Lisun Electronics Inc.
A leading manufacturer of lighting and electrical test instruments.
- 86(21)5108 3341
- SalesSH@Lisungroup.com
- 113-114, No.1 Building, Nanxiang Zhidi Industry Park
No. 1101, Huyi Road, Jiading District
Shanghai, 201802
China
-
Product
Digital Power Meter (AC & DC Model)
LS2012
-
• Measure Vrms, lrms, W, PF/Hz; • Measure AC, DC, AC+DC; • Automatic selecting, out of limit alarming, advance the work efficiency; • Voltage range: AC: 5-600V, DC: 1-600V. Current range: AC&DC: 0.005-20A with high measure accuracy. Auto range; • Accuracy: ± (0.4%reading + 0.1%range + 1digit).
-
Product
Near Field Moving Detector Goniophotometer
LSG-1900B
-
LSG-1900B Goniophotometer is near field Type C automatic goniophotometric instrument for luminous intensity distribution measurement. The LSG-1900B uses a constant temperature detector. It is for industrial laboratory photometric data measurements of small luminaires, such as down light, bulb light, etc.
-
Product
Spectroradiometer
-
Designed to have a capability of producing any visible spectral distribution, mimicking various light sources in the visible region by feedback control of the radiant power emitted by individual LEDs. This LED test system will be used as a transfer standard for photometric, colorimetric and radiometric applications.
-
Product
Aging and Optical Attenuation Tester
LS822
-
• Build-in DC Power Supply: Forward current preset: 0.1-800mA (special order) Range of forward voltage: 0.1-20.00V • Range of luminous intensity: 1mcd-3,000cd • Range of luminous flux: 1mlm-9,999,000lm(depends on the size of sphere) • Accuracy of photometer: class1; accuracy of electricity: class0.5 • Aging time: 9999Hours 59Munites 59Seconds • Tolerance of time: ±1S/10H • Record time: 16000times • Hold data automatically when the power is off and continue to work automatically when the power is turned on.
-
Product
Spring Impact Hammer IK Level Tester
IK01-06
-
The most of luminaires manufactory were request to do IK level test (Impact Protection), LISUN can supply the IK test instrument. IK ratings are defined as IKXX, where “XX” is a number from 00 to 10 indicating the degrees of protection provided by enclosures (including luminaires) against external mechanical impacts. The different IK ratings relate to the ability of an enclosure to resist impact energy levels measured in joules (J). IEC 62262 specifies how the enclosure must be mounted for testing, the atmospheric conditions required, the quantity and distribution of the test impacts and the impact hammer to be used for each level of IK rating. The IK test applicate on lighting luminaires test according to IEC60598 (GB7000) and IEC60068-2-75 (GB2423.55).
-
Product
Electronic Ballast Automatic Test Equipment
ATE-1
-
Test series connection, parallel connection and series/parallel connections of the electronic ballast (about 15 kinds of connections), available for various electronic ballast. • With a precise resistance box, tube is substituted for the resistance, can act as many as 6 tubes. Resistance value: 1-4095Ω adjustable. • Measure input parameters (vrms, irms, w, pf, harmonics, etc), output parameters (on-circuit voltage, lamp voltage, filament voltage, lamp current, lamp power, oscillatory frequency), can also test the ballast efficiency, abnormity protection, and power symmetry of partial rectifier effect and etc. • Program controlled AC power source to guarantee the smart choice of input voltage and the frequency. • Equipped with 17 inch LCD controlled machine, specially designed A/D combined with special CPU, has the two left and right testing interfaces to achieve stability of data and high- speed testing. • We can make the special-designed product for you and promise to upgrade the software for free.
-
Product
Programmable Withstanding Voltage & Insulation Test
LS9923
-
LS9923 programmable withstanding voltage & insulation test system is high-performance testing device special for AC&DC Withstanding Voltage and Insulation Resistance Test, It allows setting the output voltage. The warning value,testing time and some other parameters can be set in the screen.It with a variety of automatic test functions. The testing is quick and high accuracy which is not only applied in the production line but also in the develop research.
-
Product
Magnetic Field Generator
PFM61000-8A
-
PFM61000-8A Magnetic Field Generator is high reliability test equipment with stable performance, specially designed for electrical and electronic products for measuring immunity characteristics and requirements of normal frequency magnetic fields. It provides an accurate basis for the tested equipment in the immunity test of normal frequency magnetic field. The generator can imitate the magnetic field environments such as residential, commercial, industrial and mining enterprises, power plants, as well as middle and high substation. It fully meets IEC61000-4-8 and GB / T17626.8 standards.
-
Product
Standard Test Finger
SMT-1
-
It with Protection against electric shock device. It according to IEC60335, IEC60884, IEC61032, IEC60529, IEC60065, IEC60035, IEC60950, EN60529, EN60950, GB4706, GB7000, GB9706, UL507, VDE0470, etc.
-
Product
Multiplex Optical Maintenance Meter
LS280
-
LS280 is used to measure optical maintenance factor for high power LEDs, LED module, LED bulb or other LED luminaries. It is the important measuring equipment for performing the reliability of illuminants. • Freely set the time interval and time extent for automatic measurement • LCD Display, connect with PC via RS232 and English version software. • The test results can export Excel or PDF format and easy to compare. It can be saved by LS280 software or by USB directly. • The engineer can do LED life analysis based on the LS280 test results. • LS280 worked with High Power LED Aging Test (LS600), Multiplex LED Temperature Test (TMP-8/TMP-16) and High and Low Temperature & Humidity Chamber (GDJS-*B), it can do Flux VS Temperature VS Time, which is a perfect instrument system to meet LM-80 request.
-
Product
Electrodynamic Vibration Generator System
LVD-100KG
-
• Vibration table size: 500*500mm (Other size can be designed) • Vibration: 0~5mm (Adjustable range P-P). Vibration waveform: sine wave (half wave and full wave). Acceleration speed: 0~20g (Adjustable) • Maximum test load Capacity: 100kg • Accuracy: Frequency can be displayed to 0.01 Hz. Precision 0.1 Hz. • Sweep Frequency function (1~600Hz): (Upper frequency, Lower frequency, Time range) It can set real standard arbitrarily to sweep frequency back and forth • Programmable Function (1~600Hz): It can set each segment in 15 segments arbitrarily (frequency/amplitude/time/acceleration), and it can be recycled • Frequency doubling function (1~600Hz): 15 segments multiplied-increase: 1)Low to high frequency 2)High to low frequency 3)Low to high and then to low frequency, it can be recycled • Logarithmic function (1~600Hz), 3 modes of logarithm/can be recycled: 1)Lower to upper frequency 2)Upper to lower frequency 3)Lower to upper and then to lower frequency • Measuring instrument: To display amplitude, acceleration speed and the maximum acceleration speed.
-
Product
Fast Photo-Electric Tester
LS616S
-
The machine is made up of three main parts: measuring circuit of electric parameter, measuring circuit of photometric parameter and circuit of CPU system. Voltage and current signals are amplify and sent to high speed A/D transform, and the transform digital signals are sent to microprocessor, the input current signals of brightness detector are sent to A/D transform via I/V convert, and the transform digital signals are sent to microprocessor. Microprocessor processing the input photometric and electric data, it automatic switch between different range and calculate and display the data in the mean time.
-
Product
DIP LED Aging Tester
LS6100
-
Designed to measure the aging-life and color comparisons of 260pcs DIP LED. • 260 separate constant current supply • Aging functions: constant current, impact pulse, on-off mode • Range of forward voltage(VF): 5.0V • Range of forward current(IF): 1) constant current: 0-100.0mA 2) Impact pulse: 0-200.0mA • Range of impact pulse frequency: 10-9999Hz; Duty ratio: 1%-99% • Range of on-off circle: 0-9999H59M59S • Range of on-off times: 0-9999times • Range of aging time: 0-9999H59M59S
-
Product
Integrating Spheres
IS-*M
-
• Diameter: IS-0.3M (φ0.3m)、IS-0.5M (φ0.5m)、IS-1.0M (φ1.0m)、IS-1.5M (φ1.5m)、IS-1.75M (φ1.75m)、IS-2.0M (φ2.0m). Other sizes can be designed according to the customer’s request. • The painting of integrating spheres is according to CIE Pub.No.84 (1989) • Material: Pure barium soleplate (BaSO4) • BaSO4 coating: ρ(λ)≥0.96 (450nm~800nm) and ρ(λ) ≥0.92 (380nm~450nm) • Fine diffuse reflection: Reflectanceρ≈0.8 and accuracy of ρ (λ) <1.5% • Build-in lighting holder position: The vertical is for E40, E27 and so on. The horizontal is for T5/T8/T12 tubes. The side assistant opening is for lighting fixtures • Auxiliary lamp position has been built-in. Auxiliary lamp and Auxiliary lamp device are optional • Power cable and socket has been build-in, it is convenient to power the testing lamp • Two photo detector ports, one optical fiber port and temperature sensor hole are built-in • The traditional integrating sphere is assembled by several pieces, Lisun Group developed A Molding Technology to produce the integrating sphere. A molding integrating sphere will be more round and the test results will be more accurate than the traditional integrating sphere
-
Product
RF Conducted Immunity Test System
RFCI61000-4-6
-
RFCI61000-4-6 RF Conducted Immunity Test System is an automatic test system which is for the conduction sensitivity testing, it is fully meets IEC61000-4-6.2006, ISO11452-4, GB/T17626.6-2008 and GTB152B-CS114 etc standards. RFCI61000-4-6 internal source and broadband power amplifier can be generated 3 voltage test levels: 1v, 3v and 10v, and has the function of the real detect output level. It has two operation software which is calibration software and test software. When measuring, the signal is in 1 KHZ sine wave amplitude modulation system (80%) to simulate the actual harassment, and can through the coupling/decoupling network (CDN or electromagnetic clamp) to make the harassment signal coupled to the device.