Filter Results By:
Products
Applications
Manufacturers
Temperature Calibration Baths
-
product
Calibration Baths
Fluke Calibration temperature baths provide optimal temperature environments for “secondary” or “comparison” temperature calibrations. They offer unsurpassed stability and uniformity, a large working volume, and flexibility for performing thermometer calibration on calibrating a variety of temperature sensors. A world-class temperature controller and 30+ years of experience make these the choice of National Metrology Institutes and calibration laboratories worldwide. Fluke Calibration temperature baths include: compact temperature baths; deep-well temperature baths; standard calibration baths; resistor maintenance baths; ice-point baths; bath / temperature controllers.
-
product
4-in-1 OSLT Mechanical Calibration Kit, DC To 18 GHz, Type-N (m) 50 Ohm
85518A
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
product
REM-11120, 4-Channel Thermocouple, 1-Channel Voltage, Temperature Input Module for Remote I/O
784750-01
4-Channel Thermocouple, 1-Channel Voltage, Temperature Input Module for Remote I/O - The REM‑11120 is a temperature input module for remote I/O. Remote I/O systems are low-cost, modular systems for simple machine control and measurements. A remote I/O system consists of an EtherCAT bus coupler and individual modules mounted on a DIN rail. You control the REM‑11120 from a real-time controller such as a CompactRIO Controller or an Industrial Controller. You can use remote I/O hardware to add low-cost I/O for simple tasks while your controller handles advanced tasks such as image processing, motion control, and high-speed or specialty measurements. The REM‑11120 also has an adjustable filter time for improved measurement quality and optional external cold junction compensation (CJC) or PT100 resistance temperature detector (RTD) measurements.
-
product
NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module
785185-02
16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
product
4-in-1 OSLT Mechanical Calibration Kit, DC To 9 GHz
85515A
The 85515A 4-in-1 mechanical calibration module combines an open, short, load, and through in a compact unit. The product is small, easy to handle, and light weight. The through allows users to easily calibrate non-insertable devices, such as a cable or filter with female-female connectors. During the “thru” part of the calibration, the 85515A through can be used.
-
product
4-In-1 OSLT Mechanical Calibration Kit, DC To 18 GHz, Type-N (f) 50 Ohm
85519A
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
product
Calibration Cable, 78-pin D-type, Thermocouple Simulator Modules
40-975-078-1m
This cable assembly is specifically designed to connect to the 78-Pin D-Type port on the front panel of Pickering Interfaces Thermocouple Simulator Modules 41-760 and 41-761 enabling calibration via an external DMM.
-
product
NI-9213, 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module
785185-01
16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module - The NI‑9213 is a high-density thermocouple input module that is designed for higher channel count systems. With this module, you can add thermocouples to mixed-signal test systems without taking up too many slots. The NI‑9213 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9213 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
783864-02
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
product
sbRIO-9211, Non-Enclosed, 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module
780877-01
Non-Enclosed, 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module - The sbRIO‑9211 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The sbRIO‑9211 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.
-
product
Portable Calibration Baths
6109A / 7109A
The Fluke Calibration 6109A and 7109A Portable Calibration Baths are liquid baths that let process industry professionals calibrate four times more sanitary sensors per batch in less time and with twice the accuracy of other portable baths in this class. Larger than micro baths, up to four tri-clamp sanitary sensors fit easily into these baths for calibration at ± 0.1 °C temperature display accuracy. Throughput is even higher for sanitary RTDs with small or no flanges. Two bath models cover a wide temperature range: 35 °C to 250 °C for the 6109A and -25 °C to 140 °C for the 7109A. Each model offers a “-P” version that includes process electronics for connecting an external reference probe. Professionals working in clean process industries, including facilities managers, production engineers and calibration technicians, prefer these baths for a variety of reasons.
-
product
NI-9212, 8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module
782975-01
8-Channel, 95 S/s/ch Simultaneous, ±78 mV C Series Temperature Input Module - The NI‑9212 offers channel‑to‑channel, isolated thermocouple input channels. The NI‑9212 channel‑to‑channel isolation protects channels from continuous voltages up to 250 Vrms and transient (withstand) voltages up to 1500 Vrms. You can use the NI‑9212 in a variety of applications that are not conducive for bank-isolated channels such as white goods testing, in-vehicle data logging, battery stack testing, as well as in various other noisy industrial environments.
-
product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
783864-01
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
783863-01
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
product
Temperature Calibration
Trescal provides full Temperature Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Temperature Calibration services can be delivered at your site or at our lab. Accreditations for our temperature calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
product
Calibration Kit YAV90MMU
YAVMMUCK
The Calibration Kit includes the tools for YAV90MMU test and calibration. As the YAV90MMU is the core of the YAVPack Bundle (YPB), this calibration kit is also an option for the YPBs.
-
product
Temperature Baths and Circulators
Accommodates up to 6 temperature measurement devices 2 to 8 mm in diameter; includes bath lid with sleeves for two each 3, 4 and 6 mm diameter openings
-
product
Temperature Controlled Water Bath
WB
Digital temperature controllerStainless steel tank with structural steel baseTiming circuit refreshes water for a full two minutes each hour preventing buildup of weak acid and stale waterWater level adjustable by standpipe changeOverhead wire tray with openings for optional test leadsHolds 15 SLI storage batteries (BCI group 24)
-
product
Temperature Calibration Equipment
We offer wide line of temperature calibration equipment for calibration of contact type sensors (Baths/furnaces) and non contact type sensors (Black Bodies), available in temperature range -80°C to 1700°C.
-
product
Temperature Calibrators
Fluke Temperature Calibrators simulate process sensors for testing temperature instrumentation. Specifically designed for the field, these lightweight compact tools are EMI tolerant, dust and splash resistant and offer an easy to use single push button interface. When paired with a temperature sensor they can take high accuracy temperature measurements to verify process temperatures and ensure the highest product quality and safety. There are a variety of different temperature calibrators designed for your unique calibration and testing requirements.
-
product
Liquid Baths & Multi-Liquid Baths
Liquid baths temperature condition fluid for immersing products and immediately exposing them to a specific temperature.Multi-liquid baths provide many constant temperature environments in a single unit. The temperature in each bath may be controlled at different temperatures.
-
product
Temperature Calibration System
Thermal Engineering Associates, Inc.
Systems for determining relationship between temperature-sensing junction voltage versus junction temperature of diodes, integrated circuits and thermal test die. Provides internal current sources, voltage measurement to 1 mV, and temperature measurement to 0.1ºC. 16-channel capability with optional printer and serial port data output.
-
product
NI-9210, 4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module
785043-01
4-Channel, 14 S/s Aggregate, ±80 mV C Series Temperature Input Module - The NI‑9210 includes anti-aliasing filters, open-thermocouple detection, and cold-junction compensation for high-accuracy thermocouple measurements. The NI‑9210 features NIST‑traceable calibration and a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range.
-
product
Electroplating Bath Analyzer
optek’s electroplating analyzers are inline devices designed to measure plating solution’s metal concentration in real time. These analyzers can be designed to accommodate virtually any concentration range. Operationally, the analyzer passes a white light beam through the plating solution to be monitored. Then, light absorbance is measured at two distinct wavelengths, and the difference in light absorbance between the two wavelengths is equated to a plating solution concentration.
-
product
Temperature Controlled Air Bath
9300A
Measurements International Ltd.
The model 9300A series of Temperature Controlled Chambers is designed as a convenient and inexpensive way to maintain the temperature of air resistors in the calibration laboratory. It is large enough to house several standard air resistors and features two adjustable shelves to permit easy access to the standards. The shelves are easily removable.
-
product
Portable Temperature Calibrators
Portable temperature calibrators (dry-well calibrators) are electronic controllers which automatically, quickly and dryly supply a temperature. Due to the high reliability, accuracy and simple operation, portable temperature calibrators are particularly suitable as a factory/working standard for the automatic testing and/or calibration of temperature measuring instruments of all types. A major advantage is offered by the large sleeve diameters and the fast, stable temperature control, since, as a result of these characteristics, the time for calibration can be used very effectively.
-
product
Humidity and Temperature Calibration
The most comprehensive temperature, humidity and dew-point calibration offering on the market today.
-
product
Dry Block And Bath Calibrators
These units are used to calibrate sensors such as thermistors, thermocouples and RTD's. Different temperature ranges, accuracies and stabilities to cover most sensor specifications.
-
product
Liquid Thermal Shock Baths
TSB Series
CSZ's Liquid thermal shock chambers consist of separately controlled hot and cold baths. Product is submersed in fluid and thermally stressed between the hot and cold baths, resulting in immediate product temperature changes. CSZ uses perfluorinated fluid that does not coat the product or conduct electricity for use in both the hot and cold baths to eliminate cross contamination and reduce evaporation losses.