Product
CASS Instrument Real Time Controller
-
External control of the Navy CASS ATE via Ethernet. Standardized graphical user interface (GUI) for individual control of each instrument independent of CASS software. Allows TPS developer or ATE maintainer to change/control instrument settings for TPS debug and instrument troubleshooting.
-
Product
PXI 2 Amp Multiplexer, Single 8-Channel, 4-Pole
40-635A-103
Multiplexer Module
The 40-635A-103 is a single 8-channel, 4-pole MUX and is part of a range of Multiplexer modules available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC. The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
Generic RF ATE Test
-
The Generic RF ATE is developed to test the Radar and Radar Subsystems. The ATE is primarily built using an instrumentation control, precision RF routing systems and rack mounted test instruments. Generic RF ATE system enables measurement of parameters of Radar equipment such as Local Oscillators, Waveform Generators, Up and Down Converters, Analog Receivers, Array Group Receiver Units, TR Modules. The ATE is configured to test the Radars upto 18GHz frequency range.
-
Product
PXI Single 32x8 Matrix, 2 Pole Switching
40-531-022
Matrix Switch Module
Model 40-531 very high density matrix modules are configured as a 32x8, while the 40-532 modules are configured as a Dual 16x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules. For example, seven PXI modules will form a 224x8 Matrix, a total of 1792 crosspoints in a 7-slot PXI Chassis.
-
Product
PXI Single 44x4 Matrix, 2 Pole Switching
40-523-022
Matrix Switch Module
Medium density PXI dual 44x4, 2-pole matrix - it is also available in reed relay formats of 1-pole and 1-pole screened (see "also in this range" on right). The screened version is suitable for switching signals up to 50MHz. Typical applications include signal routing in ATE and data acquisition systems. The two banks may be used for operating a 4-wire measurement system (bank-1 for source, bank-2 for measure). Larger matrices may be constructed by daisy chaining the common signals from multiple PXI Modules.
-
Product
SLSC and CRIO Modules and Accessories
Module
Our approach to delivering a high-quality Aerospace, Automated Test Equipment (ATE) asset begins with leveraging National Instruments hardware and software standard platforms. Beginning with high quality instrument platforms for standard Input and Output (I/O), we leverage NI’s PXI and Compact RIO platforms. Extending these system is NI’s unique platform for Switching, Loads and Signal Conditioning (SLSC), which allow the standard I/O to be customized for high performance aerospace industry applications.
-
Product
Power Module Tester
-
The Power Module Checkout ATE is developed for testing DC-DC Power modules typically utilized in India's space program. The DC-DC converters are exhaustively tested for all design parameters including supply voltage range, line and load regulation, efficiency, ripple, noise, transient response and so on. Special power sources and loading mechanisms are deployed to enable testing of various types of power modules.
-
Product
LXI High Density 384x4 2-Pole 2A Matrix With BIRST
60-556-026
Matrix Switch Module
High density double pole matrix capable of switching up to 300VDC/250VAC, or 2A (60W max). The use of high quality electro-mechanical relays offer high switching confidence and make it suitable for signal routing in large ATE systems.
-
Product
Dual 12x4 1-Pole High-Density PXI Matrix Module
40-520-405
Matrix Switch Module
The 40-520 family of high-density PXI matrices is available in 22 different configurations with up to 256 crosspoints. The choice of six bus widths (x16, x12, x8, x6, x4 and x2) enables competitively priced solutions using Pickering Electronics instrumentation quality reed relays. These relays offer very long life with good low-level switching performance and excellent contact resistance stability. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
Single 8x12 1-Pole High-Density PXI Matrix Module
40-520-103
Matrix Switch Module
The 40-520 family of high-density PXI matrices is available in 22 different configurations with up to 256 crosspoints. The choice of six bus widths (x16, x12, x8, x6, x4 and x2) enables competitively priced solutions using Pickering Electronics instrumentation quality reed relays. These relays offer very long life with good low-level switching performance and excellent contact resistance stability. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
ATE For ADC Module
MS 1527
-
The Semi-ATE is used for testing the analog ADC. It shall carry out the functional test on ADC analog module. The ATE shall have all necessary IO signals on the connector end. The semi-ATE can carry out the functional tests on ADC analog module with host PC or laptop. It provides +15V, -15V, +5V & -5V to module and +2.5V high precision reference voltage. It can able to control keysight N6700B Power supply mainframe using RS422 interface.
-
Product
PXI 8 Slot BRIC 88x8 1-Pole (4 sub-cards)
40-562A-121-88X8
Matrix Switch Module
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8-slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
Product
PXI 8 Slot BRIC 15x32 1-Pole (3 sub-cards)
40-562A-121-15X32
Matrix Switch Module
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8-slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
Product
LXI High Density 384x8 2-Pole 2A Matrix With BIRST
60-555-026
Matrix Switch Module
High density double pole matrix capable of switching up to 300VDC/250VAC, or 2A (60W max). The use of high quality electro-mechanical relays offer high switching confidence and make it suitable for signal routing in large ATE systems.
-
Product
PCB Test Fixtures
-
ATE, ICT, semiautomatic & manual electronic test fixtures, PCB test fixtures, cable test fixture, wiring harness test fixtures, dedicated test fixtures, functional test fixtures, electronic test fixture programming. PADS Schematic capture, circuit board layout, PCB design prototype, solder paste stencils, X-Y coordinate data, B.O.M. maintenance, and manufacturing documentation, Gerber data.
-
Product
PXI 2A Multiplexer, 4-Bank, 16-Channel 2-Pole
40-614-007
Multiplexer Module
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
Product
PXI 8 Slot BRIC 176x8 2-pole (8 sub-cards)
40-562A-122-176X8
Matrix Switch Module
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8-slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
Product
PXI 20x4 Power Matrix 2A 1Pole
40-548-001
Matrix Switch Module
Model 40-548-001 is a high density single 1-pole 20x4 power matrix module. It is also available in single 10x4, dual 10x4 or single 10x8 relay formats: Typical applications include power routing in Functional ATE systems, specifically automotive electronics, for example testing of Engine Management Units.
-
Product
PXI 8 Slot BRIC 44x16 1-Pole (4 sub-cards)
40-562A-121-44X16
Matrix Switch Module
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8-slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
Product
PXI 2 Amp Multiplexer, Dual 8-Channel, 4-Pole
40-635A-007
Multiplexer Module
The 40-635A-007 is a dual 8-channel, 4-pole MUX and is part of a range of Multiplexer modules available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC. The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
PXI 8 Slot BRIC 352x4 1-Pole (8 sub-cards)
40-562A-121-352X4
Matrix Switch Module
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8-slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
Product
PXI High Density Multiplexer, 2-Bank, 40-Channel, 2-Pole
40-615A-010
Multiplexer Module
The 40-615A-010 is a 2-bank, 40-channel, 2-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. These feature a wide range of switching configurations and are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector.
-
Product
PXI-2595, 5 GHz, 50 Ω, 4x1 PXI RF Multiplexer Switch Module
778572-95
Multiplexer Module
5 GHz, 50 Ω, 4x1 PXI RF Multiplexer Switch Module—The PXI‑2595 is ideal for applications that require the routing of high-frequency signals inside automated test equipment (ATE) systems because it can switch signals with very low insertion loss. The module also features excellent insertion loss, voltage standing wave ratio (VSWR), and isolation parameters to minimize signal degradation. You can use the onboard relay count tracking feature to predict relay lifetime and reduce unexpected system downtime.
-
Product
PXI Multiplexer Single 48 Ch 1 Pole
40-632-021-48/1
Multiplexer Module
This series of general purpose multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 68-pin connector. Available reed relay formats are 1-pole, 2-pole and 1-pole screened.
-
Product
PXI High Density Multiplexer, 1-Bank, 160-Channel, 1-Pole
40-615A-011
Multiplexer Module
The 40-615A-011 is a 1-bank, 160-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. These feature a wide range of switching configurations and are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Connections are made via a front panel 200-pin connector.
-
Product
Advanced Power System: Dynamic DC Power Supply, 60 V, 33 A, 2000 W
N7973A
DC Power Supply
The N7973A is designed for automated test equipment (ATE) applications where high-speed dynamic sourcing and measurement is needed.
-
Product
PXI 8 Slot BRIC 88x8 2-pole (4 sub-cards)
40-562A-122-88X8
Matrix Switch Module
This version of our BRIC is part of a range of high-density PXI matrix modules. These modules are available in 2, 4 or 8-slot PXI sizes to suit all high performance matrix requirements and are constructed using instrumentation quality reed relays. With this high level of switching density, these PXI matrix modules allow a complete Functional ATE system to be housed in a single 3U PXI chassis. These BRIC matrix modules allow the use of lower cost 8 or 14-slot PXI chassis.
-
Product
PXI High Density Multiplexer, 47-Channel, 2-Pole
40-640A-022-47/2
Multiplexer Module
The 40-640A-022-47/2 is a 47-channel, 2-pole MUX and is part of a series of high density multiplexer modules featuring a choice of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
LXI HighDensity 224x16 2A Matrix with BIRST
60-554-027
Matrix Switch Module