High Voltage Probes
handle voltages beyond general purpose passive probes and operate in the range >500 volts and <20,000 volts.
See Also: High Voltage Meters
-
product
500 MHz Passive Probe, 2.5mm, 10:1, 10 MOhm
PP022-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
High-Voltage Differential Probe, 200 MHz
N2805A
The N2805A is a 200-MHz differential probe designed to provide superior differential signal measurements with long cable length (5 m), making it ideal in an environment where extended cable length is required. The probe offers 50:1 attenuation ratio, allowing it to be used adequately for up to ±100V DC+peakAC of high voltage differential measurements with high CMRR. The differential probe has a differential input resistance of 4 MΩ and low input capacitance of 4 pF to minimize circuit loading. The probe is powered by Keysight’s oscilloscope AutoProbe interface.
-
product
Differential Probe
With signals becoming faster, and power supply voltages going lower, these active differential probes will allow floating measurements from 100uVolts to as high as 7000 volts. These probes provide high CMRR and a broad frequency range.
-
product
Replacement Pincer Clips for High Voltage Differential Probe
PK-HVA-02
Replacement Pincer Clips for High Voltage Differential Probe
-
product
1kV, 120 MHz High Voltage Differential Probe with Auto Zero Disconnect
HVD3106A
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
product
High Voltage Probe
HVP-40DM
*DC 40KV CAT II Pollution 2.*2000MΩ Impedance.*3999 LCD display.*Accuracy 1.0% full range.*T.C. 100 ppm/oC*400V/4KV/40KV, 3 range.*Resolution 0.1V/1V/10V.*PEAK HOLD, Auto power off.*CE, TUV GS, UL, CUL, IEC1010
-
product
OverHead Lines Contact Voltage & Low Voltage Indicator
LVD-415
Standard Electric Works Co., Ltd
● No batteries required.● Every circuit is doubled.● Buzzer indicates voltage detected.● Led indicates voltage detected.● Neon scale indicates voltage.● Dual HBC fuses.● High grade fiber glass probes.● Super polished fiber glass.● High strength connecting cord.● Heavy duty rated.● Replaceable tips.● Choice of tips available.● Lightweight.● Small storage space.● Strong strength reliefs.● Double poles non-polarized.● Suitable for 45 to 70 Hz networks.● Contact detector type.● Passive circuitry.● Fiber glass 1.6mm - CU 35um PCB.● Super bright neon lights and LEDs.● Ergonomically-designed.● EN 61010-031 CAT IV 500V.
-
product
High Voltage Probe
PD-28
Kusam Electrical Industries Limited
Most Digital Multimeters can measure AC Voltage up to 750 /1000V and DC Voltage upto 1000V DC. To extend the measuring range of the digital multi meter for low - power , high - voltage , high impedance circuits such as TV, Video Monitors.
-
product
High Voltage Probe
CP-3308R
*100:1 scope probe *300MHz Bandwidth *Read out Function *Division Ratio x 100 *100MΩ Fix Input Impedance *1500V DC Working Voltage (CAT Ⅱ) *2000V AC peak to peak MAX. (CAT Ⅰ) *CE Approved.
-
product
High Voltage Clip for Test Leads
- The new Parrot clips are high voltage gripping clips for test leads and probes. High Voltage Parrot clips replace insulated alligator clips, plastic coated miniature alligator clips, small crocodile clips or large alligator clips.- Parrot Clips have a design with a new metal tube tip which is connected directly to the lead.- The tip, the hooked rod and the spring are housed in a plastic support.
-
product
Injection Transformer
J2101A
The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.
-
product
Acute High Voltage Differential Probe, 50x/500x, 100MHz, 3500V
ADP5100
*USB Powered (or Power Bank)*Bandwidth up to 100 MHz*Overrange Indicator*Audible Overrange Alarm*Bandwidth Limit : 5 MHz / Full*Can be used by any DSO which has the USB port(s).*EC Declaration: EN 61010-031:2002 +A1:2008*Double-layer wire for power insulation
-
product
Attenuation 100 High Voltage Passive Probe
Safe high voltage probe solutions for ground-referenced voltage testing. It is critical to safely and accurately capture real-time signal information from "elevated" or "floating" voltage systems.
-
product
500 MHz Passive Probe, 5mm, 10:1, 10 MOhm
PP024-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
High Voltage Probes To Measure Primary Waveforms With A Power Analyzer
Volt Litewire
The Litewire is a true RMS meter designed for use by electric utilities to sense currents or voltage waveforms from the primary side of their distribution networks.
-
product
Injection Transformer
J2100A
The injection transformer is presently the prevalent method for connecting the network analyzer to the circuit being tested, and is primarily used for control loop stability measurements. The goal of the transformer is to inject a signal into the control loop being measured, without impacting the performance of the loop. In order to accomplish this to a reasonable degree, The transformer is isolated and therefore is capable of floating on a high voltage, such as a Power Factor Corrector (PFC), which is often close to 400VDC. Measuring voltages that exceed the voltage rating of the FRA inputs require attenuation probes.
-
product
TightSight™ Clamp Meter, 1000A AC/DC W/TRMS
61-775
*TightSight™ second display*Tapered jaws with hook tip*True RMS current and voltage*AC/DC voltage*Audible continuity*High frequency rejection**Peak hold*Max/min hold*Data hold*Selectable audible and visual alerts when potentially hazardous voltages are detected at the probe terminals*Selectable auto power off*Backlit display*Low battery indicator*Reads accurately on noisy electrical circuits
-
product
High Voltage Probe
HVP-39pro
* 39KVDC+ACpeak* 900MΩ Impedance* DC~50MHz(-3dB)* 1000:1 for Oscilloscope* Very Low Nosie
-
product
Acute High Voltage Differential Probe, 10x/100x, 100MHz, 700V
ADP1100
*USB Powered (or Power Bank)*Bandwidth up to 10 MHz*Overrange Indicator*Audible Overrange Alarm*Bandwidth Limit : 5 MHz / Full*Can be used by any DSO which has the USB port(s).*EC Declaration: EN 61010-031:2002 +A1:2008*Double-layer wire for power insulation
-
product
Replacement Alligator Clips for High Voltage Differential Probe
PK-HVA-01
Replacement Alligator Clips for High Voltage Differential Probe
-
product
Digital Teslameters/Gaussmeters
S Digital Teslameters offer accurate, high resolution measurement of magnetic flux densities, withdirect digital readout in tesla or gauss, and serialcommunications by fiber optics or RS-232C for system applications.The instruments are light and compact, and the probes are easy to use. The DTM-151 has been engineered to withstandthe severe electrical interference produced by high voltage discharge.
-
product
1.5kV, 200 MHz, 2 pF, 10 M, Rise Time < 1.75 ns, High Voltage Differential Probe
T3HVD1500-200
1.5kV, 200 MHz, 2 pF, 10 M, Rise Time < 1.75 ns, High Voltage Differential Probe.
-
product
High Impedance Active Probes
12C
A high speed, high input impedance active probe for measuring the internal node voltage of integrated circuits. The input is 1 megohm shunted by 0.1 pf and the rise/fall times are 0.8 ns. This instrument has full dc capability and can be used with any oscilloscope. The Model 12C was specially designed so that when used in conjunction with a high input impedance oscilloscope, signal attenuation is 10:1 and with a 50 Ohm input, signal attenuation is 20:1.
-
product
High Voltage Optically Isolated Probe, 1 GHz Bandwidth. Includes soft-carrying case.
DL10-ISO
The DL-ISO enables highest confidence in GaN and SiC device characterization with highest accuracy, best signal fidelity, and comprehensive connectivity.
-
product
700 V, 25 MHz High-Voltage Differential Probe (÷10, ÷100)
AP031
The HVD3000A series of high voltage differential probes cover the fullest range of applications, from 120/240 V switch-mode power supplies through 600 V class and 5 kV electrical apparatus. The table below provides a list of recommended probe models based on specific device under test applications.
-
product
Accessory Kit for High Voltage Differential Probe
PK-HV-001
Accessory kit for High Voltage Differential Probe
-
product
Acute High Voltage Differential Probe, 20x/200x, 25MHz, 1400V
ADP2025
*USB Powered (or Power Bank)*Bandwidth up to 25 MHz*Overrange Indicator*Audible Overrange Alarm*Bandwidth Limit : 5 MHz / Full*Can be used by any DSO which has the USB port(s).*EC Declaration: EN 61010-031:2002 +A1:2008*Double-layer wire for power insulation
-
product
500 MHz Passive Probe for HDO4000, 10:1, 10 MOhm
PP018-1
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.
-
product
6kV High Voltage Passive Probe, 500 MHz
PPE6KV-A
High voltage single-ended passive probes are suitable for a wide range of applications where ground-referenced high-voltage measurements must be made safely and accurately. There is also a sense pin to automatically configure the oscilloscope for use with the probe.
-
product
1.5kV, 70 MHz, 2 pF, 10 M, Rise Time < 5 ns, High Voltage Differential Probe
T3HVD1500-70
1.5kV, 70 MHz, 2 pF, 10 M, Rise Time < 5 ns, High Voltage Differential Probe.