the energy discharged by the battery pack test back to the grid reducing wasted energy that traditional equipment discharges in the form of heat.
-
Product
High Frequency LCR Meters up to 30MHz
11050
-
Chroma Systems Solutions, Inc.
The Chroma 11050 Series HF LCR Meter is a precision test instrument designed to accurately measure and evaluate passive components at high speeds. Its measurement capabilities cover the primary and secondary parameters required for testing the inductance, capacitance, resistance, quality factor and loss factor of passive components. The HF LCR Meter has a broad testing frequency range 75kHz~30MHz/1kHz~10 MHz/60Hz~5MHz suitable for analyzing component characteristics under different frequencies. Its 0.1% basic measurement accuracy provides stable and highly reliable results. A fast 7ms measurement speed effectively increases productivity when working in an automated environment.
-
Product
Programmable Benchtop DC Power Supply
62000L
-
Chroma Systems Solutions, Inc.
Provides high quality yet cost effective programmable benchtop DC power, designed to meet the stringent requirements of the next generation of power electronics.