controlled sources of thermal radiation, used to calibrate infrared radiation devices.
-
product
Very High Temperature Calibration System
BBS-VH
The 'True' Black Body - Range 500 to 1300°C, Resolution 1°C, Accuracy <0.3% reading, Stability ±0.5°C, Aperture Ø 25 mm, Emissivity better than 0.99, Semi-Portable
-
product
Passive Imaging & Radiometers
PMMW
A low attenuation atmospheric window from 80-110 GHz (W Band) makes this band an ideal candidate for PMMW systems. Passive imagers operate by detecting naturally emitted thermal (black body) radiation from an object. Products available up to 345 GHz.
-
product
Wide Angle Scale Instrument
LS-110 LS-80 Var
Standard Electric Works Co., Ltd
● Easy to read long-scale and pointer-indications can easily be read from a distance.● Full Scale Deflection : 250°● Accuracy : Class 1.5● Scale Length : LS-110 : 183mm LS-80 : 140mm● Case and Composition : Acrylic resin cover, plastic with UL body and terminal, Four studs mounting. LS-110 case : plastic body option 1 : plastic body with metal case, no UL option 2 : metal case, no UL exception : W, VAR, PF (3P4W)● Color : White scale plate, black terminal plate, black meter body.● Pointer : Sword-type in black color.● TAUT BAND / Pivot & Jewel for LS-110.
-
product
Wide Angle Scale Instrument
LS-80
Standard Electric Works Co., Ltd
● Easy to read long-scales and pointer-indications can easily be read from a distance.● Full Scale Deflection:250°● Accuracy: Class 1.5● Scale Length :140 mm● Case and Composition: Polycarbonate window, plastic body and terminal, Four studs mounting.● Color:White scale plate, black terminal plate, black meter body.● Pointer:Sword-type in black color.
-
product
Wide Angle Scale Instrument
LS-110
Standard Electric Works Co., Ltd
● Easy to read long-scale and pointer-indications can easily be read from a distance.● Full Scale Deflection : 250°● Accuracy : Class 1.5● Scale Length : 183mm ● Case and Composition : Polycarbonate window, plastic with UL body and terminal, Four studs mounting. LS-110 case : plastic body option 1 : plastic body with metal case, no UL option 2 : metal case, no UL exception : W, VAR, PF (3P4W)● Color : White scale plate, black terminal plate, black meter body.● Pointer : Sword-type in black color.● TAUT BAND / Pivot & Jewel for LS-110.
-
product
Temperature Calibration Equipment
We offer wide line of temperature calibration equipment for calibration of contact type sensors (Baths/furnaces) and non contact type sensors (Black Bodies), available in temperature range -80°C to 1700°C.
-
product
Wide Angle Scale Instrument
LS-110 LS-80 Hz
Standard Electric Works Co., Ltd
● Easy to read long-scale and pointer-indications can easily be read from a distance.● Full Scale Deflection : 250°● Accuracy : Class 1.5● Scale Length : LS-110 : 183mm LS-80 : 140mm● Case and Composition : Acrylic resin cover, plastic with UL body and terminal, Four studs mounting. LS-110 case : plastic body option 1 : plastic body with metal case, no UL option 2 : metal case, no UL exception : W, VAR, PF (3P4W)● Color : White scale plate, black terminal plate, black meter body.● Pointer : Sword-type in black color.● TAUT BAND / Pivot & Jewel for LS-110.
-
product
Wide Angle Scale Instrument
LS-110 LS-80 PF
Standard Electric Works Co., Ltd
● Easy to read long-scale and pointer-indications can easily be read from a distance.● Full Scale Deflection : 250°● Accuracy : Class 1.5● Scale Length : LS-110 : 183mm LS-80 : 140mm● Case and Composition : Acrylic resin cover, plastic with UL body and terminal, Four studs mounting. LS-110 case : plastic body option 1 : plastic body with metal case, no UL option 2 : metal case, no UL exception : W, VAR, PF (3P4W)● Color : White scale plate, black terminal plate, black meter body.● Pointer : Sword-type in black color.● TAUT BAND / Pivot & Jewel for LS-110.
-
product
Black Body Calibration Sources
Nagman Instruments & Electronics Pvt. Ltd
Black body calibration sources by Nagman are used to calibrate infrared temperature devices that are used to measure temperature. Infrared devices can measure extreme temperatures that are very high as well as very low. They allow to measure temperature from a safe distance from the device that is heated or cooled. Calibrating the infrared temperature devices at regular intervals is very important to ensure an accurate and error free measurement. Black body calibration sources allow for an accurate calibration of the temperature devices.
-
product
Connectors, Jumper - Black
INT-10901
Jumper for 0.1" (2.54mm) spaced headers. These are also known as a 'shunt'. These mate with the 0.1" square-pin headers and are the 'open' frame style. RoHS compliant.
-
product
Whole Body EM Phantoms
EM - PHANTOM
Schmid & Partner Engineering AG
The POsable Phantom for Electromagnetic sYstems Evaluations (POPEYE) is an anatomically correct human phantom based on a torso shell w/ head with posable arms, hands and legs. This radio frequency (RF) human has been designed to meet the requirements for test configurations for which the effects of the body on the EM performance cannot be neglected, such as operating tablet and laptop computers and other body-mounted transmitters. With a simple adjustment (one tightening screw), the arms, hands and legs can be positioned accordingly for conducting simulations of any usage or operation (standing, sitting, arms raised, talking position, etc...).
-
product
Sensor Bodies
The armature - assembled sensor body - is the central component of an inline photometer. We have already designed more than 1000 different sensor bodies and more than 50 types are always on stock. All optek inline sensor bodies are made from high quality materials and are machined with extreme precision. The quality-tested manufacturing tolerances allow optical path lengths of up to 1000 mm, for which the accuracy of the incoming and outgoing light beam is ensured by testing a laser-based coaxiality tolerance test to the reference axis. To cover a wide spectrum of different process conditions, optek sensor bodies can be manufactured from various materials (also for aggressive chemicals or with NACE MR 0175) and adapted with regards to:
-
product
Zinc Diecast Body Vacuum Switch
P119V
The P119V Zinc Diecast Body Vacuum Switches are the inexpensive version of the P117V and recommended for indoor OEM use. It is commonly used in the medical field and as a safety switch in numerous applications. The compact nature of these switches make them ideal for tight spaces.
-
product
Adaptative Body Bias (ABB) IP
A revolutionary FD-SOI bias generator enabling real-time corner compensation:- Up to 10x energy efficiency gains at low VDD- Foundation IP independent- Seamless integration
-
product
SS Body Pressure Switch (longbody, NEMA 4)
P117LG
The P117LG NEMA 4 Stainless Steel Pressure Switches are the weather-proof, liquid-resistant version of the P117G. The NEMA 4 rating makes these rugged switches suitable for outside applications or in areas of condensing humidity. Unlike the P117G, the P117LG set point is factory set to customer specification and is non-adjustable.
-
product
Body Scanners
3D human body scanners obtain 3D images and models in seconds, making this an ideal solution for full body digitizing and human body modeling.
-
product
Body Neasurement App.
MySizeID
MySizeID offers shoppers the best online shopping experience. All a shopper need is a smartphone and MySizeID does the rest! Shopping for apparel online can be frustrating, but when shoppers know their RIGHT size, they can be confident that they are purchasing items that will fit them accurately, leading to increased loyalty and fewer returns. MySizeID uses patented technology and unique algorithms to capture a person’s measurements using smartphone sensors, without the need to use a camera. For more information about MySize patented technology contact us via email: contact@mysizeid.com
-
product
Signal Patchcord, ITA, 36", QuadraPaddle, 24 AWG Black Teflon, Single Ended
7-121024000-036
Signal Patchcord, ITA, 36", QuadraPaddle, 24 AWG Black Teflon, Single Ended.
-
product
Cover Plate, ICon, For Mounting Panel Cutouts, Painted Black
310113490
The cover plate is used to fill unused positions in the iCon Fixed Mounting Panels (310 113 486 & 310 113 488).
-
product
SPECTRA Black
CA4901
SPECTRA Black is a full featured wideband surveillance system packaged in a compact, deployable suitcase.
-
product
Fixed Mounting Panel, iCon, 4U, 8 Positions, Black Anodized
310113302
This 4U Fixed Mounting Panel has 8 vertical positions. The iCon cover plate is sold separately (310113467). The spacing of the positions will accommodate ITA P/N's 410123102, and 410123232. Also available in a painted gray finish - P/N 310113301.
-
product
Soft Carrying Case, 4-5/7 In. D, Black
U1175A
Soft carrying case for U1200 series clamp meters; 4-5/7 in, black
-
product
Slim Body Automatic Sensitivity Setting Photoelectric Sensor
SU-7/SH
Panasonic Industrial Devices Sales Company of America
Slim Body Automatic Sensitivity Setting Photoelectric Sensor
-
product
Body Temperature Monitoring System
TEMPMED
TEMPMED is a non-contact body temperature measurement system fully compliant with IEC 80601-2-59:2019 Standard
-
product
IEC60335 Temperature Black Test Corner
CX-W16
Shenzhen Chuangxin Instruments Co., Ltd.
Temperature Test Corner conform to IEC60335-1:2004 and GB4706.1-2005 can be used to the temperature test of all kinds of electronic products supply, in conformity with the standards requirement of the environmental conditions.
-
product
Single Front Slot Universal Low-Profile PCI to PCMCIA Adapter, Black Bezel
P313B
To cater to the latest generation of low-profile PCs that can only use low-profile PCI add-in boards, Elan has created the P313. This model, from the P-series range, features a PCMCIA Type III 3.5" drive bay mounted slot and a circuit board that conforms to the MD1 profile specification. It will allow you to use any TypeI/II/III PCMCIA card.
-
product
Human Body Temperature Measuring Thermal Camera
Zhejiang ULIRvisionTechnology Co., LTD
The infrared thermal imaging camera detects the infrared radiation emitted by human body and forms an image of the surface temperature distribution. The higher the temperature of the object, the greater the infrared radiation energy will be. The thermal imager obtains the temperature distribution on the surface of the human body through the received infrared energy. The following are our featured human body temperature measuring thermal camera.