Filter Results By:
Products
Applications
Manufacturers
Flux
the rate of flow.
-
product
Hall probes
Axial, transverse, multi-axis, and tangential Hall probes for measuring magnetic flux density. Choose from a wide range of lengths and thicknesses—probes are also available for cryogenic applications.
-
product
Instruments
Advanced Thermal Solutions, Inc.
ATS designs and fabricates the most extensive line of thermal test instruments specifically designed for the electronics industry. These research-quality, state-of-the-art instruments include Pressure, Temperature and Velocity Measurement Systems, Airflow and Heat Flux Controllers, Micron-level Thermography Systems and Cold-Plate Thermal Characterization Systems.
-
product
Heat, Vapor, and Carbon-Dioxide Flux Sensors
Heat, vapor, and carbon-dioxide flux sensors are typically used in eddy-covariance systems to measure exchanges of carbon dioxide, water vapor, and heat between the surface of the earth and the atmosphere.
-
product
Electromagnet
The electromagnet can generate strong magnetic fields for experimental applications. Depending on the required magnetic flux density and Equipment under test volume the air gap can be adjustedcontinuously. The magnet poles come with conical shape close to the test volume to improve accessability and to optimize the achievable magnetic flux density.
-
product
PHOTO-2000Z Multiphotometer
Hangzhou Everfine Photo-E-Info Co., LTD
PHOTO-2000Z can be used for luminous flux (supporting integrating sphere) and illuminance test, portable design, high test accuracy, not only suitable for laboratory, quality inspection department, R&D department, but also for industrial and commercial field measurement.
-
product
Pyranometer Verified Cosine Response
CMP 21
The CMP 21 pyranometer is designed for measuring the irradiance (radiant flux, Watt/m) on a plane surface, which results from the direct solar radiation and from the diffuse radiation incident from the hemisphere above.
-
product
Total Flux Measurement Systems
LED’s and Luminaires must be characterized and tested for brightness and color, for production quality control and also for R&D. The Gamma Scientific Total Flux Measurement System combines our accurate Radoma Spectrometer and an integrating sphere for total flux (total power) and color measurements of LED, micro LED and Luminaires. Measurement parameters include spectrum, lumens, total power, peak and dominant wavelength, CRI, CCT, FWHM and other optical properties.
-
product
0.3M Integrating Sphere For Leds Luminous Flux Test
CX-0.3S
Shenzhen Chuangxin Instruments Co., Ltd.
Thesystem are composed of integrating sphere, spectroradiometer and computer to determine the spectroradiometric and colorimetric parameters, e.g. spectral power distribution, chromaticity coordinates, correlated color temperature, color rendering index, color tolerance, color difference, luminous flux, current, voltage, wattage, etc.
-
product
Fluxmeter
Measures changes in magnetic flux, as detected through a Helmholtz or similar coil arrangement.
-
product
Magnet Temperature Characteristics Apparatus
TDF
Evaluation of thermal stability of varieties of permanent magnets including rare-earth permanent magnet. TDF-5-200auto This apparatus automatically measures and analyzes reversible temperature coefficient(a) and irreversible temperature coefficient (Flux loss ?f) of magnetic flux density of rare-earth permanent magnet in the wide range from low to high temperature.
-
product
Measuring Devices for Magnetically Hard Materials
WB10
The WB10 Fluxmeter is designed to measure the change of magnetic flux in measurements of magnetic properties of the magnetic materials in quasi-static and slowly floating conditions. Fluxmeter is the electronic measuring device with high sensitivity, very small drift as well as very small error of integration in a long time.
-
product
Spectrometers
*Search and detection of gamma radiation sources with automatic identification of the radionuclide composition;*Measurement of the dose rate of gamma radiation;*Detection of neutron radiation and measurement of the neutron count rate (AT6102);*Measurement of the dose rate of neutron radiation (external detection unit BDKN-03);*Measurement of the flux density of alpha and beta particles from contaminated surfaces (external detection units BDPA-01 / BDPB-01)
-
product
Custom Magnetic Recording Heads
International Electro-Magnetics, Inc.
We have manufactured over 5,000 different head designs. If we don't have one to suit your requirements, we will design and build to your specification. Our toolroom is well equipped to produce precision parts, and our design projects have included flux sensing systems, magnetic disk encoding, and electronic test equipment.
-
product
Offline Stator Core Testing
Iris Power EL CID Evolution
The EL CID Evolution provides offline testing of inter-laminar insulation breakdown within a stator core. The only alternative to the Iris Power EL CID Evolution test is the Ring Flux (full flux) test. The Ring Flux test requires large power supplies, considerable manpower, and expensive infrared viewing cameras.
-
product
LED Tester0.3m-2m Integrating Sphere
CX-8000
Shenzhen Chuangxin Instruments Co., Ltd.
Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.
-
product
Photometer
PH2000
• Flux or Lumen measure range depends on the size of the integrating sphere • Light current measuring range: 0.005×10-7A~2000×10-7A • User can do ZERO and Calibrate by operating the keys on the front of panel • Photo Detector: Class 1 • High correcting accuracy of photo detector V(λ) • English Software can be run in WinXP or Win7 by RS-232 (option)
-
product
Integrating Sphere Systems
An optical device for various purposes such as. measuring the radiant flux (optical power) from a laser diode, light-emitting diode (LED) or bulb.
-
product
Hystograph
HG 200
This process runs with constant flux alteration d/dt and avoids interference caused by eddy currents and phase displacement between the field strength and polarization measurements.
-
product
LED626/620 Goniophotometer For LEDs
Hangzhou Everfine Photo-E-Info Co., LTD
It can measure the luminous intensity data and automatically plot the luminous intensity distribution curve and luminous flux, and the test conditions meet the CIE condition A (far field) or condition B (near field).In addition, the software can provide customers with 3D luminous intensity distribution graphic.
-
product
Scanning XPS/HAXPES Microprobe
PHI Quantes
The PHI Quantes is the only commercially available automated, high-throughput lab-based HAXPES spectrometer. It is a unique scanning X-ray photoelectron microprobe that combines a high energy (HAXPES) monochromatic X-ray source (Chromium Kα) with a conventional monochromatic soft X-ray source (Aluminum Kα). Both sources are high flux focused X-ray beams that can be scanned across the sample surface and can be used to define analysis points, areas, lines, and maps with 100% confidence.
-
product
Fluxmeter
480
An advanced tool designed primarily for use in industrial and measurement systems settings, the Model 480 fluxmeter measures total flux from which B, flux density, and/or H, magnetic field strength, can be determined.
-
product
Motor/Gasoline Engine RPM Detector
OM-1500/1200
The OM-1500/1200 motor/gasoline engine RPM detector is designed for rotation measurement of a gasoline engine and an EV/HEV motor. It detects magnetic flux leakage from the motor itself or the engine’s ignition coil.This easy to use and durable detector can measure engine rotation by attaching in parallel with the ignition coil. When the EV/HEV motor rotation is measured, attach the OM-1500/1200 perpendicular to the motor rotating shaft.It is used with the engine tachometer by Ono Sokki (GE-2500, AR-7240B, CT-6520B, HT-6200, SE-1620, FT-2500, FT-7200).
-
product
Irradiance Probe
LPUVA01
The LPUVA01 probe measures irradiance (W/m2) defined as the ratio between the radiant flux (W) passing through a surface and the surface area (m2) in the UVA (315 nm … 400 nm) spectral range.
-
product
Heat Flux Sensors
MF Series
EKO Heat Flow Sensors are applied to measure the heat flow or thermal conductivity in materials and radiative IR flux emitted by body surfaces. The sensors are suitable for indoors applications, some models made for outdoors purposes and are available in different sizes and thickness. All sensors are extremely flat, which is a big advantage considering the minimum interference with the conditions of the testing area the thermal dynamics. Since sensor foils are relatively flexible those can easy be applied on curved surfaces and can be used in different applications to measure the performance of insulating materials in refrigerators, container walls, pipes, building constructions, etc.
-
product
Lamp-Based Calibration Light Sources
Lamp-based calibration light sources from Gamma Scientific are used for optical calibration of light measurement instruments including spectroradiometers, photometers and radiometers. All of our calibration light sources meet rigid quality standards for use in the most challenging testing environments. A wide range of light sources is available to serve as precision standards of radiant flux and white-light standards of spectral irradiance or luminance.
-
product
Light-resistant Integrating Sphere
The integrating sphere is used for total luminous flux measurement. It uniforms the light by spatially integrating the collected light of light source. The integrating sphere has highly reflective diffusing plates formed on the spheres internal surfaces. These plates repeatedly scatter light rays from the light source with in the sphere to all other points to deliver uniform brightness distribution so measuring a portion of that light gives the total luminous flux. These years, the usage of integrating sphere for total luminous flux evaluation of light source is increasing. The large size integrating sphere over 1.5M is required for measuring a high brightness light source and a long light source such as fluorescent light.
-
product
Helmholtz Coil
In the measurement of magnetic fields by means of Hall probes or measuring coils it is necessary to calibrate the instruments in a known magnetic field. Our standard field coil according to Helmholtzenables to production of a magnetic field calculable with high accuracy from the dimensions and the amperage. In series arrangement with an accurate ammeter field strengths of up to 800A/cm are produced. The dield room accessible both in axial and radial direction. Helmholtz coils with fluxmeters are also useful in testing of magnets. Helmholtz coils give repeatable results as against the search coils due to which the magnets can be compared with more accuracy for their total flux and in turn their quality. Field Generating and Field Detecting Helmholtz coils are designed as per user specifications.
-
product
Adjustable Liquid Metering Valve
ASYMTEK DV-07
The DV-07 dispenses low to medium viscosity fluids for a variety of applications from microdots to volume fill. The DV-07 valve tolerates aggressive fluid formulations including acid-based fluids, reactive adhesives such as cyanoacrylates, solvents, and fluxes.
-
product
Fluxmeters
Flux meter has been the established standard for the measurement of magnetic flux density for determining total flux in a magnet or magnetic assembly. Its use was curtailed except in a few specialized areas because of many factors such as the difficulty in setting up light beam flux meter or ballistic galvanometers, limitations on the ohmic resistance of search coils, the requirement of some degree of operator skill in reading the flux meter etc. The development of the integrating type Digital Flux meter has virtually cancelled the hitherto negative aspects of fluxmeterology and has found a broad niche for many magnetic measurement applications.