Lisun Electronics Inc.
A leading manufacturer of lighting and electrical test instruments.
- 86(21)5108 3341
- SalesSH@lisungroup.com
- 113-114, No.1 Building, Nanxiang Zhidi Industry Park
No. 1101, Huyi Road
Shanghai, Jiading District 201803
China
Categories
-
product
Environmental Test Chamber
The chamber is produced by SUS304 Steel, the temperature keeping material is produced by Polyurethane hard foam and ultra-fine fibre glass, the doorframe heat insulated by Double high temperature aging silicone rubber door sealing strip.The temperature controller is used by Korean TEMI display in English/Chinese and German Siemens PLC, it can be communicated to PC via RS-232. The temperature accuracy is 0.1 and humidity is 0.1%R.HThe temperature sensor is platinum PT100 Ohms/MV resistor
-
product
Lamp Start, Run-up time and Flicker Test
LSRF-2
The (EU) NO 1194/2012rules
. Compared with which posted by theEuropean Commission Regulation (EC) NO 244/2009 Regulations dated 18th March, 2009, the new rules have complete mandatory and eco-design requirements. Start and Run-up time as the two indicators functional requirements in the industry has been more emphasis by manufacturers. -
product
LED Driver Automatic Test System
ATE-2
•This system includes 2 groups (left and right); the 2 groups can work in turn, so that to improve the work efficiency. For example, if the left is on working, then the right can make wire connection. •It can test 4 LED drivers input and output at one time. •The equipment can connect with electronic load and LED load, the two difference loads can be fast switch under the control of computer. •Enable to print out the series number and parameters of sub-quality products by working with a micro-printer, •Enable to achieve the bar-code record function by working with a bar-code scanner. •The test report can be saved as Excel file for consult, statistic and analysis purpose. •Good software interface to freely choose the difference parameters combination, so that to meet different demands. All the parameters can set limit, and with the quality analysis function.
-
product
Goniophotometer for Traffic Signal Lamps
LSG-1950S
LSG-1950S is a high automatic test system for luminous intensity distribution of luminaires and can be applied to quality evaluation and quality control for signal luminaires, luminaires for cars, motors, vessels and Retro-reflectors. LSG-1950S system is a goniophotometer which can measure all kinds of lamps and luminaires.• Rotations of test samples around both vertical axis (-90°~+90°) and horizontal axis (-35°~+35°) • Accuracy of angle: 0.1° • Resolution of angle: 0.01° • Photometer detector: CIE class A (standard class) accuracy • All software control, high intellectual faculties and simple operation
-
product
EMI Receiver System
EMI-9KC/EMI-9KB
EMI-9KB is an automatic EMI receiver system. It is a main test system for EMI (Electro Magnetic Interference) testing. The EMI-9KB is produced by the full closure structure and strong electro-conductibility material, which has high shielding effect. Due to the new technology for the EMI Test System, it solved the instrument self-EMI problem. The test results are according to the international format test report. The EMI Test System EMI-9KB fully meets CISPRl6-1, GB17743, FCC, EN55015 and EN55022.
-
product
AC and DC Power Supply
The DC Series Power Supplies are with high stability and high accuracy. The voltage and current can be adjustable and simple operation. They are suitable to supply DC Power for the standard lamp and the large power LED. Other voltage and current DC Power Supply can be designed according to customer's request.
-
product
Pocket Chroma Meter
CHROMA-2
CHROMA-2 Pocket Chroma Meter is developed based on TOSHIBA TCD1304DG linear array CCD detector. It makes traditional laboratory instrument available for the production on-line quality acceptance, thus greatly improved the efficiency of fluorescent lamp, CFL, LED.
-
product
Integrating Sphere With Holder Base
IS-*MA
1. The hold base can bear max 20kg, it can expanding to test all lamps such as E27/E40, all tubes such as T5/T8/T12, and all kinds of luminaries2. The hold base can be installed in the ceiling or down, it can be adjusted the height3. Hold base has four power cables connect to the outside Power Supply and max is 5KW4. The holder base is detachable. For some kinds of light sources you may need to change the position of the holder base.5. Diameter: IS-0.3M (0.3m), IS-0.5M (0.5m), IS-1.0MA (1.0m), IS-1.5MA (1.5m), IS-1.75MA (1.75m), IS-2.0MA (2.0m). Other sizes can be designed according to the customer’s request.6. The painting of integrating spheres is according to CIE Pub. No.84 (1989)
-
product
Photometer
PH2000
The digital photometer is used with an photo detector and an integrating sphere for luminous flux lumen measurement.
-
product
Three Loop Antenna
VVLA-30M
The three loop antenna VVLA-30M is a standard measurement antenna according to CISPR15-2005/GB17743-2007 standard
, it can work with LISUN EMI-9KA / EMI- 9KB EMI Receiver System for EUT magnetic field radiation measurement between X, Y and Z planes. The antenna measurement is accurate, switch conveniently and it can completely replace imported products. -
product
DC Power Source for Standard Lamp
DC502
DC502 is CONSTANT CURRENT DC POWER SUPPLY for standard lamp. Function and technical indexes are as follows: • output voltage 4 grades: 6V/12V/24V/50V • output current: DC 0~2.5A (adjustable) • Output current drift at full scale: ±0.05% reading value/10 mins • Monitor range of ampere meter: 0.0000A ~1.9500A, 1.950 A ~2.500A • Accuracy of ampere meter: ± (0.08% reading value + 0.02% full scale) • Max output power: 80W • Continuous working time: 8 hours • Work environment: Temperature 0℃ -25℃, humidity ≤ 85%R.H, supply source: AC220 ±10%, 50/60HZ • Holding conditions: -20~50℃ humidity < 75%R.H • Outside dimension (W×H×D): 333mm×114mm×307mm • Weight: about 8kg • Power: about 1000VA
-
product
Automatic Safety Test System
LS9955/56
The LS9955/LS9956 Automatic Safety Test System is according to GB4706.1, IEC/EN60335-1, UL60335, GB7000, IEC60598, GB4943, IEC60950 and GB9706.1. It used for luminaries, home application and motor tools safety test in production line or Lab R&D.
-
product
Multifunctional Immunity Test System For Automotive Electronics
EMS-ISO7637
EMS-ISO7637 automotive multifunctional immunity test system meet newest ISO7637-2 requirement of
. This standard was issued by international organization for standardization, and this system included all of ISO-7637 required test waveform and meet most of automotive manufacturer’s requirement for automotive electronic immunity test. -
product
Spectroradiometer
Spectroradiometer is usually used with a integrating sphere to measure the photometric and colorimetric parameters of all kinds of lamps. Relative spectral power distribution P(λ), chromaticity coordinate (x,y), (u,v), correlated color temperature Tc, color rendering index Ra, dominant wavelength, peak wavelength, spectral bandwidth, color purity, color ratio, SDCM, luminous flux, etc.
-
product
LMS-7000CCD Spectroradiometer
LMS-7000
LMS-7000 CCD Spectroradiometer is applied with TOSHIBA TCD1304DG linear array CCD detector, measurement speed is very quick and cost-saving.• The following wavelength range is with 0.8nm FWHM: • Integrating time is 1ms to 60s • CCD Detector is 3648pix which size is 8μm×200mμm • SNR (Signal to Noise Ratio) is 1000: 1 (Full range). A/D is 16bit • Communicate with PC by USB2.0. The software has a rich re-develop platform which can be run in WinXP and Win7. • Optical port is SMA905