Optical Radiation Safety Test
EN62471-C
IEC62471-2006(CIE S009) Photobiological Safety of Lamps and Lamp System and IEC TR62471-2(2009) Guidance on Manufacturing Requirements Relating to Non-laser Optical Radiation Safety have be published addressing hazard to human (mostly eye and skin), and are completely suitable to assess the optical radiation safety of non-laser sources, such as LED products, UV radiation in general lighting products and etc.
-
product
Ball Pressure Test Device
ZBP-T
Made up by the related item according to IEC60695, IEC884-1, GB/T5169.21-2006, GB4706.1-2005, GB2099.1-2008, etc. • R = 2.5mm Pressure: 20N • Base with thermocouple hole • Material: 304 stainless steel
-
product
CCD Spectroradiometer Integrating Sphere Compact System
LPCE-3
LPCE-3 is a CCD Spectroradiometer Integrating Sphere Compact System for LED Testing. It is suitable for photometric and colorimetric measurement of luminaries such as LEDs, LED luminaires, Energy-saving lamps, Fluorescent lamps, HID lamps (high voltage sodium lamps and high voltage mercury lamps) and CCFL. The measured data meets the requirements of CIE, EN and LM-79 clause 9.1 for the measurement of photometry and colorimetry.
-
product
High and Low Temperature Thermal Shock Chamber
HLST-500D
The specimen is placed in test chamber specimen which cannot be placed in high temperature chamber or low temperature chamber. High temperature chamber pre-heats the air and low temperature air chamber pre-cools the air. When doing the test of temperature changing from high to low, the low temperature chamber will blow the pre-cooled air to the test chamber. Then, the air in test chamber will reach your target temperature in several minutes (“recover time”). When doing the test of temperature changing from low to high, the high temperature chamber will blow the pre-heated air to the test chamber. Then the air in test chamber will reach your target temperature within the recover time.
-
product
Electronic Ballast Production Line Tester
UI2000-OK
• Eight windows for displaying input characteristics, output characteristics, convenient for comparison and analysis. • Frequency response for testing input current up to 1 MHz, suitable for precise testing of various kind of electronic ballast. • High speed testing, finish testing input and output characteristics within 1 minute. • Portable with built-in chip micro-processor, particular suitable for development and spot production. • Parameters, waves and curves of input, output and startup can be printed. • Communicating with PC, special software provided and both Chinese version and English version available. Run in WINDOWS3.2, WINDOW95 or WINDOWS98, nice interface between people and computer, easy to operate.
-
product
HID Ballast Tester
WT2000-HID
• Input Parameters Measurement: 1) Test voltage, current, power, power factor, power line frequency, total harmonic and 0~50 harmonic 2) Range of voltage and current basic wave frequency: 45Hz~65Hz 3) Range of narrow frequency: 45Hz~5kHz 4) Range of wide frequency: 45Hz~1MHz
-
product
Near Field Moving Detector Goniophotometer
LSG-1900B
LSG-1900B Goniophotometer is near field Type C automatic goniophotometric instrument for luminous intensity distribution measurement. The LSG-1900B uses a constant temperature detector. It is for industrial laboratory photometric data measurements of small luminaires, such as down light, bulb light, etc.
-
product
PWM Type AC Power Supply
LSP-5KVA
• Circuit Type: (IGBT) MPWM Pulse Duration Modulation • Input: 1 Phase 220V±10%, 50Hz/60Hz±5% • Output Voltage: HIGH/LOW Adjustable 1)1 Phase Voltage Range: (HIGH)0~300V, (LOW)0~150V 2) Nominal Voltage: +10%~+25%, -10%~-30% • Output Frequency: 50Hz, 60Hz, adjustable between 45 and 70 Hz, 400Hz • Load Voltage Stabilization Rate: ≦0.5% • Frequency Stabilization Rate: 0. 1% (Fix Point 50Hz, 60Hz and 400Hz) • Wave Distortion Rate: ≦2% (Resistor Load); Efficiency: ≧85% • Output Instruments: Frequency Indicator, 4-digits RMS digital frequency indicator, resolution is 0.1Hz Voltage Meter, 4-digits RMS digital voltage meter, resolution 0.1V Ampere Meter, 4-digist RMS digital ampere meter, resolution 1Ma Power Indicator, 4-digits RMS digital power indicator, resolution 1W Power Factor Meter Resolution 0.001 • Protective Devices: Over load, short circuit, over voltage, over current, over temperature protective and alarm devices • Operating Environment: Temperature 0~40℃ Relative Humidity 0~90%
-
product
Voltage Dips and Interruptions Generator
CSS61000-11
The voltage dip and interruptions generator is specially designed according to the characteristics and requirements of EMS measurement under a sudden reduction or interruption of the voltage at a point, CSS61000-11/ CSS61000-11T used a big LCD in both English and Chinese operating interface. They have more fine performance such as high reliability, convenient operation, and full meet the standard requirements of IEC 61000-4-11, EN 61000-4-11 and GB/T17626.11
-
product
Digital Oscilloscope
JC2202TA
The JC Series Digital Oscilloscope was designed and produced by high accuracy electronic components and modules. The test accuracy is world high class. It is used in all kinds of electronic products testing.
-
product
Aging and Optical Attenuation Tester
LS822
• Build-in DC Power Supply: Forward current preset: 0.1-800mA (special order) Range of forward voltage: 0.1-20.00V • Range of luminous intensity: 1mcd-3,000cd • Range of luminous flux: 1mlm-9,999,000lm(depends on the size of sphere) • Accuracy of photometer: class1; accuracy of electricity: class0.5 • Aging time: 9999Hours 59Munites 59Seconds • Tolerance of time: ±1S/10H • Record time: 16000times • Hold data automatically when the power is off and continue to work automatically when the power is turned on.
-
product
Multiplex Optical Maintenance Meter
LS280
LS280 is used to measure optical maintenance factor for high power LEDs, LED module, LED bulb or other LED luminaries. It is the important measuring equipment for performing the reliability of illuminants. • Freely set the time interval and time extent for automatic measurement • LCD Display, connect with PC via RS232 and English version software. • The test results can export Excel or PDF format and easy to compare. It can be saved by LS280 software or by USB directly. • The engineer can do LED life analysis based on the LS280 test results. • LS280 worked with High Power LED Aging Test (LS600), Multiplex LED Temperature Test (TMP-8/TMP-16) and High and Low Temperature & Humidity Chamber (GDJS-*B), it can do Flux VS Temperature VS Time, which is a perfect instrument system to meet LM-80 request.
-
product
Electronic Ballast Analyzer
WT3000
• It has 8 windows to display each parameter of input and output characteristics • Frequency response for testing input current up to 1MHz, suitable for precise testing of various kind of electronic ballast • WT3000 has expanding analysis for envelope wave. • Symmetry analysis for envelope wave’s crest factor of lamp current • Sampling at ultra-high speed, dynamic analysis single frequency curve, highest sampling frequency is up to 10MHz • Portable with built-in chip micro-processor, particular suitable for development and spot production • RS-232C standard interface can be connected to PC, English version software can run in WinXP or Win7
-
product
Multiway Life Tester
CH316
Measure 16 samples at the same time, evaluate and record the life of each sample. Very flexible: Samples can be added and changed at anytime. The life of each sample is readable at anytime. The switch ON/OFF time is adjustable (Test period is min 1s). Automatically remember the test result when the power is off, and resume the old measurement when power is on. Sound and light alarm when the products were failed.
-
product
High Power LED Aging Tester
LS600
• The standard LS600 has 1 Group which has 8 channels. That means LS600 can test 8 LEDs separately at one time. (Optional: it expand to 8 Groups which can test 64 LEDs separately at one time) • Aging Functions: Constant Current, Impact Pulse, On/Off Mode • Output current: 1~1000mA (Special Order Available) • Output voltage: 5V(Special Order Available) • Output frequency: 1~3000Hz, Duty Ratio: 1%-99% • Range of on-off circle: 0~9999h/59m/59s