Filter Results By:
Products
Applications
Manufacturers
-
product
Digital Earth Resistance Tester, ERT-1502
Our Earth Tester is a very successful replacement of the conventional generator type hand tester. This device is most extensively used to test the earthing installation in numerous power based industries, electrical traction systems and telecommunication networks.
-
product
Earth Leakage Relay
Nippen Electrical Instruments Co.
NIPPEN's Earth Resistance Testers are used for measuring earth electrode resistance, soil resistance, earth continuity, neutral and earth loop resistance, resistance of various components etc.They are used in Railways, Defence, Utilities, Power Plants, Geological Surveys and other Industries.Direct reading type models SET/DET/TET provide direct readings of resistance on moving coil type meters, having a linear scale, 70mm long knife edge pointer and an external zero adjustment.
-
product
Earth Testers
Sanwa Electric Instrument Co., Ltd
Most facilities have grounded electrical systems, so that in the event of a lightning strike or utility overvoltage, current will find a safe path to earth. A ground electrode provides the contact between the electrical system and the earth.
-
product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
783863-02
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
product
Ground Detection and Earth Fault Location Equipment for Ungrounded or Floating DC Systems
ZX3
The ZX3 is a ground fault locator that finds grounds (current leakage) on a battery system positive rail, the negative rail, on both rails simultaneously, in a field device, battery bank or solar array/string, regardless if they are high resistance or low resistance or in a capacitive environment. It also can provide more information about the DC ground than any other equipment available, providing maximum analyzing capabilities.
-
product
Contact Resistance Meter
CRM 200B+
CRM directly measures micro-ohm values at 200A DC under live EHV switchyard conditions quickly & accurately. It is specially designed to reliably measure micro-ohm contact resistances of Circuit Breakers, Isolators, Busbar joints, earth switch joints, welded joints etc., under the hostile electrostatic noise found in live EHV switchyards up-to 765 kV. SCOPE’s ability to make electronics work in such environment enables CRM to measure mili-volts signal in the presence of kilo-volts noise.
-
product
Standard Helmholtz Coils
Helmholtz Coils are ideal for the measurement of Rare Earth (Samarium Cobalt, Neodymium) and Hard Ferrite permanent magnet materials (materials which exhibit a relative straight line demagnetization). Our standard Helmholtz Coils are for use with fluxmeters. The Helmholtz Coil measures the magnet sample as a single magnetic moment provided that the longest dimension of the magnet sample is less than one-third (1/3) the diameter of the coil system. By definition, the magnetic moment per unit volume is the intrinsic magnetization of the sample. With our calibrated Helmholtz Coil and Integrated Fluxmeter – and given the volume of the permanent magnet sample – the intrinsic open circuit operating B (Bdi) can be measured.
-
product
3 Wire (Analogue) Earth Resistance Tester
1805 ER
Standard Electric Works Co., Ltd
● High quality Taut Band movement.● Capable of measuring earth resistance and earth voltage.● 2mA measuring current permits the testing of earth resistance without tripping earth leakage current breakers in the circuit under test.● Test test leads are supplied as standard accessories for simplified two-wire measuring system.● Battery operated.● Battery check function.● Calibration performed with supplied test leads.
-
product
Earth Ground Meters
The earth tester determines ground resistance for both specific and ohm resistances. The earth tester is powered by batteries and have a clock timer function (3 minutes), Data-Hold function, a 3 ½ positions LCD display and their dimensions are 163 x 100 x 50 mm. Resistance ranges come from 20, 200 to 2000 ohms. They have a resolution of 10 / 100 mΩ / 1 Ω. The earth tester measure resistance by means of a constant reverse current (approx. 800 Hz, 2 mA). To measure ground voltage a rectifier is used (5 kΩ/V aprox. 40...500 Hz). The earth tester PKT-2630 series have a small format as well as multiple functions.
-
product
Fixed LEO/MEO Antenna Systems
Kratos Defense & Security Solutions, Inc.
Kratos Low Earth Orbit (LEO) and Medium Earth Orbit (MEO) antennas antennas are precision engineered to provide stable, high throughput links to LEO and MEO constellations. Designed to work in open air without a radome, they provide a high pointing accuracy with low backlash, controlled by Kratos’ NGC2 Controller.
-
product
NI-9205, cDAQ-9171, and cRIO-9940 USB Voltage Measurement Bundle
865683-01
NI-9205, cDAQ-9171, and cRIO-9940 USB Voltage Measurement Bundle - The USB Voltage Measurement Bundle with NI-9205, cDAQ-9171, and cRIO-9940 includes the NI-9205 C Series Voltage Input Module and the cDAQ-9171 CompactDAQ Chassis for voltage measurements. This bundle also includes the cRIO-9940 Backshell for strain relief and operator protection from high-voltage signals. The included NI-9205 features a channel-to-earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. Additionally, the NI-9205 provides up to 60 V of overvoltage protection between input channels and common, and it is rated for 1,000 Vrms transient overvoltage protection.
-
product
Earth Leakage Circuit Breakers
Mitsubishi Electric Automation, Inc
Like molded case circuit breakers, these circuit breakers are utilized to open/close low-voltage circuits and protect wiring by automatically closing circuits when they''re overloaded or if a short-circuit occurs. We offer a comprehensive range of circuit breakers that provide superior performance in electrical protection, isolation and power distribution applications. Our circuit breaker products comply with various standards such as JIS, IEC, EN, GB and UL/CSA, and with easy to install accesories, the Mitsubishi Electric circuit breakers are "user-friendly" and ensure the best solution for virtually every application.
-
product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
783864-01
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
product
Multifunction Installation Tester
COMBI519
COMBI519 carries out tests on electric systems in compliance with IEC/EN 61557-1 and therefore measurements of continuity of the protection cable, insulation resistance (with calculation of PI and DAR), overall earth resistance, RCDs type B, A and AC tripping time and current, line / fault impedance with calculation of prospective short circuit / fault current, phase sequence and conformity.
-
product
Run-Time Error Analyzer
Astrée
AbsInt Angewandte Informatik GmbH
Astre analyzes structured C programs with complex memory usages, but without recursion or dynamic memory allocation. This targets embedded applications as found in earth transportation, nuclear energy, medical instrumentation, aeronautics and space flight, in particular synchronous control/command such as electric flight control.
-
product
NI-9265, 4-Channel C Series Current Output Module
783733-01
4-Channel C Series Current Output Module - The NI‑9265 is ideal for interfacing and controlling industrial current-driven actuators at high rates. The module has built-in open-loop detection, which generates an interrupt in software when an open loop is detected as well as zeroing outputs to ensure safety and avoid driving actuators at system power on. The NI‑9265 requires an external power supply and includes a channel‑to‑earth ground double isolation barrier for safety and noise immunity.
-
product
Receiver, ICon EMI , With Protective Cover And Strain Relief
310123102
Includes all of the standard features of the iCon, in addition to Electro-Magnetic Interference (EMI) protection. An earth ground terminal is included on the and a "mate first, break last" feature connects the earth ground circuit. The earth ground terminal on the strain relief prevents user shock and injury.
-
product
6-24V DC Heavy Duty Automotive Circuit Tester
1175
Circuit tester with 1.5M of heavy duty cable and earth (crocodile) clip. Insulated contact point to prevent accidental shorting. Testing range 6-24V DC
-
product
Molded Case Circuit Breakers
Mitsubishi Electric Automation, Inc
Molded Case Circuit Breakers are utilized to open/close low-voltage circuits and protect wiring by automatically closing circuits when overloading or a short-circuit occurs. We offer a comprehensive range of standard molded case circuit breakers and molded case circuit breakers with earth leakage detection that provide superior performance in isolation and power distribution applications. Mitsubishi Electric circuit breakers offer easy to install internal and external accessories and ensure the best solution for electrical protection.
-
product
Safety Analyzer
SA-2000
The BC Biomedical SA2000 Features: AAMI Load Earth / Ground Lead Resistance Earth/Ground Leakage Current Chassis Leakage True RMS Measurements 85 to 265 VAC Operation.
-
product
Earth Ground Testers
Plant maintenance is a must! Confirming your ground resistance is crucial for instruments and machinery. Our Earth Ground Testers provide simple accurate measurement of earth resistance.
-
product
A/D Converters
Analog Devices A/D converters feature a variety of breakthrough capabilities enabling new system architectures that meet customer needs. Compact design, low power, and low cost are required by today's systems. Analog Devices offers the industry's largest range of A/D converter products that design engineers depend on for reliable performance in the harshest environments, both on Earth and in space. If you are looking for high quality and reliability while lowering cost and improving efficiency, consider using the industry's number one A/D converter products from Analog Devices.
-
product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
783863-01
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
product
Software
GPS Tracker
*Real Time display and History of all Vehicles and Personnel on Crew*Safety Reports and Legal documentation*Built around Google Earth – Data Reports free to everyone
-
product
- RS-422 and RS-485 Lightning/Surge Protector
Model 22NX
FEATURES: Triple Stage Protection; Fast Response Time For RS-422 / RS-485; Prevents Damage to Modems, Converters, and Terminals; Accommodates Data Rates to 10 MBPS; Supports 4 Circuits. The Model 22NX Lightning Sponge is designed to accommodate high-voltage transients, slow them down and redirect them to a low impedance path to earth ground.
-
product
NI-9226, 8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module
783864-02
8-Channel, 400 S/s Aggregate, 0 Ω to 4000 Ω, PT1000 RTD C Series Temperature Input Module - The NI‑9226 is a resistance temperature detector (RTD) input module. You can configure the NI‑9226 for two sample rate modes: high sample rate or high resolution. The NI‑9226 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3‑ or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per-channel current excitation. The NI‑9226 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
product
sbRIO-9215, Non-Enclosed, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Modul
780878-01
Non-Enclosed, ±10 V, 100 kS/s/ch, 16-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The sbRIO‑9215 performs differential analog input. The sbRIO‑9215 contains NIST‑traceable calibration, a channel‑to‑earth ground double isolation barrier for safety and noise immunity, and high common-mode voltage range. Non-enclosed modules are designed for OEM applications.
-
product
Inmarsat-C Physical Layer Tester
CPLT
Square Peg Communications Inc.
Square Peg Communications Inc.’s Inmarsat-C Physical Layer Tester (CPLT) is a software application that runs on the generic high-rate Physical Layer Tester (PLTH) platform. The CPLT supports testing of the physical layer performance and protocol implementations of Inmarsat-C Mobile Earth Stations (MESs) and Land Earth Stations (LESs).
-
product
Protective Bonding Testers
RMO-E Series
The RMO-E instruments are designed and ideal for testing protective bonding (grounding) of equipment following the standard IEC 61010-1. Also, they can measure the resistance of high, middle and low voltage circuit breakers, high-current bus bar joints, cable splices, and welding joints. The instruments accurately measure not only in factory environments but also in high-induction fields and substations.Both models generate a true DC ripple-free (less than 1 %) current with automatically regulated test ramps. During a test, the protective bonding testers automatically generate increasing current before measuring and decreasing current after the measurement. Consequently, this significantly decreases magnetic transients and ensures great accuracy.These instruments can store up to 500 measurements in the internal memory and have a built-in thermal printer available as an option.DV Win software communicates with the RMO-E earth resistance meter via USB or RS232 interface. It allows a user to run the test remotely from PC, as well as to download test results, analyze and generate fully configurable test reports.The RMO-E series contains two models, RMO60E and RMO100E. The main difference between these two models is in the maximal test current:60 A DC for RMO60E100 A DC for RMO100E
-
product
Multi-Channel Earth-Loss Monitor
The SURETECH Earth-Loss Monitor (ELM) measures the resistance to earth of cable armouring in such a way thatthe user can actually LOCATE the earth loss.