Torque Tester
TorqueLab® LTT-Series
The torque analyzer is designed for calibrating tools, joint testing, auditing and measuring torque. Torque tools go out of calibration with use. To maintain consistent accuracy, torque tools must be checked periodically for wear or defective parts. A power or hand torque tool is a measuring tool that must be properly calibrated and maintained.
-
product
10 MHz To 67 GHz LAN Wide Dynamic Range Average Power Sensor
L2057XA
Accurately measure any modulated signal with the Keysight Technologies, Inc. U/L2050/60 X-Series wide dynamic range power sensors. The USB/LAN connectivity models come with a wide dynamic range, covering -70 to +26 dBm. This sensor offers very accurate and repeatable power measurements for any modulated signal and comes with a super-fast measurement speed of 50,000 readings/sec, which enables higher manufacturing throughput. Users can also save time and reduce measurement uncertainty with the internal zero and calibration function. The U/L2050/60 X-Series is supported by the Keysight BenchVue software. BenchVue makes it easy to control your power meter to log data and visualize measurements in a wide array of display options without any programming. Simply connect the sensor to your PC installed BenchVue BV0007B Power Meter/Sensor Control and Analysis app to perform average power measurement and analysis.
-
product
Web Sensor with PoE
T3610
PoE Web Sensor with built-in relative humidity and temperature sensors. High precision capacitive polymer sensor ensures excellent long term calibration stability and ultimate accuracy. Dual line LCD is an advantage. Power over Ethernet feature according IEEE 802.3af is supported. Measured values are also converted to other humidity interpretation: dew point temperature, absolute humidity, specific humidity, mixing ratio and specific enthalpy.
-
product
FD-11637, 8-Channel Strain/Bridge Input Device for FieldDAQ
785641-01
8-Channel Strain/Bridge Input Device for FieldDAQ - The FD-11637 can measure eight channels and has built-in bridge completion and voltage excitation to support for quarter-, half-, and full-bridge sensors. It also features anti-alias filtering, offset nulling, and shunt calibration to reduce the effect of noise and improve measurement accuracy. The FD-11637 has an ingress protection rating up to IP67 (dust- and water-resistant), can operate in -40 °C to 85 °C environments, and can sustain 100 g shock and 10 grm vibration. The FD-11637 incorporates Time Sensitive Networking (TSN) and features an integrated network switch and built-in power circuitry for simple daisy chaining. You program the FD-11637 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. The FD-11637 is ideal for test cell and outdoor environments.
-
product
Antenna Measurement Software
Raymond RF's Antenna Measurement Software performs 2-D (polar/rectangular) and 3-D (spherical) antenna pattern measurements for passive antennas and active wireless mobile stations (cell phones). Insertion loss of passive devices is included as part of the calibration component. Data management and reporting of antenna properties such as half power beam-width, directivity, gain, radiation efficiency, total radiated power, and total isotropic sensitivity. AMS performs and reports all measurements required by the CTIA Over-the-Air Performance Test Plan.
-
product
Thermistor Power Meter
N432A
Keysight N432A is the replacement for Keysight's legacy 432A analog thermistor power meter. The single-channel, average RF power meter operates with the Keysight 8478B and 478A thermistor mounts. The N432A-and-thermistor-mount pair is ideal for applications that require high measurement accuracy, particularly in metrology and calibration laboratory environments. The enhanced thermistor power meter comes with a digital color LCD display, and user-friendly front panel interface. Its built-in calibration factor table provides a more convenient and accurate method of storing calibration factors as compared to the old knob-turning approach of the 432A. The N432A is LXI compliant, and programmable via GPIB, USB and LAN.
-
product
CW Power Sensors
E-Series
Operates with the EPM, EPM-P and P-series power meters Wide dynamic range sensors (-70 to +20 dBm)Accurate CW average power measurements Wide frequency coverage from 10 MHz to 26.5 GHz (sensor dependent)Calibration factors stored in EEPROM
-
product
Three Phase Meter Test Bench
Supreme Instrument Laboratories
Three phase meter test bench suitable for calibration & testing of AC Ammeters, Voltmeters, Single phase Energy Meters, Watt Meters, Power Factor Meters, Three Phase Two Wire & Three Phase Four Wire Energy Meters Trivector Meters, Maximum demand indicators, of active & reactive systems, Three phase 3 wire & 4 wire watt meters, Var Meters, Power Factor Meters etc.
-
product
Open-Short-Load RF calibration kits
Open-Short-Load RF calibration kits from Fairview Microwave are available with Type N or 7/16 DIN connectors. Type N open-short-load RF calibration kits have male or female genders, 7/16 DIN open-short-load kits are male gender. Type N open-short-load (OSL) calibration kits for RF have a minimum frequency of 0 (DC) and a maximum frequency range between 4 GHz and 6 GHz. Type N open short load kits for calibration have a maximum power handling of between 1 Watt and 2 Watts.
-
product
Field Strength Meters
FIM-22 And FIM-41
The Models FIM-22 and FIM-41 are portable field strength meters designed to provide precise, direct measurements of electro-magnetic fields in the 200 kHz to 5.0 MHz spectrum. These units include a receiver, integral shielded loop antenna, precision attenuator, internal calibration source, and battery power supply. With calibration accuracy traceable to the National Institute of Standards and Technology, the FIM-22 and FIM-41 meet the most exacting requirements of government and industry. Their hinged covers, on the rugged drawn aluminum cases, contain a loop antenna. Opening the cover to a vertical position connects the antenna terminals to the receiver via maintenance-free gold-plated contacts. An interlock switch prevents inadvertent battery discharge when the cover is closed.
-
product
Three Phase Electrical Power Calibrator
6003A
The Fluke Calibration 6003A Three Phase Electrical Power Calibrator is the most cost-effective way to get the superior accuracy and performance of three independent phases in one instrument. It is an ideal solution for calibration laboratories, electronics manufacturers, electric utility meter shops, and other organizations that manufacture and maintain energy meters, power quality analyzers, and similar tools.
-
product
Breakaway Torque Tester
Automatic Breakaway Torque Tester can be used to verify the actual tightened torque of a bolt. Torque controlled power tools are set to apply consistent torque, but fasteners are not necessarily tightened to that value if the tools are out of calibration. Breakaway torque tests require a skilled, experienced operator to sense when the bolt begins to breakaway.
-
product
- Optical / RF Converter
OPT 80
Calibrated measurement of the optical power of satellite and terrestrial TV signals distributed in optical fiber Calculation of optical signal losses on distribution Measurement of digital parameters (BER - MER - NM etc.) of optical signals converted into RF Visualization of optical carriers in RF Field Metric Spectrum Analyzer Power Meter Optical Field Meter Display Optical RF Power Supply Line Link Meter (LNB power supply ) Optical LNB power supply 13V 500mA with short circuit and overload managementAcquisition of optical measurements using the field meter Data Logger Option: certification of the OPT80 calibration and optical power measurements
-
product
MPO Power Meter, MPO Light Source
JW3224. JW3124
Shanghai Joinwit Optoelectronic Tech,co.,Ltd
JW3224MPO Optical Power Meter and JW3124MPO Optical Light Source is special for testing MPO fiber. At recent years, as the rapid development of data centre and cloud computing, also with rapid growth of multi fibers” (MPO) requirement. However, on the site of measurement process, traditional single channel Optical power meter with complex measurement and low credibility. Based on this, JW3224&JW3124 MPO products arises at this monment. The product can test the insertion loss of MPO fibers and polarity with only one key, And the integration of a variety of data storage, threshold analysis, data export and other applications,Compared with the traditional instrument, the test efficiency of JW3224 & JW3124 is more than 10 times,it is the best choice for field application of MPO room test、calibration of production line、Determination of polarity.
-
product
10 MHz To 54 GHz LAN Thermal Vacuum Compliance Power Sensor
L2066XT
Accurately measure any modulated signal with the Keysight Technologies, Inc. U/L2050/60 X-Series wide dynamic range power sensors. The USB/LAN connectivity models come with a wide dynamic range, covering -70 to +26 dBm. This sensor offers very accurate and repeatable power measurements for any modulated signal and comes with a super-fast measurement speed of 50,000 readings/sec, which enables higher manufacturing throughput. Users can also save time and reduce measurement uncertainty with the internal zero and calibration function. The U/L2050/60 X-Series is supported by the Keysight BenchVue software. BenchVue makes it easy to control your power meter to log data and visualize measurements in a wide array of display options without any programming. Simply connect the sensor to your PC installed BenchVue BV0007B Power Meter/Sensor Control and Analysis app to perform average power measurement and analysis.
-
product
Meter Testing System
ASTel
Three-phase Meter Test Equipment of ASTeL 3.2x.x series system is a fully automatic system enabling simultaneous, multi-position calibration and legalization of electric energy meters. The automatics include power sources, reference standards, stand controllers, photoelectric scanning heads, separating transformers, and other elements of the system. All these elements are controlled through a Windows based executive program.
-
product
CW Power Sensors
E-Series
The E-Series of power sensors have their calibration factors stored in EEPROM and operate over a wide frequency and dynamic range.wide frequency coverage from 10 MHz to 26.5 GHz (sensor dependent)wide dynamic range sensors (-70 to +20 dBm)accurate CW average power measurementsoperates with the EPM, EPM-P, and P-series power meterscalibration factors stored in EEPROM
-
product
TorqueLab® Torque Analyzer
LTT-Series
The torque analyzer is designed for calibrating tools, joint testing, auditing and measuring torque. Torque tools go out of calibration with use. To maintain consistent accuracy, torque tools must be checked periodically for wear or defective parts. A power or hand torque tool is a measuring tool that must be properly calibrated and maintained. The LTT-Series is an advanced torque testing and documentation solution. Using a quality torque tester makes a safer world through accuracy and precision. Controlling torque is essential for companies to ensure their product’s quality, safety and reliability isn’t compromised.
-
product
10 MHz To 54 GHz LAN Wide Dynamic Range Average Power Sensor
L2056XA
Accurately measure any modulated signal with the Keysight Technologies, Inc. U/L2050/60 X-Series wide dynamic range power sensors. The USB/LAN connectivity models come with a wide dynamic range, covering -70 to +26 dBm. This sensor offers very accurate and repeatable power measurements for any modulated signal and comes with a super-fast measurement speed of 50,000 readings/sec, which enables higher manufacturing throughput. Users can also save time and reduce measurement uncertainty with the internal zero and calibration function. The U/L2050/60 X-Series is supported by the Keysight BenchVue software. BenchVue makes it easy to control your power meter to log data and visualize measurements in a wide array of display options without any programming. Simply connect the sensor to your PC installed BenchVue BV0007B Power Meter/Sensor Control and Analysis app to perform average power measurement and analysis.
-
product
Power and Energy Automated Calibration System
RS-933
The RS-933 Syntron Power and Energy Automated Calibration System calibrates a range of test equipment including; Energy Reference Standards, Digital Multimeters, Phase meters, Energy meters, Power meters, Revenue meters, Amp meters, Panel meters & Power Quality meters.
-
product
Leeb Hardness Tester
THL210
LCD display of 128×64 matrix with back-light, showing all functions and parameters. Converts to all common hardness scales (HV,HB,HRC,HRB,HRA,HS). English displaying and easy and convenient menu operation. Powerful PC Software available and USB 1.0 interface and USB with Protective Membrane. 7 types of Impact Device optional, which don't need to be recalibrated when changing them. Memory of 600 groups data(impact times:32~1). Lower limit setting and sound alarm. Material of “cast steel” is added; HB values can be read out directly when D/DC impact device is used to measure “cast steel” work piece. Printer be separated from main unit and copies of testing results can be printed as required. Normal battery AAA and big power store while USB connected and charging controlling circuit. Inbuilt function of Software Calibration.
-
product
Three Phase Power Meter
929A
Model 929A Three Phase Power Meter is an economical alternative to both the Model 931A Power System Analyzer and the Model 930A Three Phase Power Analyzer when serial communication, dc voltage measurement, transducer calibration and timer features are not required. The Model 929A has the same ac accuracy as the Model 931A with PowerDSA™ Digital Signal Analysis, and is a complete diagnostic tool for use in the substation and industrial power environment.
-
product
Vector And Scalar Mixer / Converter Measurements
S95083B
The Keysight S95083B measurement software includes the scalar mixer / converter plus phase (SMC+Phase) measurement class. It provides fully calibrated conversion gain / loss, relative phase, and absolute group delay measurements of mixers and converters without the need for reference or calibration mixers. Eliminating the calibration mixer requires a U9391C / F / G comb generator and an external DC power supply. A vector mixer characterization (VMC) is also included for measuring group delay of frequency-converting devices. VMC can be used to characterize a user-supplied calibration mixer.
-
product
Three Phase Power Analyzer
930A
Model 930A Three Phase Power Analyzer is an economical alternative to the Model 931A Power System Analyzer when the dc voltage measurement, transducer calibration and timer features are not required. The Model 930A has the same ac accuracy as the Model 931A with PowerDSA™ Digital Signal Analysis. Basic accuracy of 0.05 % of reading and 0.05 ° phase, harmonic analysis, and full three-phase capability are standard.
-
product
Low Torque Reaction Sensors
MTX
The MTX is a low torque sensor designed for calibrating and testing small hand screwdrivers, torque wrenches and power tools. With its low profile design, the calibration instrument can be used for automated applications, by mounting it to a palletized system. This saves time as there is need to remove the driver from the robot or off the automated system for calibration. These versatile torque sensors are used in conjunction with a torque tester.
-
product
Switch Amp
One of many potential designs, Teledyne RF & Microwave's switched amplifier covers 100 to 2000 MHz, providing 18 dB gain, phase matched to within ±1.0 degree. The primary RF input and a secondary calibration signal input are switched, then amplified, and split to two outputs. Gain balance between any of the two outputs is ± 0.5 dB. Output power at 1 dB compression is +14 dBm and input/output VSWR is 2.0:1 maximum.
-
product
Thermocouple Simulator Module for SLSC
Bloomy’s 8-Channel Thermocouple Simulator Module provides eight channels of galvanically-isolated thermocouple simulation and simulates types E, J, K, M, N, and T thermocouples. High-precision digital-to-analog converters which are isolated from each other and from system power provide sub-microvolt resolution and accuracy. Built-in switching provides open-circuit faults as well as switching to system calibration resources.
-
product
Resistivity Meter
Model 2180
The unit is compact and lightweight. The basic system is 7″ wide by 2.5″ high and 12″ long. When measurements are needed below approximately 100 micro-ohm-centimeters, the basic system is piggybacked onto a second enclosure that houses a power amplifier with a current gain of ten. The combined unit measures 7″ wide by 5″ high and 12″ long. The combined unit weighs 11.5 pounds. Two short cables interconnect the two enclosures for powering the power amplifier and routing the signals to the fixture or four point probe. The front panel of the basic system includes a 32-character backlit LCD display and a set of function keys. An easy-to-use menu will allow access to user defined parameters such as sample thickness, sample volume, and calibration constants; upper and lower alarm limits, relative measurements, and several others.
-
product
Wavelength and Power Meter
WPM-1NM
•Wide range Wavelength Meter– Auto λ detection from 1270nm to 1610nm– Auto power calibration & display•FTTx/PON Wavelength Meter– 1310/1490/1550nm auto λ detection– Auto power calibration & display•Optical Power Measurement– Optical network power measurement– Power measurement for system & module•Insertion Loss Measurement– Optical network & component IL measurement– IL measurement for CWDM 16-wavelength•Smartphone Interface– Communicates with smartphone via bluetooth– Smartphone application software
-
product
Attenuators And Pulse Limiters
A bidirectional attenuator, i.e. the attenuation and power capability specification is valid for both directions. There is a large variety of applications for this attenuator: The measuring range of a spectrum analyzer can be increased. Any kind of meter can be protected against overload; it can be used to control the linearity of a meter reading. It can minimize measurement uncertainty caused by mismatched impedances. During an EMI receiver calibration an attenuator directly at the pulse generator output is inevitable.