Filter Results By:
Products
Applications
Manufacturers
Furnaces
-
product
Digital Contact Thermometers
Digital thermometer can accommodate a wide variety of K-type thermocouple tips that are suited for many types industrial and commercial temperature measurement applications such as Kilns, Ovens, Furnaces, Heat Treating, Ceramics, Pottery, Molten Metal, Crucible and many others
-
product
1 kW and 2 kW Laser-Based Floating Zone Furnace
Laser Furnace
The 1 kW and 2 kW laser furnace for single crystal fabrication is based on a design and developed in close cooperation with the RIKEN Center for Emergent Matter Science under the leadership of Yoshio Kaneko. Both melting zones have 5 lasers each, which guarantees a high uniformity of power density in the melting zone range. The laser profile has been optimized to reduce thermal stress during the crystal growth process. In addition, the system includes an integrated temperature sensor for real-time temperature monitoring. Temperatures up to 3000 °C can be reached and therefore materials with a very high vapor pressure, a narrow temperature range of the melt, a high thermal conductivity coefficient and incongruent melts can be melted.
-
product
Residential/Commercial Combustion Analyzer Kit w/ NOx Sensor/Printer
C165+NKIT
UEi Test & Measurement Instruments
Backed by UEi Service+ to give up to 6 years’ warranty, next day recertification, and a reduced cost of ownership. The C165+ Residential/Commercial Combustion Analyzer is easy to use with a rugged design, multiple sensor protections, altitude compensation and differential pressure. Prints to optional printer and wireless App. The new LINK feature connects the included wireless pipe clamp temperature probes and other optional probes to the C165+. Essential information for installing and maintaining furnaces and boilers all in one device.
-
product
Temperature Standards
ITS-90
The defining instruments of the ITS-90 (International Temperature Scale of 1990) are Standard Platinum Resistance Thermometers (SPRTs) and ITS-90 fixed-point cells. SPRTs are calibrated in fixed-point cells to provide the highest possible temperature accuracy. Primary standards offered by Fluke Calibration include: long-stem SPRTs; capsule SPRTs; triple point of water cells; metal fixed-point cells; maintenance baths and maintenance furnaces for fixed-point cells; standard resistors.
-
product
Flash Diffusivity Analyzers
DLF 2800
The Discovery Laser Flash DLF 2800 is an advanced freestanding instrument for the measurement of thermal diffusivity and specific heat capacity of materials from room temperature to 2800°C. The distinctive design incorporates a proprietary laser, laser optics, detector, and furnace technologies, and along with the unique six-position sample carousel, ensures unprecedented measurement accuracy and sample throughput. With the ability to operate in a variety of atmospheric conditions, including inert gas or under vacuum, the DLF 2800 can characterize a wide variety of materials, including polymers, ceramics, carbons, graphite, composites, glasses, metals, and alloys.
-
product
Residential Combustion Analyzer Kit w/ Printer/Case
C161KIT
UEi Test & Measurement Instruments
Backed by UEi Service+ to give up to 6 years’ warranty, next day recertification, and a reduced cost of ownership. The C161 Residential Combustion Analyzer is easy to use with a rugged design, multiple sensor protections, altitude compensation and now adds a heat exchanger test. Prints to optional printer. Essential information for installing and maintaining furnaces and boilers all in one device.
-
product
Test Fixture Kit
322109
Each kit comes with enough supplies to run 5 tests and we offer all materials separately if you ever need more. These kits can be purchased by themselves, with a furnace or with a test stand. If you have any questions about these fixtures please contact one of our testing experts to get more information.
-
product
LV Iron Core Harmonic Filters
Nonlinear loads such as power electronics based equipment and electric furnaces are sources of harmonic currents leading to harmonic distortion, which is one of the most important parameters for defining the power quality. Most of the commercial loads such as personal computers, photocopy machines, power supplies, and compact fluorescent lamps; and industrial loads such as AC and DC motor drives inject harmonic currents into the network that they are connected to.
-
product
Atomic Absorption Systems
Agilent leads the industry with innovative atomic absorption (AA) instruments. The entry-level SpectrAA 55B is ideal for labs in remote locations, while the 240FS and 280FS AA systems achieve the productivity of sequential ICP with Agilent’s Fast Sequential technology. The 240Z and 280Z AA systems provide superior performance and accurate background correction with transverse Zeeman technology. Our AA Duo systems feature unique simultaneous operation of both the flame and graphite furnace.
-
product
Arc Infrared Carbon and Sulfur Analyzer
CS-8620
Wuxi Jinyibo Instrument Technology Co., Ltd.
Infrared carbon and sulfur analyzer is used together with high-speed automatic ignition furnace to quickly and accurately determines the mass fraction of carbon and sulfur in steel, iron, alloy, non-ferrous metals, cement, ore, catalyst and other materials. a high-tech product integrating light, electromechanical, computer and analytical technology. It has the advantages of wide measuring range, strong anti-interference ability, complete functions, simple operation, accurate and reliable analysis results, etc. It is the ideal for measuring Carbon and sulfur in many industries. Analytical equipment.
-
product
Thermogravimetric Analyzer
TGA-1000/1500
The Thermogravimetric Analyzer TGA-1000/1500 is a thermal analysis instrument that measures weight changes as a function of temperature or time. The system allows for multiple heating, cooling, and isothermal segments to be linked together to achieve a complex profile. Automatic gas switching is also supported during the temperature program. The vertical hangdown design offers stable and smooth weight readings to be recorded during the experiment. The TGA’s small mass furnace responds quickly to changes in the temperature profile and cools down quickly for fast turn around between experiments. Typical analyses for a TGA-1000/1500 include percent weight loss, onset temperature calculations and residual weight.
-
product
OEM Gas Pressure Switch
1996
Reliable and convenient, the 1996-5 and 1996-20 Gas Pressure Switches serve as a compact, low cost switch for gas fired furnaces and equipment. Pressure ranges for both models are ideal for high or low gas pressure interlock. Visible set point and on-off indicators add convenience in servicing
-
product
Chamber/Pyroelectric Task
Radiant's Chamber/Pyroelectric Task sets the sample to a series of temperatures by performingGPIB control of an external thermal device. At each temperature it captures the sample’s polarization response and/or small-signalcapacitance. These are combined to calculate the pyroelectric coefficient. The Pyroelectric Task is to be used with a Radiant Test System and a Linkam Stage (-196C to 600C), Thermal Chambers, Hot Chucks, or a Furnace to automatically measure the Pulse Polarization response and Small Signal Capacitance of a Pyroelectric material that is being heated and/or cooled. Radiant's Pyroelectric measurement Task can be added to Vision at additional cost. This measurement suite fully characterizes the pyroelectric charge (polarization) response of the sample under test. The Pyroelectric Task suite controls various thermal controllers such as Quantum Design, Lake Shore, Delta Design, and many others. Detailed Listing of Thermal Controllers Registered in Vision. The Chamber/Pyroelectric Task is quoted upon request.
-
product
Portable Gas Analyzers
IMR Environmental Equipment, Inc.
Flue Gas Analyzers for residential and commercial applications (HVAC, heating contractors). We also offer hand held Combustion Gas Analyzers and professional Flue Gas Analysis instruments in rugged boxes that can measure combustion efficiency and the emissions of furnaces, boilers etc.
-
product
High Temperature Hot Mountable Furnace Extensometers (1200 Cor 1600 C)
Model 3549
Jinan Testing Equipment IE Corporation
The Model 3549 is a major advancement in the design of externally mounted, furnace extensometers. This new extensometer is designed to meet the stringent requirements of strain controlled testing as prescribed in ISO 6892, while introducing many new innovative features that help improve productivity with static testing applications (tension and compression testing) and long term testing such as low cycle fatigue and creep. The overall design reduces any influence from common lab environment vibrations. This unit also incorporates a new feature that allows the user to precisely set the contact force against the test specimen. This allows for even and repeatable contact force, limiting contact force induced errors. This extensometer mounts on a slide bracket (included) that can attach to the load frame of your test system; optional load frame mounting brackets are available. The gauge length for the 3549 is automatically set prior to mounting on the test specimen, which allows for hot mounting after thermal equilibrium has been reached.
-
product
Carbon/Sulfur Analyzer
EMIA-Step
In addition to the “EMIA-Expert/Pro” series of high-frequency induction furnace type, the “EMIA-Step” of tubular electric resistance heating furnace type has been newly added to our Carbon/Sulfur Analyzers lineup. It realizes highly accurate and sensitive analysis, and its variable heating temperature function enables the quantitative analysis by separating it by temperature and condition as well as whole quantity analysis.
-
product
Residential/Commercial Combustion Analyzer w/ Pressure
C163
UEi Test & Measurement Instruments
Backed by UEi Service+ to give up to 6 years’ warranty, next day recertification, and a reduced cost of ownership. The C163 Residential/Commercial Combustion Analyzer is easy to use with a rugged design, multiple sensor protections, altitude compensation and differential pressure. Prints to optional printer and wireless App. Essential information for installing and maintaining furnaces and boilers all in one device.
-
product
Hydrogen Analyzer
H‑500
Determination of hydrogen using the heat extraction method is a special requirement for the characterization of steel, steel alloys, copper and other metals. ELTRA’s H-500 is designed for the rapid and accurate determination of hydrogen in these materials. The H-500 analyzer uses the heat extraction technique and is equipped with a resistance furnace with quartz tube. The temperature can be set up to 1000 °C in steps of 1 °C. The usual working range of the H-500 is about 900° to 1000° C.
-
product
Sulfur and Carbon Analysis by Combustion
832 Series
LECO’s 832 series will redefine the way you determine sulfur and carbon in a wide variety of organic materials. Using extensive customer feedback and innovative engineering, our latest instrumentation takes advantage of an on-board software platform powered by a touch-screen interface, increasing usability and operational control without using valuable bench space. A high-efficiency combustion furnace, improved IR cell design, and a robust, rugged design make the 832 a valuable resource for any laboratory needing fast and accurate analysis of sulfur and/or carbon in organic materials.
-
product
Heat Technology
In the area of industrial heating technology, our experienced team develops, plans and produces reliable systems for almost every possible area of application. Our product portfolio includes a broad range of heating and drying cabinets, cleanroom dryers, hot-air sterilisers, infra-red and continuous furnaces, and innovative microwave technology too. Alongside our comprehensive selection of series products, we also focus on the implementation of customer-specific, process-integrated solutions.
-
product
Furnaces
AMETEK Sensors, Test & Calibration
The furnace is controlled by a sophisticated temperature control unit that is housed in a separate control console. For high temperature test applications we offer furnaces for use with all dual column test stands.
-
product
Thermocouple Calibration Furnace
9118A
The Fluke Calibration 9118A Thermocouple Calibration Furnace is a horizontal, open-ended tube furnace with a temperature range of 300 °C to 1200 °C. It is used for comparison calibration of noble and base-metal thermocouples by secondary high-temperature labs and instrument shops in industries such as aerospace, automotive, energy, metals, and plastics.
-
product
High-Temperature Extensometers < 1000°C Capacitive
2632 Series
Is typically used in hot tensile applications with tube type furnaces and consist of a separate measuring unit and suspension arm assembly. The measuring unit uses an LVDT with a fixed travel that remains outside of the furnace, the arms are located mostly inside of the heating system and attach the specimen to the measuring unit.
-
product
Tubular Infrared Carbon and sulfur Analyzer
8510-CS
Wuxi Jinyibo Instrument Technology Co., Ltd.
Determination of elements: carbon and sulfur combined measurementAnalytical principle: tube furnace combustion infrared absorption method detectionAnalysis range: carbon: 0.0010%-10.000% ( expandable to 99.9999%) Carbon: 0.0005%-0.500% ( expandable to 99.9999%)Analysis error: carbon: in line with GB/T223.69-1997 standard sulfur: in line with GB/T223.68-1997 standardAnalysis time: 20-100 seconds adjustableElectronic balance: not quantitatively weighed, weighing range: 210g/0.001g
-
product
Reference Thermometers
Reference thermometers (standard thermometers) are, due to their excellent stability and their geometrical adaptations, ideally suited for applications in industrial laboratories. They enable easy comparative calibration in baths, in tube furnaces and in dry-well calibrators. The advantage of reference thermometers is the wide temperature range, and with this, their flexible operation. Furthermore, with their low drift, a long service life is ensured.
-
product
High Temperature Diametral Extensometers (1000 C)
Model 3580
Jinan Testing Equipment IE Corporation
This model is for diametral strain measurement with furnace and induction heating systems. Quartz rods and water-cooling allow the unit to be used for high temperature testing of metals, ceramics and composites. With induction heating, this model often can be used without water-cooling. When used in furnaces, the extensometer is often mounted directly to the furnace side cut-out. Optional load frame mounting brackets are available for supporting the extensometer in cases where furnace mounting is not possible. These optional mounts are used with induction heating or furnace systems. The Model 3580 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
Lab Furnaces
Feature temperatures up to 1600°C and capacities up to 22 liters. They are ideal for applications including heat treating, reacting studies, sintering processes and ceramic firing.
-
product
Residential/Commercial Combustion Analyzer w/ NOx Sensor
C165+N
UEi Test & Measurement Instruments
Backed by UEi Service+ to give up to 6 years’ warranty, next day recertification, and a reduced cost of ownership. The C165+ Residential/Commercial Combustion Analyzer is easy to use with a rugged design, multiple sensor protections, altitude compensation and differential pressure. Prints to optional printer and wireless App. The new LINK feature connects the included wireless pipe clamp temperature probes and other optional probes to the C165+. Essential information for installing and maintaining furnaces and boilers all in one device.
-
product
Pyroelectric and Thermal Testing
The optional Chamber Task measures the Pulse Polarization response and Small Signal Capacitance of a Pyroelectric material that is being heated and/or cooled within a thermal chamber, on a hot chuck or in a furnace. From these measurements the Spontaneous Polarization Pr(q) and the Dielectric Constant er(q) are computed. These are then combined to determine the Electrical Displacement D(q) as a function of the temperature q.





























