Lisun Electronics Inc.
Lisun Electronics Inc was found by Lisun Group in 2003. We have sales & service offices in Shanghai, Russia, India and Korea. In 2012, we built a high level products show room & lab center in Shanghai. Lisun Group has set up a new manufactory in China to research and develop the world high-technology CFL & LED Test Instruments. Its quality system has been strictly certified by ISO9001:2008. The Lisun Group products have been authenticated by the third party lab and were awarded by CE certificate. As a CIE Supportive Member, all of the test instruments produced by Lisun Group are designed according to CIE Standards.
- 86(21)5108 3341
- SalesSH@lisungroup.com
- 113-114, No.1 Building, Nanxiang Zhidi Industry Park
No. 1101, Huyi Road
Shanghai, Jiading District 201803
China
-
product
Digital Power Meter (Harmonic Analyzer Model)
LS2010
• Measure Vrms, lrms, W, PF, Hz; • Harmonic distortion analysis for voltage & current, display total harmonic and 0-50 times; • Component harmonic, selectable for absolutely or relatively harmonic display; • Voltage range: 10.0-600.0V, Current range: 0.010-20.00A, Auto range; • Accuracy: ± (0.4%reading + 0.1%range + 1digit); • Simultaneously display Vrms, lrms, W, PF value on 4 windows, suitable for production line; • Can test every kinds of curve; Print both data & curve; • Communication port for PC, run under WinXP or Win7.
-
product
Surge Generator
SG61000-5
Automatic lightning surge generator (or Lightning surge immunity) SG61000-5 is used to assess the power cord and connect the internal switch stood in line to connect the internal switch to provide a common basis for switching the natural world and lightning caused by the high-energy transient interference performance. Performance fully meets the IEC 61000-4-5, EN61000-4-5 and GB/T17626.5 standards.
-
product
Integrating Sphere
The standard test temperature is 25, but high power lamps such as HID lamps and LED outdoor luminaires will produce a lot of heat during the test, thus the temperature inside the integrating sphere can not meet the requirements of IEC standards. Lisun Group designed the Constant Temperatured Integrating Sphere which allows the lamp was tested in a constant air temperature.
-
product
High and Low Temperature & Low Pressure Chamber
LAP-100
It is according to GB10590 / GB15091 low temperature / low pressure test chamber requirements; GB11159 low pressure test chamber requirements; GB / T2423. 25-1992 low temperature / low pressure integrated chamber requirement; GB / T2423. 26-1992 High temperature / low pressure integrated chamber requirement; GJB150. 2-86 low temperature / low pressure test etc standards. It’s used to test the In aviation, aerospace, information, electronics and other fields, to determine the instrumentation, Electrical products, materials, components, equipment etc.
-
product
Input Characteristic Analyzer of Electronic Ballast
UI2001
• 4 display windows for V (600V), A (2A), W, PF/Hz • THD, 0 to 39th harmonic components • Accuracy: ± (0.4% reading + 0.1% range + 1 digit) • Data and curves printable. All the data and curves can be displayed after being connected with PC
-
product
High Power LED Aging Tester
LS600
• The standard LS600 has 1 Group which has 8 channels. That means LS600 can test 8 LEDs separately at one time. (Optional: it expand to 8 Groups which can test 64 LEDs separately at one time) • Aging Functions: Constant Current, Impact Pulse, On/Off Mode • Output current: 1~1000mA (Special Order Available) • Output voltage: 5V(Special Order Available) • Output frequency: 1~3000Hz, Duty Ratio: 1%-99% • Range of on-off circle: 0~9999h/59m/59s
-
product
Integrating Sphere with Side Assistant Opening
IS-*MA**P/IS-*MA**C
According to IES LM-79 Clause 9.1.2, it request the 4π geometry configuration and 2π geometry Integrating Sphere for the LED Testing. Lisun Group developed the integrating sphere with side assistant Opening in A Molding Technology to meet the requirements.• Painting material of integrating spheres is according to CIE Pub.No.84 (1989) • The painting material is BaSO4 coating: ρ (λ) ≥0.96 (450nm~800nm) and ρ (λ) ≥0.92 (380nm~450nm) • Fine diffuse reflection: Reflectance ρ≈0.8 and accuracy of ρ (λ) <1.5% • Build-in all functional lamp testing jigs: the vertical is for E40/E27, the horizontal is for T5/T8/T12 tubes and the Testing Holder Base for LED street luminiares. All of the testing jigs can allow the lamp be tested up and down in the sphere. • Power Cable, Power Terminal and Auxiliary lamp position has been built-in (Auxiliary lamp is option). • Two photo detector ports, one optical fiber port and temperature sensor hole are built-in • Ordering Code: IS-1.5MA55P or IS-1.5MA55C (Φ1.5m, IS-1.5MA55P means square side opening is 0.5×0.5m, IS-1.5MA55C means cycle side opening diameter is 0.5m). IS-1.75MA66P or IS-1.75M66C (Φ1.75m and side opening is 0.6m). IS-2.0MA77P or IS-2.0MA77C (Φ2.0m and side opening is 0.7m). • Other size such as diameter 2.5m, 3.0m can be special order according to customer’s request
-
product
Standard Test Finger
SMT-1
It with Protection against electric shock device. It according to IEC60335, IEC60884, IEC61032, IEC60529, IEC60065, IEC60035, IEC60950, EN60529, EN60950, GB4706, GB7000, GB9706, UL507, VDE0470, etc.
-
product
Current Transformer Tester
HTCT-300
Full-featured, can not only satisfy various CT (eg: protection, measurement and TP category) but also PT type electromagnetic unit for its excitation characteristics (ie voltage current characteristics), ratio, polarity, secondary winding resistance, secondary load, ratio deviation, angle deviation and other test requirements.
-
product
LM-79 Moving Detector Goniophotometer
LSG-5000
Moving Detector Goniophotometer completely meets LM-79 Clause 9.3.1 and EN13032-1 clause 6.1.1.3 goniophotometer type 4 requirements. The LSG-5000 is an automatic light distribution intensity 3D curve testing system for measuring light. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.
-
product
Online OK Tester for Electronic Ballast and CFL
WT-1
• Test 6 pieces at one time, suitable for mass testing in assembly line. • Measure parameter: Vrms, lrms, W, PF. • Freely set upper and lower limit for lrms, W, PF, alarm when value out of limits. • Freely set test duration in range: 0-99.9s, tested data automatically locked. • Test range: 1) Vrms: 10.0-300.0V 2) lrms: 5-999mA 3) W: 0.1-300.0W 4) PF: 0.0001-1.000 • Accuracy: 0.5% • Digital display on 6 windows is easy to read • Print port and communication port available (optional)
-
product
Thermal Sensitive Parameter Selector
UI9600
Parameter measured under normal temperature:1) β (0-99)2) Switching time T (0.01μs-99.9μs), including Tr, Ts, Tf3) VCES (0-2V), VBE (0-2V)4) Leakage current ICEO (0.01μA-99.9mA)5) Withstand voltage BVCEO (50V-650V)• Parameter measured under high temperature: VBE, β, ICEO
-
product
LED Thermal and Electrical Performance Analyzer
T5
Thermal parameter is the key index to evaluate the performance of LED. It’s very important to measure thermal characteristics of high power LED for high reliability LED applications. It will have effect on the optical parameters, electricity parameters and lifetime of LED. Therefore, design and control of the thermal dissipation is the most important thing for the manufacturers and users.
-
product
Goniophotometer
A device used for measurement of the light emitted from an object at different angles