Filter Results By:
Products
Applications
Manufacturers
Impedance
-
product
Calibration Kit
N1.2
*N1.2 Calibration Kit, * Frequency Range: up to 1.5 GHz, Impedance: 50 Ohm, * Connector Type: N-type.
-
product
Differential Probe
DP-800HS
*1:1 High Sensitivity*100 Gain Design*x1, x10, x100 Attenuator*Bandwidth: DC-50MHz*Input Impedance 3MΩ // 2.5PF*Max. 800Vp-p Input or ±400V DC or AC 280V RMS*Output Impedance 50Ω
-
product
Calibration Kit
F7511
F7511 Calibration Kit, Frequency Range: up to 3 GHz, Impedance: 75 Ohm, Connector type: F-type
-
product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40B-012
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
product
High Impedance Active Probes
34A
Engineered to meet the stringent demands of advanced high frequency circuit designers. This high impedance probe combines full DC capability, rise/fall times of 120 ps, and a nominal loading input impedance of 10 megohm shunted by 0.1 pf. Signal attenuation is 20:1 with a 50 ohm oscilloscope input.
-
product
Standard 0.79 (23.40) - 1.75 (49.60) High Frequency Probe
CSP-40A-024
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 225 (5.72) including travel of probes
-
product
RF Adapters
MHV Adapters
MHV Jack to MHV Jack Adapter Non-Constant Impedance Straight 4-Hole Flange.
-
product
High Impedance Active Probes
35
The Picoprobe Model 35 has been engineered to meet the stringent demands of advanced high frequency circuit designers.
-
product
Impedance Analyzer 1MHz-20Hz
IA1000
Frequency range20 ~ 1MHzFrequency accuracy0.005%Frequency resolution0.001% in all frequency rangeTest signal level0.05 ~ 2.0 VrmsTest signal resolution0.001 VrmsTest signal output impedance100ΩImpedance Z range; basic accuracy0.0000Ω ~ 99.99
-
product
Line Impedance
KIT
The Line impedance kit is composed of two modules, STLG and STSG. The kit is meant to be used with STS 5000, STS 4000 and eKAM in order to perform Line Impedance test.
-
product
Impedance Analyzers
The E4990A Impedance Analyzer with a frequency range of 20 Hz to 120 MHz provides an industry best 0.045% (typ.) basic accuracy over a wide impedance range, with a 40 V built-in DC bias source.
-
product
Generator & Earthing Series
Kvtester Electronics Technology Co.,Ltd
AC Impedance Tester is the newly developed enhanced impedance tester on the basis of improving and perfecting the old model product. The instrument has three new functions: equipped with rotating mouse to achieve easier operation; display and print AC impedance characteristic curves; achieve data download and editing the test report with PC online. This instrument adopts the most advanced high-speed microprocessor with more powerful function and better performance. It is well established for its high reliability, simple operations, high accuracy and lightweight. Currently the instrument is in leading position in china.
-
product
Time Domain Reflectometer
STEP TDRS
Cable Measurements: Distance, Fault Types, Distance to Faults, Impedance Readings, and Loop Resistance.
-
product
Impedance Matching Pads
These impedance matching pads are resistive networks that can be used to match 2 devices with different nominal impedances. The resistive network used in these impedance matching pads has a 5.7db theoritical insertion loss; true loss is 5.7db plus the normal other losses. common use is to connect 50 ohm sma's to 75 ohm f's. There are also 75 ohm versons of N's, BNC's, & SMA's.
-
product
COMPUTERIZED LCRTZ TEST SYSTEM (Automatic Transformer Test System)
CVCT-S20
Ideal for fast and fool proof testing of COILS AND SMALL TRANSFORMERS like SMPS transformers, Telecom transformers (HYBRID, POT CORE, RM-CORE), Pulse transformers etc. The systems scans at one stroke, all the windings of a transformer and tests as per definition of test procedure. The test procedure can be pre-programmed and stored under User friendly menu driven software . Any semi-skilled and unskilled person can be engaged for actual testing purpose. Can Select test frequency, pin number, parameters, test conditions, limits for each test. Test any pin to any other pin any defined parameter.Test Parameters :-> Inductance-> Capacitance-> AC Resistance, -> DC Resistance, -> Impedance, -> Leakage Inductance,-> Transformation Ratio & Winding PolaritySPECIFICATIONS :Measurement Frequencies : 50 Hz, 100 Hz, 500 Hz, 800 Hz; 1 KHz, 2 KHz, 5 KHz, 10 KHz. Measurement Voltage: 0.1 V – 1.0 V RMS adjustable under program control.
-
product
Overhead Line & Cable Impedance Test Sets
T&R Test Equipment Overhead Line & Cable Impedance Test Sets
-
product
Test Services
D-Coax offers RF/Microwave test services for your researchprojects, as well as, production quantities tests. We have available resources and expertise in the high frequency interconnects testing that will benefit your research and products. We will work with you to make your requested tests the most accurate and reliable and we'll complete them in a timely fashion. The following parameters can be characterized or tested to specifications with our test services: Time Domain: Impedance, Impedance profile, rise time, propagation delay, skew and more. Frequency Domain: S21 - Insertion loss, S11- Return loss, S12 - Reverse Insertion loss (port 2 insertion loss), S22 - Reverse Return loss (port 2 return loss) and more.
-
product
Ground Pro Meter
Verifies Critical Grounding Parameters of a FacilityMeasures AC voltage, DC voltage, EMI voltage and AC impedanceProvides Accurate Measurements of Ground Impedance on a Working ToolMeets ANSI/ESD S20.20 requirements for AC impedanceIdentifies Potential EOS Generators
-
product
Single Channel Potentiostats
12XX Series
The 12xx Series Potentiostats has two current models: the 1287A and 1280Z. This family of potentiostats communicate through trusted GPIB interface technology that can convert to USB for easy connection modern computers. The Solartron Analytical 1287A and 1280Z are often driven by CorrWare software for DC testing, such as Cyclic Voltammetry, and ZPLOT for AC testing, such as Electrochemical Impedance Spectroscopy.
-
product
Impedance Matching Pads
Impedance matching pads from BroadWave eliminate impedance discontinuity (mismatches) without introducing reflection to the circuit. Custom units are available in a variety of impedance and connector types from DC to 4 GHz. BroadWave Technologies impedance matching pads preserve signal integrity by matching virtually any transmission line.
-
product
Speaker Component Checker
Cab Driver
Whirlwind Music Distributors, Inc.
The CAB DRIVER is a test device for checking the operation of the speaker components within enclosures. A pink noise signal source is sent through pushbutton selectors to an assortment of speaker connectors, including Speakon NL8 and NL4, 1/4" TS and banana jacks. Speaker/ Polarity/ Impedance/ Pink Noise Generator
-
product
Impedance Analyzer 10MHz-20Hz
IA1021
Feature Specifications: Dual test mode: Analyzer(frequency sweep) and LCR(single frequency).Measurement frequency: 20Hz to 10MHz, 6 digitsFrequency resolution: 0.001% in all frequency rangeFrequency accuracy: 0.01%.DC bias(program): -10V ~ +10V, 0.005V resolution, accuracy 0.5%.Measurement basic accuracy: Impedance +-0.2%, phase: +-0.1°.Display Range: Z: 0.0000Ω-99.999MΩ.
-
product
High Impedance Active Probes
7
Designed as a companion probe to Models 12C and 18C for driving integrated circuit lines so the Model 12C and 18C can be used to measure the response of adjacent nodes. The Model 7 consists of a flexible 6 foot, 50 ohm coaxial cable accurately terminated to 50 ohms in order to avoid undesirable reflections. A special miniature connector receives replacement coaxial probe tips that provide a shielded environment to within 3 mm of the fine tungsten probe point, thus minimizing capacitive coupling to other parts of the circuit. The replaceable coaxial probe tips are offered in various point sizes and can also be bent to any shape in order to accommodate a variety of probing geometries.
-
product
5uH Line Impedance Stabilisation Network LISN - CISPR 25
TBOH01
The TBOH01 5H LISN is a device required to setup conducted noise measurements of DC-powered devices. It is designed to be used for EMC pre-testing in the frequency range of 150kHz to 110 MHz.
-
product
Vector Network Analyzers
The VIA Bravo is a handheld Vector Impedance Analyzer for measuring the impedance and resonant frequencies of circuits and antennas. The VIA Bravo has the capability of providing accurate measurements and sweep displays of impedance, reactance, resistance, phase angle, return loss and SWR. The VIA Bravo’s testing functionality, combined with its 100 kHz to 200 MHz frequency range, make it a versatile tool for many service applications including areas such as MRI, wireless telemetry, 2-way radio, aviation, and Radio Frequency Identification (RFID).
-
product
Controlled Impedance Field Solver
Si8000m
TheSi8000m is an all new boundary element method field solver , which builds on the familiar easy to use user interface in earlier Polar impedance design systems. The Si8000m adds enhanced modeling to predict the finished impedance of multiple dielectric PCB builds and also takes into account the local variations in dielectric constant on close spaced differential structures.
-
product
High Impedance Transformers
Osborne high impedance transformers are used to step-up, step-down and isolate voltages in single phase and three phase circuits. A properly designed high impedance transformer can be used an an equivalent to an isolation transformer connected in series with an inductor. The high impedance characteristic may be employed as a current limiting feature in both the primary and secondary circuity.
-
product
Impedance Analyzer, 20 Hz to 10/20/30/50/120 MHz
E4990A
The E4990A Impedance Analyzer has a frequency range of 20 Hz to 120 MHz. The E4990A provides an industry best 0.045% (typical) basic accuracy over a wide impedance range, with a 40 V built-in DC bias source. The equivalent circuit analysis function supports seven different multi-parameter models and helps you to simulate your own equivalent parameter values of components.
-
product
High Impedance Active Probes
18C & 19C
High impedance probes, PICOPROBE® MODEL 18C and MODEL 19C, combine the most advanced MOS and bipolar technologies with special, low capacitance packaging techniques to achieve truly remarkable electronic measurement capabilities. While being manufactured each instrument is individually optimized for the best possible performance. The extremely low input capacitance, high input impedance, and almost negligible input leakage current permits the direct probing of even the most sensitive MOS dynamic nodes. At the same time, the full dc capability of this Picoprobe coupled with the high speed capability permits the full characterization of circuits.
-
product
Calibration Kit
S2611
*S2611 Calibration Kit, * Frequency Range: up to 26.5 GHz, * Impedance: 50 Ohm, * Connector type: 3.5 mm female.