Lisun Electronics Inc.
A leading manufacturer of lighting and electrical test instruments.
- 86(21)5108 3341
- SalesSH@lisungroup.com
- 113-114, No.1 Building, Nanxiang Zhidi Industry Park
No. 1101, Huyi Road
Shanghai, Jiading District 201803
China
-
Product
Lamp Cap Temperature Rise Test System
TMP-L
-
TMP-L is according to IEC60360-1998 and GB2512-2001 (Standard method of measurement of lamp cap temperature rise). It is used to test the working and environmental temperature as well as temperature-rise of the burner and lamp. It meets the requirement of IEC and GB Standards.
-
Product
PWM Type AC Power Supply
LSP-5KVA
-
• Circuit Type: (IGBT) MPWM Pulse Duration Modulation • Input: 1 Phase 220V±10%, 50Hz/60Hz±5% • Output Voltage: HIGH/LOW Adjustable 1)1 Phase Voltage Range: (HIGH)0~300V, (LOW)0~150V 2) Nominal Voltage: +10%~+25%, -10%~-30% • Output Frequency: 50Hz, 60Hz, adjustable between 45 and 70 Hz, 400Hz • Load Voltage Stabilization Rate: ≦0.5% • Frequency Stabilization Rate: 0. 1% (Fix Point 50Hz, 60Hz and 400Hz) • Wave Distortion Rate: ≦2% (Resistor Load); Efficiency: ≧85% • Output Instruments: Frequency Indicator, 4-digits RMS digital frequency indicator, resolution is 0.1Hz Voltage Meter, 4-digits RMS digital voltage meter, resolution 0.1V Ampere Meter, 4-digist RMS digital ampere meter, resolution 1Ma Power Indicator, 4-digits RMS digital power indicator, resolution 1W Power Factor Meter Resolution 0.001 • Protective Devices: Over load, short circuit, over voltage, over current, over temperature protective and alarm devices • Operating Environment: Temperature 0~40℃ Relative Humidity 0~90%
-
Product
Spectroradiometer
-
Designed to have a capability of producing any visible spectral distribution, mimicking various light sources in the visible region by feedback control of the radiant power emitted by individual LEDs. This LED test system will be used as a transfer standard for photometric, colorimetric and radiometric applications.
-
Product
Rotation Luminaire Goniophotometer
LSG-1800
-
LSG-1800/LSG-1700 Goniophotometer is high precision automatic goniophotometric instrument for luminous intensity distribution measurements with facility for turning the light source. The LSG-1800 is an update version for LSG-1700, the LSG-1800 use a high accuracy Motor and precision angle coder which keeps high test accuracy. It is for industrial laboratory measurements the photometric data of luminaries such as LED luminaries, HID lamps, fluorescent lamps and so on.
-
Product
Impulse Magnetic Field Immunity Tester
IMF61000-9
-
IMF61000-9 impulse magnetic field immunity tester is high performance test instrument which special designed for to do impulse magnetic field immunity test and fully meet IEC61000-4-9, EN61000-4-9 and GB/T17626.9 standards, also it come with high intelligent, high stable performance and easy operation characteristics.
-
Product
High Accuracy Spectrophotocolorimeter
LMS-3000
-
• Measure and display the relative spectral power distribution (UV-VIS-NIR) P(λ), chromaticity coordinate, correlated color temperature, rending index, color difference, peak wavelength, luminous flux, luminous flux efficiency and photometry parameters of light source and light material under the control of general PC. • Automatically adjust high-voltage, it not only shortens the measurement time, but also reduces the wear and tear of the instrument • Simultaneously measure the temperature in both environment and integrating sphere to make the data more visually and reliably • Figure of chroma and color difference in test report can be exchanged freely • Color display and print. The relative spectral power distribution (UV-VIS-NIR) P(λ), reports both in English. RS-232-C interface, compatible with all kinds of computer • LSP-500 AC Power source PC RS-232-C interface. compatible with all kinds of computer • Range of wavelength: 380nm~780nm(Special:200nm~780nm) • Accuracy of wavelength: ±0.2nm • Repeatability of wavelength: ±0.1nm • Accuracy of chromaticity coordinate: ±0.0003(under standard illuminate A) • Spectrum sample interval: 5nm(Special order:1nm) • Luminosity linearity: 0.3% • Accuracy of luminosity: 1 class • Correlated color temperature measure range: 1500K~25000K • Accuracy of CCT: ±0.3%(under standard illuminate A) • Accuracy of rending index: ±(0.3%rd±0.3) • Environment temperature measure range: -10℃~80℃ • Temperature measure range(In sphere): -10℃~100℃
-
Product
LED Luminous Intensity Distribution Tester
LS860
-
LS860 Luminous Intensity Distribution Tester is a precise electronic instrument for measuring LED luminous intensity. It’s strictly designed according to LED standard requirements of CIE 127-1997 A or B Condition.
-
Product
LM-79 Moving Detector Goniophotometer
LSG-5000
-
Moving Detector Goniophotometer completely meets LM-79 Clause 9.3.1 and EN13032-1 clause 6.1.1.3 goniophotometer type 4 requirements. The LSG-5000 is an automatic light distribution intensity 3D curve testing system for measuring light. The measuring distance is from 5m to 30m. It can measure all types of lighting sources, LED or HID luminaires such as indoor and outdoor luminaires, roadway luminaires, street lamps, flood lights and other kinds of luminaires.
-
Product
Surge Generator
SG61000-5
-
Automatic lightning surge generator (or Lightning surge immunity) SG61000-5 is used to assess the power cord and connect the internal switch stood in line to connect the internal switch to provide a common basis for switching the natural world and lightning caused by the high-energy transient interference performance. Performance fully meets the IEC 61000-4-5, EN61000-4-5 and GB/T17626.5 standards.
-
Product
Car Accessories Material Burning Tester
ZRS-4H
-
• Test Gas Source: Gas or Liquefied Petroleum Gas (Suggestion: Use good quality gas if possible) • Burner inner diameter: ¢9.5±0.5mm, about 100mm long with air adjusting hole • Height of flame: Can be adjusted from 20 mm to 100 mm according to the standard requirement • Applying time of flame: Burning time can be adjusted from 0 to 99 minutes 99 seconds • Test process: Automatic control • Inner volume: 0.05m³ • Material: Stainless steel or iron plate spray • Power: AC 220V; 50Hz/5A
-
Product
Magnetic Shielding Cabinet for EMI Testing
SDR-2000B
-
Cabinet Shell 2mm galvanized cold-rolled steel sheetCabinet Door 0.9*1.7m(L*W) 0.6*0.6mCabinet Window 0.3*0.3*0.025m(L*W*T) with 4mm hole N/APower Supply Filter 30A/220V 30A/220VInternet Line Filter RJ-45 N/ACabinet Inside Decoration PVC ceiling, PVC plastic steel wall, 10mm wooden + 2mm galvanized steel sheet floorCabinet Inside Size 2*1.2*1.8m 0.8*0.8*0.8mAfter Packing Size 2.2*2.3*2.3m 1*1.1*1.2mAfter Packing Weight 800kg 200kgWorking With EMI-9KA/EMI-9KB EMI-9KA/EMI-9KB, PC, Testing load, and operator inside Testing load is inside to connect with EMI-9KA/EMI-9KB via BNC
-
Product
IK Level Tester
IK07-10
-
IK ratings are defined as IKXX, where “XX” is a number from 00 to 10 indicating the degrees of protection provided by enclosures (including luminaires) against external mechanical impacts. The different IK ratings relate to the ability of an enclosure to resist impact energy levels measured in joules (J). IEC 62262 specifies how the enclosure must be mounted for testing, the atmospheric conditions required, the quantity and distribution of the test impacts and the impact hammer to be used for each level of IK rating. The IK test applicate on lighting luminaires test according to IEC60598 (GB7000) and IEC60068-2-75 (GB2423.55).
-
Product
Power Cord Bending Tester
SW-6
-
SW-6 Power cord bending tester is fully designed according to the IEC standard, and can also be costumer-sized depends on the samples’ type and the costumer’s requirement. Specifications: • Power supply:AC220V 50/60HZ 12KVA • Control mode: PLC with touch screen and Servo motor. • Test Speed: 10~60times/min (Adjustable) • Test Degree: 0~540° (Adjustable) • Counter: 0~999999 (Can be pre-set) • Weight: 5N,10N,20N. 2Sets. (6Position type will have 6 Sets) • Position: 2/6 • Load Current: 0~20A (Adjustable) • Angle plate: Can check the test situation • Sample fixture: Can be costumer-sized. • Can do power line bending test (The User need prepare sample and power supply ), Can record the number of the sample’s work with load.
-
Product
Programmable AC Power Source
LSP-500VAC
-
• Applied with the AC-DC-AC inverter technology and digital waveform synthesis & waveform feedback technology, low distortion power; • Applied with entire cycle high-precision measurement technology and high-speed sampling technologies, panel of instrument will directly and accurately displays the power output of the voltage, frequency, current, active power and power factor to achieve the integration of the source table; • Applied with SCM control and measurement technology, high intelligence; • Applied with zero output impedance technology, the output equivalent impedance is almost zero and further improve the stability of power supply; • Applied with isolated floating output technology, the power output and input have good isolation, floating output, conducive to make sure power itself safety and operator’s safety; • Perfect voltage, current anomalies and overheating protection, improve the reliability of power supply; • Applied with power limiting technology to avoid strong interference on the power grid and other electrical equipment, while facilitating reliable operation of the power supply itself; • The input voltage can be option via a toggle switch of panel mains 110V/220V; • The initial phase and end phase of the output voltage waveform can be set {0°-359° (±1°)}; • Measurement process can be programmed to control (1 to 50 memory groups, 1 to 9 steps for each memory group);
-
Product
Magnetic Material Analyzer
UI9730
-
Parameters to be measured (absolute value): Measure hypo-class U, Iout, Hz, Hc, Br, Bm, Hm, Br /Bm, μm, magnetic core loss, B-H curve, U curve and I curve• Output capacity of the high frequency power: Uout: 1~300V, Iout: 0.05~5A, Pout: 300VA, frequency: 10~300kHz















