-
Product
Calibration Services
-
for Humidity, Dew Point, Trace Moisture and Temperature Measurement Instruments
-
Product
RF Calibration Equipment
-
Bird’s legacy in RF calibration runs deep—dating back to our early days supplying calorimeters for high-power applications. Today, that expertise lives on in our advanced calibration equipment, trusted by labs, manufacturers, and service providers around the world.
-
Product
Portable Calibration Shaker Table
AT-2030
-
The AT-2030 portable calibration shaker table is designed for simple accelerometer and vibration transducer calibration without the need for advanced features. AT-2030 shaker table and vibration calibrator is a variable frequency, variable amplitude, battery operated portable shaker capable of calibrating accelerometers, transducers, and proximity probes. Applications are producing a known vibration signal in g’s, mils, or ips for sensor, wiring, instrumentation, and system checkout in vibration condition monitoring applications.
-
Product
Calibration & Repair Services for Instruments in Process Control
-
Meeting customer needs is our number one priority. Hastings Instruments offers free technical support as well as personalized one-on-one customer service through a diverse organization of field Customer Service Representatives and Distributors. We have more than 50 field Customer Service Representatives that are situated to provide local support throughout the world.Additionally, reaching our Customer Service Department is only a toll-free number away (USA) and is available for your convenience. Faxing or E-mailing your question first will assure that it is reviewed before you speak to a Customer Service Representative. Also, following the steps listed in our trouble shooting guides (included in each product instruction manual) may help direct you to the appropriate department before you pick up the phone to call.
-
Product
Barcode Conformance Calibration Standards
-
Barcode symbol quality has been at the forefront of discussion among practitioners in the automatic identification and data capture (AIDC) industry since they were invented in 1951. Barcodes became commercially successful when they were used to automate checkout systems at grocery stores, with the very first scanning of the Universal Product Code (UPC) on a pack of Wrigley Company chewing gum in June 1974. The Uniform Code Council (UCC) published barcode quality guidelines, and ANSI X3.182-1990 became the first published standard for barcode quality. Since then, ISO/IEC 15416 for 1D symbols and ISO/IEC 15415 for 2D symbols have become the global standards for grading printed barcodes.
-
Product
AC Calibration Standard
1U647-001
-
The 1U647-001 is a low cost calibration standard used to determine if a 1U632-100 or a 1U663-100 DMU requires factory calibration. Its portability makes it ideal for field-testing. The standard generates signals that simulate the aircraft’s resolvers, rotary variable transformers (RVTs), and linear variable displacement transformers (LVDTs). The unit also generates a pulse width modulated (PWM) signal, and routes the output of an ARINC 429 source to the different DMU input channels. The calibration standard connects directly to the DMU and replaces the output signals of an active extender card. Discrete switch settings simplify testing. The unit is housed in a rugged aluminum case.
-
Product
Three-Phase Electric Power/Energy Calibrator
MC133Ci
-
The MC133Ci model is a compact one-housing three phase electric power/energy calibrator. It can supply the device under test with one phase accurate AC voltage and current with calibrated phase shift or DC voltage and current. Output voltage can be set in five ranges up to 280V and output current in six ranges up to 30A.
-
Product
Acoustic System
Constellation
-
In acoustics, one size does not fit all. Constellation offers an elegantly simple way for venues to transform architectural acoustics with a finger tap, affording a level of sonic flexibility never before possible.
-
Product
Humidity Calibration Set
-
The humidity transmitters as all other measuring instrumentsshall be periodically checked and eventually adjusted. The most simple solution for this purpose is the E+E calibrationset.
-
Product
CrystalCalHP Calibration System
-
AMETEK Sensors, Test & Calibration
This portable gauge and transmitter calibration system is 7 to 10 times faster than a deadweight tester. It allows you to do a 10 point up and down calibration in less than 3 minutes including printing out a calibration certificate.
-
Product
Calibration Kit
N611
-
*N611 Calibration Kit, * Frequency Range: up to 6 GHz, * Impedance: 50 Ohm. * Connector Type: N-type.
-
Product
Transducer Calibration
m+p SensCal
-
Regular transducer calibration is an essential requirement for maintaining the accuracy, reliability and repeatability of the results obtained from a measurement system. m+p international’s m+p SensCal program provides a quick and simple process for calibrating accelerometers (piezo-electric with charge output or IEPE, piezo-resistive, capacitive) in your laboratory, as well as velocity or displacement transducers.
-
Product
Electrical Calibration
-
Trescal provides full Electrical Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Electrical Calibration services can be delivered at your site or at our lab. Accreditations for our electrical calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
Product
IR Calibration Instruments
-
Bodkin Design & Engineering, llc
We offer a line of comprehensive solutions to address all of your thermal calibration needs. From bench-top differential sources with .01° C resolution for experiment calibration to built-in OEM devices for on-the-fly thermal reference, Bodkin Design and Engineering and IRBlackbody have the right blackbody for you.
-
Product
Combined Acoustic Release and Underwater Modem
SR-9100
-
Smart Modem Acoustic Release Technology (SMART) Release is a unique concept from Teledyne Benthos, that combines the proven technology of an underwater acoustic release with the reliable undersea communications functionality of an acoustic modem.
-
Product
Acceleration Pickup Calibrator
VX-1100A
-
VX-1100 is for a piezoelectric type accelerometer which is widely used for measuring vibration. This compact calibrator is effective for checking operation(sensitivity) sensors before measurement to acquire accurate data.Built-in sensor amplifier and display in one unit allows direct reading of the sensitivity. This calibrator excites the sensor at a frequency of 159 Hz and acceleration of 10 m/s2 rms, and the sensor outputs can be used as calibration signals for a vibration measuring system.
-
Product
Acoustic Measurement Systems
-
Even AuSIM's audio simulation is only as good as the model parameters within the simulation. For AuSIM, deriving optimal model parameters begins with studying the acoustic world around us. The AuSIM3Dtm display systems synthesize a virtual aural environment from parameters based on the physical world. But the same techniques can be applied to reverse the process and extract parameters from the physical world to use for later synthesis.
-
Product
Micro-Ohmmeter Calibration Kit
LOM-530
-
The LOM-530 is convenient single unit containing a complete set of (5) working standard grade resistors for complete calibration of micro-ohmmeters. The standard resistance values are those used by the LOM-510A Microohmmeter/Milliohmmeter.
-
Product
Transducer Calibrator Systems
-
Unholtz-Dickie Transducer Calibration Systems have earned their place in industry as the standard for calibrating accelerometers and velocity transducers. The Model 680C is UD's latest generation of an automated transducer calibration system, utilizing the expanded features of the i5 based APEX SL-C Windows vibration control system.
-
Product
Relative Humidity Calibration Services
-
PST have calibration laboratories offering Relative Humidity calibrations in six locations across the globe.
-
Product
Zero Gas Generator - Calibration of Ambient Air Monitoring Systems
ZNV-7
-
HORIBA Europe’s Zero Gas Generator ZNV-7 has been developed to check the zero point and dilute the span gas sources in order to carry out the calibration of ambient air monitoring systems. The increasing sensitivity of ambient air analyzers is required by strict official guidelines, which demands pure and dry air in a sufficient quantity at constant pressure.
-
Product
Multifunction Voltage and Current Calibrator
MC140i
-
Multifunction calibrator MC140i is ideal for calibration of voltmeters, ammeters, DMMs and panel meters. AC/DC voltage 1uV to 1000V. Current 50uA? to 1000A using test coil. Deviation control along readout. 0.0035% basic dc accuracy. 0.03% basic ac accuracy. Supplied with RS232 interfaces. UKAS/NIST Traceable
-
Product
Calibrators
-
Our high accuracy calibrators work with all competitor products and offers the customer a way to maintain their equipment, while keeping the specifications of their process.
-
Product
Full-spectrum Acoustic Logger
AudioMoth
-
AudioMoth is a low-cost, full-spectrum acoustic logger, based on the Gecko processor range from Silicon Labs. Just like its namesake the moth, AudioMoth can listen at audible frequencies, well into ultrasonic frequencies. It is capable of recording uncompressed audio to microSD card at rates from 8,000 to 384,000 samples per second.
-
Product
Calibrators
-
Electronic Development Labs, Inc.
Your equipment and sensors must function at optimal levels to achieve the results you want—no matter your industry. Engineered by skilled craftsmen to maximum reliability accuracy, EDL calibrators are trusted around the globe—and have been for decades. Your business relies on predictable results that consistently meet quality standards. And EDL has set the standard for calibration.
-
Product
Calibration Segment Arm
-
A torque analyzer or a torque sensor are a finely tuned instrument designed for testing and monitoring torque applications. In order to maintain accuracy, it is crucial that torque measuring equipment be properly calibrated regularly. Segment arm is engineered for calibrating torque analyzers and sensors and ensuring instruments are traceable to National or International Standards, such as N.I.S.T and ISO.
-
Product
Instrument Transformer Calibrators
CTPT 81
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Tests: Ratio error. Excitation current and curve. Polarity CT / PT TESTER
-
Product
ECPR System (Electrically Calibrated Pyroelectric Radiometer)
Rs-5900
-
Developed in conjunction with NIST, the Rs-5900 ECPR is a ±1% absolute accuracy radiometric transfer standard for the visible to near-IR (0.25-2.0µm), with the RsIR Option extending the ±1% accuracy to >20µm. The RsP-590 Pyroelectric Probe requires no cooling and maintains ±1% accuracy from 1 µW to 100 mW. The ECPR uses an auto-nulling, electrical substitution technique that allows the instrument to be referenced against NIST electrical standards, insuring maximum accuracy and precision. Unlike most electrically calibrated radiometers, there is a direct correlation between electrical and optical heating because the same material serves as both the optical absorber and electrical heating element.
-
Product
Three Phase Portable Energy Meter Calibration Equipment
GF302D1
-
Beijing GFUVE Electronics Co.,Ltd.
The GF302D1 three phase portable energy meter test system consists of an integrated three phase current and voltage source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7" touch LCD-display.
-
Product
VNA Calibration Kits
-
Vector Network Analyzers are commonly used to accurately determine the RF Characteristics of microwave components. Accurate Testing of microwave circuits means eliminating measurement errors and ensuring repeatable results. This is only possible when the network analyzers can be calibrated with known and true calibration standards.





























