-
Product
Acoustic and Aydio Analyzer
XL2
-
The hand-held XL2 Analyzer is a powerful Sound Level Meter, a professional Acoustic Analyzer and a precision Audio Analyzer in one instrument. Easy operation and countless applications distinguish this quality Swiss product.
-
Product
Palm Size Digital Multimeter, Calibrated, 1999 Count, Mean Value, Manual Range, 3.5 Digit
72-7770 CAL
-
The 72-7770 CAL from Tenma is a palm sized digital multimeter with 3 3/4 digit LCD. It is 3 1/2digits with steady operations, fashionable design and highly reliable hand held measuring instrument. The meter measures AC/DC voltage, AC/DC current, resistance, temperature, diode and continuity. It is an ideal tool for maintenance. The multimeter features square wave output, data hold, low battery indicator and display backlight, This meter complies with the standards CE, IEC61010, in pollution degree 2, overvoltage category (CAT I 600V, CAT II 300V) and double insulation.
-
Product
Universal Solution for Model-based Calibration Software
INCA
-
INCA tools are used for ECU development and test as well as for validation and calibration of electronically controlled systems in the vehicle, on the test bench, or in a virtual environment on the PC. The tools are used worldwide in over 20,000 installations in development and production projects.
-
Product
Calibrator, Calibrated w/Data, Current, 185 mm, 78 mm, 38 mm
72-6694 CAL D
-
The 72-6694 CAL D from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).
-
Product
Air Data Calibration
-
Fluke calibration offers digital pressure monitors, air data calibrators and laboratory standards for air data pressure range calibrations. Each of these systems feature pressure ranges, measurement units and features specific to calibrate air data test sets and RVSM compliant air data instruments. Models include 2468 Ruska and ADCS-601 DHI primary level standards; 7750i Ruska air data controller/calibrator and RPM4-AD DHI reference pressure monitor.
-
Product
N-port Calibrated Measurements
S97551B
-
The S97551B software enables full multiport error correction and measurement capabilities when using multiple USB vector network analyzers
-
Product
Partial Discharge Measurement Calibrator
DAC-CP-2
-
DAC-CP-2 is a calibrator for partial discharge measurements. The electric charge enables to generate up to max 10000pC. It is battery-operated and can be charged by connecting to the measuring instrument (DAC-PD-3).
-
Product
Calibrator, Calibrated w/D & U, Current, 185 mm, 78 mm, 38 mm
72-6694 CAL DU
-
The 72-6694 CAL DU from Tenma is a current calibrator. It provides quality and accuracy of handheld calibrator of precision current source. It features large LCD display (maximum display counts 1999, 13mm (0.5") digit size). The current calibrator has 006P DC 9V, MN1604/PP3 battery or equivalent alkaline type or heavy duty type power supply. The dimension is 185mm × 78mm × 38mm (7.3" × 3" × 1.5") and weight is 265g/0.58lb (including battery). It has adjustable 0 to 24mA current source, 2 ranges (0 to 19.99mA (0.01mA display resolution, ±(0.25% FS + 1d) accuracy), 0 to 24mA (0.1mA display resolution, ±(0.5% FS + 1d) accuracy).
-
Product
RF Calibration Accessories
-
Employing good connector practice when using an RF calibrator not only avoids measurement errors and minimizes connector repeatability uncertainties but also reduces risk of damage to connectors and equipment. The 96000CONN and 9600CONN connector kits include a range of adapters and torque wrenches intended for use with the 96000 Series RF Reference Sources (9600CONN for the 96040A and 96000CONN for the 96270).The 9600CONN connector kit includes one each of 50 Ω and 75 N-Type male-female adapter for use with the 96000 Series levelling head as a “connector saver” or “sacrificial connector” to avoid risk of damage when making connections to UUT/DUT instruments.
-
Product
Calibration Short For Digital Multimeters
34172B
-
The Keysight 34172B digital multimeter calibration short is a set of two shorts which provide a convenient and reliable method to apply a short to the input connectors of the multimeter. Terminals are made of low-thermal copper alloys to minimize thermally-induced voltages caused by dissimilar metals.
-
Product
High-Performance Multifunction Calibrator
5730A
-
The new 50 MHz wideband option for the 5730A High-Performance Multifunction Calibrator provides expanded wideband capabilities to self-maintaining laboratories by providing a method to calibrate the 50 MHz input of the 5790B AC Meaasurement Standard. This is accomplished by characterizing the 5730A's 50 MHz output using a precision thermal voltage converter (TVC), thus reducing uncertainties to calibrate the 5790B.
-
Product
Bulk Acoustic Wave Technology
BAW
-
Macom Technology Solutions Holdings Inc.
MACOM’s BAW product portfolio is ideal for high performance Industrial, Aerospace, Defense, and Communications applications that require critical frequency filtering. Our high-performance RF filters enable our customers manage signal integrity in the 1 to 6 GHz frequency range. Bulk Acoustic Wave Resonators consist of two metal electrodes above and below a layer of a piezoelectric material. The piezoelectric material converts an electrical signal to a mechanical signal and vice versa. The metal electrodes provide the connections to/from the piezo material. The frequency at which resonance occurs depends on the thickness of the combined metal-piezo-metal stack. Advances in thin-film piezoelectric fabrication have enabled BAW resonators to meet RF filtering challenges up to 6000 MHz using standard MEMS fabrication process. High-performance BAW resonators-based RF filters are made of piezoelectric material having high Q-factor (>3000) and high coupling coefficient. Currently, no competitive technology provides the same high performance for RF filter applications when compared to BAW resonator-based RF filter up to 6000 MHz for the same size and cost.
-
Product
Acoustic Compound Protection System
ACOMPRIS
-
Static kind of infrastructure is often vulnerable to attacks by either small arms fire (SAF) or mortars. The objects could be for instance a military forward operating base, an embassy or a post from the United Nations. As attacks may occur all the time, persistent and affordable protection is required. Especially when inhibited by civilians, ease of operations use and maintenance become more important. Often installed in remote places far away from the electricity grid, power consumption is an issue.
-
Product
Conformance Calibration Standard Test Card for ITF-14 (Interleaved 2 of 5) Symbol Verifiers
AI-CCS-ITF-14
-
This test card is ideal for testing verifiers, scanners, and other ITF-14 (Interleaved 2 of 5) barcode reading equipment. It also can serve as an excellent training aid to ensure new operators are using the proper methodology and are proven competent in the use of verifiers.
-
Product
Workstation For Acoustic & Vibration Engineering
imc WAVE 2022
-
imc WAVE is a modular, powerful software platform for noise and vibration analysis (NVH analysis). From noise investigations in road tests to structural analyses on the test bench and vibration tests on machines: with different imc WAVE analyzers, you can evaluate a wide range of applications without having to be an expert yourself. In this way, you can also easily and reliably obtain standard-compliant analysis from the fields of noise and sound power analysis, structure analysis as well as the evaluation of the analysis of vibrations and of rotating machines. imc WAVE guides you step by step through the settings, from device configuration to calibration and measurement. In the end, you evaluate your data professionally and then receive a report that is ready to print. The modular software specializes in the following topics.
-
Product
Ice Point Calibrators
-
These ice point calibrators are designed to accurately calibrate probes at the freezing point of water. These devices have multiple thermowells to calibrate multiple sensors simultaneously.
-
Product
Coaxial Calibration Kits
-
Rosenberger Hochfrequenztechnik GmbH & Co. KG
Rosenberger offers the following types of calibration kits with a range of coaxial connector series for vector network analyzers (VNAs). All Rosenberger calibration kits can be used from DC to their maximum frequency. Full version with adaptors and sliding loads for variable measurements Industrial version for standard measurements LRL and TRL version
-
Product
Mercury Argon Calibration Source
HG-1
-
The compact, low-cost HG-1 Mercury Argon Calibration Source is a spectral wavelength calibration source for UV-VIS-Shortwave NIR spectrophotometric systems.
-
Product
Bench Power Supply, Calibrated w/Data, Adjustable, 1 Output, 0 V, 30 V, 0 A, 5 A
72-2690 CAL D
-
The 72-2690 CAL D from Tenma is a single channel adjustable bench top power supply. It is a digitally controlled industrial grade power supply with load for a long time. This compact design power supply has complete digital control, intelligent temperature controlled fan, low noise and low ripple. It also features knob lock function to avoid improper operation. This power supply has load regulation ≤0.01% +2mV (voltage), ≤0.1% +5mA (current) and line regulation of ≤0.01% +3mV (voltage), ≤0.1% +3mA (current). The setting accuracy (25°C ±5°C) is ≤0.5% +20mV (voltage), ≤0.5% +10mA (current).
-
Product
Decade Box, Calibrated W/Data, Resistance, 7, 1ohm to 11.11111Mohm, 1 %
72-7270 CAL D
-
The 72-7270 CAL D from Tenma is a resistance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set resistance value from 1 to 11,111,110 ohm in one ohm increments. The decade accuracy is ±1% resistors used throughout. It has weight of 320g/0.70lb and dimension 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
4-in-1 OSLT Calibration Kit, DC to 18 GHz, Type-N (f) 50 Ohm
CK519A
-
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
Product
Antenna Calibration
-
TDK Test Services offers testing to domestic and international EMC test regulations, including IEC, ISO, CISPR, and SAE. Test services are offered in our 3m semi-anechoic chamber, 3m fully-anechoic chamber, 10-meter open area test site, and our shielded conducted test chamber.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 7mm, 2 Port
85091D
-
The Keysight 85091D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
Process Calibrators
-
We offer process calibrators that are designed for the process industry applications and to be used in the demanding conditions in process industry.
-
Product
Color Calibration & Profiling
-
For both amateurs and professionals photographers, filmmakers, designers, premedia and printing operators achieving predictable results from capture to output can be a challenge. Color Perfectionists turn to X-Rite for affordable, professional, quality calibrating and profiling solutions that make sure all of your devices monitors, projectors, cameras, scanners, printers and mobile devices are speaking the same language.
-
Product
Palm Size Digital Multimeter, Calibrated, 1999 Count, Mean Value, Manual Range, 3.5 Digit
72-7770 CAL D
-
The 72-7770 CAL D from Tenma is a palm sized digital multimeter with 3 3/4 digit LCD. It is 3 1/2digits with steady operations, fashionable design and highly reliable hand held measuring instrument. The meter measures AC/DC voltage, AC/DC current, resistance, temperature, diode and continuity. It is an ideal tool for maintenance. The multimeter features square wave output, data hold, low battery indicator and display backlight, This meter complies with the standards CE, IEC61010, in pollution degree 2, overvoltage category (CAT I 600V, CAT II 300V) and double insulation.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 3.5 Mm, 2 Port
85093D
-
The Keysight 85093D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.





























