Data Generators
Create and output test data.
-
Product
Alternate 2.64 (75.00) - 6.50 (184.00) General Purpose Probe
EPA-2E-1
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Data Acquisition Module for Embedded Systems with IO60 expansion
IO60-M410
Data Acquisition Module
WINSYSTEMS’ IO60-M410 is a reliable data acquisition module for embedded systems with IO60 expansion featuring 24 GPIO (General Purpose Input-Output) tolerant to 30 V DC. Activity LEDs indicate device communication and DAC fault. WINSYSTEMS can provide custom configurations for OEM clients. Please contact a Applications Engineer through our contact page for details.
-
Product
Signal Generator Adapter Module For FlexRIO
Signal Generator
Signal Generator Adapter Modules for FlexRIO feature either high or low‐speed analog output and can be paired with a PXI FPGA Module for FlexRIO or the Controller for FlexRIO for custom signal generation. Whether you need to dynamically generate waveforms on the FPGA or stream them across the PXI backplane, these adapter modules are well suited for applications in communications, hardware‐in‐the‐loop (HIL) test, and scientific instrumentation.
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3B
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 2.00 (57.00) - 3.60 (102.00) General Purpose Probe
P2664G-4V1S
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 10Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 114Full Travel (mm): 2.90Recommended Travel (mil): 84Recommended Travel (mm): 2.13Overall Length (mil): 895Overall Length (mm): 22.73Overall Length Remark: Tip 1C: 845 mil (21.46 mm) Tip 2R: 935 mil (23.75 mm)
-
Product
Pyramid, 3-Sided Chisel 30°, Alternate 0.78 (22.00) - 3.70 (105.00) General Purpose Probe
HPA-0T-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
16-CH 16-Bit 250 KS/s Simultaneous Sampling DAQ Cards
PXI-2022
Data Acquisition Module
ADLINK"s PXI-2022 is a simultaneous-sampling multi-function DAQ card to meet a wide range of application requirements for PXI bus computers. The device can simultaneously sample 16 AI channels with differential input configurations in order to achieve maximum noise elimination.
-
Product
8-CH Analog Input Module
ND-6017
Data Acquisition Module
ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.
-
Product
Clock Generator Module
M8008A
Clock Generator
The M8008A is designed as sample clock source for the M8199A 128/256 GSa/s Arbitrary Waveform Generator. It can also be used as a standalone low-jitter clock source for other applications. It comes as a 1-slot AXIe module, which allows the M8008A plus up to two M8199A AWG modules to be plugged into a single 5-slot AXIe chassis.
-
Product
Standard 1.50 (42.00) - 3.30 (94.00) General Purpose Probe
P2663G-1V1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 810Overall Length (mm): 20.57
-
Product
30MHZ, 150 MS/s,16 kpts, 2 Channel, 20 Vpp Function/Arbitrary Waveform Generator
T3AFG30
Arbitrary Waveform Generator
Teledyne Test Tools T3AFG5 and T3AFG10 series Function/Arbitrary Waveform Generators are a new family of low cost, high performance, single channel Function / Arbitrary waveform generators offering a high level of functionality and an excellent specification at a very competitive price point.
-
Product
2.5GS/s 16Bit 2GS Mem 8CH 16 Markers AWG
P2588D
Waveform Generator
The Proteus P2588D, is a 2.5GS/s, eight channel arbitrary waveform generator packaged in a 4U, half 19” dedicated chassis, offering technologically advanced options and configurations that integrate the ability to transmit, receive and perform digital signal processing all in a single instrument. The P2588D offers industry leading performance Including an innovative task oriented programming, real time data streaming, fast feedback loop for environment dependent waveform generation and user customizable FPGA for application specific solutions.
-
Product
Standard 1.10 (31.00) - 3.85 (109.00)General Purpose Probe
SPA-64-8
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 50Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 375Overall Length (mm): 9.53Overall Length Remark: Exact length depends on selected tip: Tip 1,4, 7: 0,375″; Tip 2,3: 0,365″; Tip 8: 0,385″; Tip ,9,10: 0,363″
-
Product
PXI-5422, 80 MHz Bandwidth, 16-Bit PXI Waveform Generator
779087-03
Waveform Generator
80 MHz Bandwidth, 16-Bit PXI Waveform Generator - The PXI‑5422 is a 80 MHz arbitrary waveform generator capable of generating user-defined, arbitrary waveforms and standard functions including sine, square, triangle, and ramp. This arbitrary waveform generator can generate signals from -6 V to +6 V and uses direct digital synthesis (DDS) to precisely generate waveforms. The PXI‑5422 also features advanced synchronization and data streaming capabilities.
-
Product
C-S General Purpose Probes
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 45Full Travel (mm): 1.14Recommended Travel (mil): 30Recommended Travel (mm): 0.76Overall Length (mil): 395Overall Length (mm): 10.03Rec. Mounting Hole Size (mil): 46.5Rec. Mounting Hole Size (mm): 1.18Recommended Drill Size: 56
-
Product
PCI-5421, 100 MS/s, 16-Bit Waveform Generator Device
778692-01
Waveform Generator
The PCI‑5421 can generate user-defined, arbitrary waveforms and standard functions, including sine, square, triangle, and ramp. This arbitrary waveform generator can generate signals from -6 V to +6 V and uses direct digital synthesis (DDS) to precisely generate waveforms. The PCI‑5421 also features advanced synchronization and data streaming capabilities.
-
Product
14-Bit AWQ, 2 GSPS Waveform Generator
SDR14TX
Waveform Generator
The SDR14TX is a dual-channel flexible arbitrary waveform generator (AWG). It offers an outstanding combination of high bandwidth and dynamic range which enables generation of wideband signals.
-
Product
Keysight 32-Channel FormC/Form A General Purpose Switch for 34980A
34937A
General Purpose Switch
The Keysight 34937A is a general-purpose switch module for the 34980A Multifunction Switch/Measure Unit. It has 28 independent single-pole, double-throw (SPDT) 1A relays and 4 single-pole, single-throw (Form A) 5A relays. This module is used to cycle power to products under test, control indicator and status lights, and to actuate external power relays and solenoids. The Form C channels are 300V, 1A contacts and can handle up to 60W, and the Form A channels are 30VDC/250VAC, 5A contacts and can handle up to 150W. Standard 50-pin Dsub connectors allow for use with standard cables, terminal blocks, or mass interconnect solutions.
-
Product
6GHz Dual Channel Signal Generator
LS6082B
Signal Generator
The LS6082B is a 6GHz Dual Channel RF Analog Signal Generator, offers industry leading performance, in an easy to use benchtop box. It features exceptionally fast switching speed, superior signal integrity and purity and all the necessary modulated signals for analog communication systems. The design offers excellent performance and abilities combined with an affordable price tag, needed from the R&D benches to the production lines.
-
Product
RMP Replaceable General Purpose Probes
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 125Test Center (mil): 20Test Center (mm): 0.51Full Travel (mil): 79Full Travel (mm): 2.01Recommended Travel (mil): 52Recommended Travel (mm): 1.33Mechanical Life (no of cyles): 50,000Overall Length (mil): 598Overall Length (mm): 15.19
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T65
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
32-CH 16-Bit Up to 250 kS/s Multi-Function DAQ Cards
PCI-9114 Series
Data Acquisition Module
ADLINK PCI-9114 series are 32-CH, 16-bit, high resolution multi-function DAQ Cards. The PCI-9114 device features flexible configurations on analog input. The devices are divided into 2 kinds: normal gain version and high gain version. Both versions provide 4 programmable input ranges for bipolar and unipolar inputs. The A/D on the PCI-9114DG device features a sampling rate of 100 kS/s with resolution at 16 bits, while PCI-9114A-DG/HG device features a sampling rate of up to 250kS/s with resolution at 16 bits. The device supports automatic analog input scanning, and offers a differential mode for 8-CH analog inputs and maximum noise elimination, as well as single-ended modes for 16- CH analog inputs. The PCI-9114 also features 1-CH 16-bit general purpose timer/counter, 16-CH TTL isolated digital inputs and 16-CH TTL isolated digital outputs. ADLINK PCI-9114 delivers cost-effective and reliable data acquisition capabilities and is ideal for a broad variety of applications.
-
Product
Arbitrary Waveform Function Generator PXI Card
GX1110
Waveform Generator
The GX1110 is a high performance, single-channel PXI arbitrary waveform generator that offers function generator and arbitrary waveform generator functionality within one instrument. Built-in waveforms are available for use with both the DDS or AWG modes of operation and include Sine, Triangle, Ramp, Noise, Gaussian pulse and Sinx / x. A flexible sequencer is also available as part of the AWG's architecture, supporting the generation of complex waveforms.
-
Product
Ultra High 6.70 (190.00) - 11.80 (335.00) General Purpose Probe
EPA-4B-2
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
Alternate 2.64 (75.00) - 6.50 (184.00) General Purpose Probe
EPA-2G40-1
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3A
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
50MS/s Dual-Channel Arbitrary Waveform Generator
WW5062
Waveform Generator
Model WW5062 represents the next generation of products in the field of function, pulse and arbitrary waveform generators. This instrument is superior and far more versatile than any existing equivalent whether it is an analog or digital product. As a waveform source, this model can replace analog generators in almost every application.
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2G40
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
PXIe-5442, 43 MHz Bandwidth, 16-Bit Onboard Signal Processing, 512 MB, PXI Waveform Generator
780109-03
Waveform Generator
PXIe, 43 MHz Bandwidth, 16-Bit Onboard Signal Processing, 512 MB, PXI Waveform Generator—The PXIe‑5442 is a 43 MHz arbitrary waveform generator capable of generating user-defined, arbitrary waveforms, standard functions including sine, square, triangle, and ramp, as well as signals that require onboard signal processing. Some of these signal processing operations include FIR and CIC interpolation filters, digtal prefilter gain, numerically-controlled oscillator, and I/Q mixing for quadrature digital upcoversion. The PXIe‑5442 also features advanced synchronization and data streaming capabilities.
-
Product
PXI Data Acquisition
DAQ
Data Acquisition Module
Installation and configuration is fast and easy with standard connectors, soft front panels and Keysight connection expert. In addition, software drivers support the most common programming environments such as Visual Studio®, C, C++, Visual Basic, MATLAB® and LabVIEW™.





























