Filter Results By:
Products
Applications
Manufacturers
Millimeter Wave
extremely High Frequency in the range of 30 to 300 gigahertz.
See Also: Wave, Extremely High Frequency, Long-Wave IR, Lightwave, Shear Wave, Sub-mm Wave, Microwave, Wavelet, Continuous Wave, Submillimeter Wave, Sine Wave, Shock wave, mmWave, MW
-
product
Millimeter-Wave Amplifiers
When your application requires operating at Ka-band and above, trust Mercury Systems’ millimeter wave amplifiers to perform. With standard designs up to 65GHz and custom products available, Mercury is ready to support your high frequency requirement.
-
product
Microwave/Millimeter Wave Devices
We at AET Associates, Inc. take pride in our engineers who have in-depth technical knowledge in the areas of microwave and millimeter wave technology. We hope that we can serve you to benefit your research and development, production, and purchase strategies.
-
product
RF Detectors for Millimeter Wave
RF Detectors are essential microwave/millimeter wave products for most Tx (transmit sources). Transmitter output power measurement is the main application. It is essential to know the RF output power because the output power level must not go above values set by FCC regulations.The unit of power is the watt for RF detectors. But, most commonly used in most RF and wireless systems to express power is the terms of dBm or decibels related to 1 mW:View more RF Detector
-
product
Millimeter Wave Converter
ZVA-Z Series
Millimeter-wave measurements in the V, E, W, F, D, G, J and Y band – network analysis in frequency ranges from 50 GHz to 500 GHz depending on the converter model. Featuring a wide dynamic range, the RPG converters offer high operating convenience and allow fast measurements. Two-port measurements can be performed using a four-port network analyzer and two converters; no external generator is required. When using a two-port network analyzer, an external generator is needed to supply the LO signals.
-
product
Millimeter Wave Continuously Variable Waveguide Attenuators
Our millimeter wave variable waveguide attenuators allow designers and engineers to test their systems at various signal strengths and attenuation values to determine the optimum signal performance of the system. The key feature of these waveguide attenuators is that the attenuation level is adjusted using a built-in micrometer which enables repeatable and rapid re-setting to different attenuation levels without the need for additional external components. Our waveguide attenuators handle varying attenuation levels from 0 to 30 dB over the specified band allowing the designer to tune the attenuation level needed for the application. These continuously variable waveguide attenuators cover a broad frequency range of 33 to 110 GHz in five bands and also display flat performance across a wide band with low insertion loss.
-
product
Millimeter Wave Amplifiers
Ducommun offers Low Noise (ALN), High Power (AHP), Full Waveguide Band (AFB) and General Purpose (AGP) amplifiers to cover the frequency range from 18 to 96 GHz. These amplifiers utilize thin-film and microelectronics manufacturing techniques and are discrete and/or MMIC PHEMT devices based. These amplifiers feature low noise, high output power, single DC power supply and wide operation temperature range. The amplifiers are offered in two categories, standard and custom-built. Both standard and custom-built amplifiers are equipped with various RF interface, including standard waveguide or coaxial connector for convenient system integration. The optional input and output integrated isolators are available as an option to further improve the port return loss.
-
product
Millimeter-Wave Mixers
Teledyne Lincoln Microwave design and manufacture custom Single Balance Mixers for operation up to 110 GHz.
-
product
Millimeter Wave Control Devices
Ducommun millimeter wave products include various control devices for system integration. The CAE, CPS, CPD and CPM series control devices are discrete or MMIC based PIN diode attenuators and switches. The CAF, CAL, CAR and CPL series control devices are waveguide based mechanical tunable attenuators and phase shifters. These devices are offered to cover the frequency range from 18 GHz to 110 GHz.
-
product
Millimeter Wave Zero Bias GaAs Schottky Diode
HSCH-9161
The HSCH-9161 is suitable for medium-low barrier, zero bias detector applications. The HSCH-9161 is functional through W-band (110 GHz) and can be mounted in microstrip, finline, and coplanar circuits.
-
product
Millimeter Wave Products
Reliable Millimeter-Wave High-Power Products for Airborne, Maritime and Ground Mobile Deployment
-
product
THz And Millimeter-Wave Ultra-Fast Sweepers From 36 GHz To 1250 GHz
Insight Product Company introduces a family of Ultra-fast wide band Sweepers of millimeter and terahertz waves (Insight Sweepers). Insight Sweepers cover frequencies from 36 to 1250 GHz and generate substantial output power.
-
product
Millimeter-wave and Microwave GaAs Specialty ICs
Keysight Technologies provides MMIC Specialty ICs ideal for microwave radio, aerospace and defense, and instrumentation applications.
-
product
Millimeter Wave Converters
ZC-Series
*variable output power*wide dynamic range*wide frequency range*highly stable measurement*convenient handling
-
product
Millimeter Wave Orthomode Transducers
We are developing a series of millimeter wave orthomode transducers. These orthomode transducers are fullband, compact components. They achieve astounding cross-polarization while maintaining Micro Harmonics’ impressively low insertion loss.
-
product
110 GHz, 1.0 Mm (m-f) Test Port Cable 10 Cm
11500JK10
Connect test ports to devices, fixtures, or probe tips with this 10-cm cable
-
product
Standard 0.79 (23.40) - 1.75 (49.60) General Purpose Probe
HPA-40G
Current Rating (Amps): 2Average Probe Resistance (mOhm): 35Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 660Overall Length (mm): 16.76
-
product
Coaxial Waveguide Adapter, 1.85 mm (f), 50 to 67 GHz
V281A
The Keysight V281A adapter transforms waveguide transmission line into 50-ohm coaxial line. Power can transmitted in either direction, and each adapter covers the full frequency range of its waveguide band with SWR less than 1.3.
-
product
P2664 General Purpose Probes
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
product
Alternators
Ducati Energia alternators are permanent magnets generators available in a power range of 60 W – 5.000 W and diameter between 95 mm and 180 mm.
-
product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-1W1S
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
product
HPA-74 General Purpose Probes
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
product
Standard 1.50 (43.00) - 3.00 (85.00) General Purpose Probe
P2665G-2W1S
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
product
Coaxial Waveguide Adapter, 1.85 mm (m), 40 to 60 GHz
U281B
The Keysight U281B adapter transforms waveguide transmission line into 50-ohm coaxial line. Power can transmitted in either direction, and each adapter covers the full frequency range of its waveguide band with SWR less than 1.3.
-
product
Non-Replaceable General Purpose Probe - Epoxy Mount
MEPJ-22BD
Current Rating (Amps): 2Average Probe Resistance (mOhm): 125Test Center (mil): 20Test Center (mm): 0.51Full Travel (mil): 79Full Travel (mm): 2.01Recommended Travel (mil): 52Recommended Travel (mm): 1.33Mechanical Life (no of cyles): 50,000Overall Length (mil): 810Overall Length (mm): 20.60Rec. Mounting Hole Size (mil): 13.8Rec. Mounting Hole Size (mm): 0.35Rec. Mounting Hole Remark: 13.5 to 14mil / 0.34 to 0.36 mmRecommended Drill Size: #80 or 0.35 mm
-
product
Alternate 2.65 (75.00) - 6.50 (184.00) Bead Probe
BTP-25C-6.5
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
product
Pneumatic Contact, Receiver, Hose Barb, for 1/8" [3.2 mm] ID Tubing
610132105
Primary mating contact 610131106.Pneumatic Connectors are available with either ferruless polytube fittings (3/8" tubing OD) or hose barb (3/8" tubing ID). Ferrules fittings securely attach tubing without hose clamp - which is recommended for the hose barb type (hose clamp not included). The 1/8" ID connectors are available with hose barb.
-
product
Bond Tester for Wafers 2 - 12 inch
Sigma W12
Bondtester for wafers or at wafer level 2” – 12” (up to 300 mm)Precise testing and Cold Bump Pull (CBP) testingLarge X/Y stages X: 600mm, Y: 370 mmForce range from 1gf – 10 kgfBump pitch down to 20 µm
-
product
Elevated 2.67 (76.00) - 7.00 (198.00) High Performance Lead Free Probe
LFRE-72T1-7
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
product
Compact Case 20 EMC S-200 mm Case
20E-201-200
The Compact Case 20 combines flexibility, practicability and intelligent design. Available in four different sizes and three different finishing options. Optionally also with EMC protection.
-
product
A-A-S General Purpose Probes
Current Rating (Amps): 2Average DC Resistance lower than (mOhm): 30Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 30Full Travel (mm): 0.76Recommended Travel (mil): 20Recommended Travel (mm): 0.51Overall Length (mil): 310Overall Length (mm): 7.87Rec. Mounting Hole Size (mil): 31.5Rec. Mounting Hole Size (mm): 0.80Recommended Drill Size: #68 or 0.79 mm