Sound Calibration
assure sound measurement accuracy.
See Also: Sound Calibrators, Acoustic Calibration, Sound, Microphone Calibration
-
Product
Mechanical Calibration Kit, 12.4 To 18.0 GHz, Waveguide, WR-62
P11644A
-
The Keysight P11644A calibration kit contains the precision mechanical standards required to calibrate the systematic errors of Keysight network analyzers. This calibration kit has a precision airline for performing the thru-reflect-line (TRL) calibration, the most accurate error-correction technique for coaxial measurements. This kit also contains a commercial calibration certificate, flush short circuit, a precision shim, and fixed termination(s).
-
Product
Electronic Calibration Module (ECal), 67 GHz, 1.85 Mm, 2-Port
N4694D
-
The Keysight N4694D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4694D is a precision 2-port ECal module that supports 1.85 mm connectors up to 67 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4694D is included for securing your ECal module and accessories.
-
Product
15-meter (49 feet) Sensor Cable
E1739C
-
The E1739C 15-meter (49 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System. Other cable lengths available: E1739A 5-meter (16 feet), E1739B 10-meter (33 feet) and E1739D 25-meter (82 feet).
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16
85038A
-
The Keysight 85038A calibration kit contains open circuits, short circuits and terminations with both male and female 7-16 connectors and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
Product
Linear Measurement Kit
55280B
-
The Keysight 55280B Linear Measurement Kit is part of the 5530 Laser Calibration System and enables the system to measure linear displacement and velocity along a machine's travel path. The purpose of this measurement is to document capability and, when possible, improve positioning accuracy along an axis for any machine that requires positioning accuracy and velocity control.
-
Product
FD-11634, 8-Channel Sound and Vibration Input Device for FieldDAQ
786471-01
-
The FD-11634 can measure signals from integrated electronic piezoelectric (IEPE) and non-IEPE sensors such as accelerometers, tachometers, and proximity probes. The device also works with smart TEDS sensors, delivers a wide … dynamic range, and incorporates software-selectable AC/DC coupling and IEPE signal conditioning. The input channels simultaneously measure signals and have built-in anti-aliasing filters that adjust to your sample rate. This device is IP65/IP67-rated to be dust-tight and water-submersible and can sustain 100 g shock and 10 g RMS vibration in -40°C to 85°C environments. You program the FD-11634 with NI-DAQmx, which automatically synchronizes multiple FieldDAQ™ devices. When used with NI software, this device can provide processing functionality for condition monitoring such as frequency analysis and order tracking.
-
Product
Linear/Angular Measurement Kit
55281B
-
The Keysight 55281B Linear/Angular Measurement Kit is part of the Keysight 5530 Laser Calibration System and enables the system to measure both linear velocity along a machine's travel path as well as rotation about an axis perpendicular to the axis of motion (pitch and yaw).
-
Product
Cal Kit, 4-in-1 OSLT, DC To 26.5 GHz, 3.5 Mm(f)
85521A
-
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
Product
Sound Level Calibrator
511E
-
Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 9 GHz, Type-N(m), 50 Ohm
85514A
-
Easily calibrate non-insertable devices with a type-N (m) 50 Ω open, short, load, and through in a compact unit
-
Product
Diagonal Measurement Kit
10768A
-
The Keysight 10768A Diagonal Measurement Kit is designed for use with the Keysight 5530 Laser Calibration System. It allows linear measurements to be made on the four body diagonals of a machine tool's working volume. These measurements document the machine's capability and quickly perform a complete check of volumetric positioning performance. In addition, long-term drift tests can be performed over hours or days, showing possible effects of temperature on geometry.
-
Product
Multiport Electronic Calibration Module (ECal), DC To 20, 6-ports
N7564A
-
A series of multiport ECal that cascade-able up to 36-ports which makes it possible to calibrate a wide frequency range from DC up to 20 GHz without making numerous connections during calibration process. Ideal for multiport measurement application with VNA in such as high-volume PA/FEM, massive MIMO antenna or high-speed digital interconnect test applications
-
Product
Precision Mechanical Calibration Kit, DC To 26.5 GHz, 3.5 Mm
85052C
-
The Keysight 85052C precision mechanical calibration kit contains precision standard devices to characterize the systematic errors of Keysight network analyzers in the 3.5 mm interface. This kit also contains adapters to change the gender of the test port and a torque wrench for proper connection.
-
Product
Sound Level Calibrator
521
-
Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.
-
Product
Standard Mechanical Calibration Kit, DC To 3 GHz, Type-N, 75 Ohm
85036B
-
The Keysight 85036B calibration kit contains precision 75 ohm type-N standards used to calibrate Keysight network analyzers for measurement of devices with 75 ohm type-N connectors. Standards include fixed terminations, open circuits, and short circuits in both genders. This kit is specified from dc to 3 GHz.
-
Product
CalPod Drive Cable Extension, 10 Meter
85554A
-
85554A CalPod Drive Cable (10 meter length) extends the length of CalPod control cables when the distance between the 85523B to the CalPod modules is >2 m.
-
Product
Sound Level Meters & Calibrators
-
A sound level meter, also known as sound pressure level (SPL), decibel (DB) meter, noise meter or noise dosimeter is mainly used for measuring sounds travelling through air. It is used to test noise or sound levels by evaluating sound pressure. It uses a microphone to capture sound and the sound is then evaluated in the device. It is commonly used to prevent loud noises to create a better work environment.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 7mm, 2 Port
85091D
-
The Keysight 85091D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
PXIe-4463, 51.2 kS/s, 2-Output PXI Sound and Vibration Module
783086-01
-
The PXIe‑4463 offers high dynamic range and THD+N for audio, acoustic, and vibration applications. It provides the high precision and dynamic range necessary for the most stringent audio generation requirements in a modular form … factor. The PXIe‑4463 contains two 24-bit digital‑to‑analog converters to allow for fully differential simultaneous generation. Complete with three gain ranges, the PXIe‑4463 can generate current with programmable, per channel output configurations. The two timing engines allow you to perform multisample-rate applications on a single module and independently start and stop channels on a single module.
-
Product
NI-9230, 3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
783824-02
-
3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9230 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9230 is also compatible with smart TEDS sensors. The NI‑9230 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
Product
Sound Meter
4431
-
The Kanomax Sound Meter – Model 4431-1G is the world’s first 0-dB function sound meter available. It is designed to meet Type 2 standards for ANSI S1.4 1983 and IEC 61672-1. The magnetic accelerometer easily attaches to machinery for increased accuracy and precise operation.
-
Product
USB-4431, 102.4 kS/s, 100 dB, 0.8 Hz AC/DC Coupled, 4-Input/1-Output Sound and Vibration Device
780164-01
-
The USB-4431 is designed for sound and vibration measurements. Input channels incorporate integrated electronic piezoelectric (IEPE) signal conditioning for accelerometers and microphones. The four USB-4431 input channels simultaneously digitize input signals. The analog output (AO) channel is ideal for stimulus-response tests and can be synchronized to the AI channels.
-
Product
PXI Sound and Vibration Module
-
PXI Sound and Vibration Modules are designed specifically for applications like audio test and measurement, noise and vibration diagnostics, machine condition monitoring, automotive test, noise, vibration, and harshness(NVH) analysis, and laboratory research. They provide software-configurable AC/DC coupling, antialiasing filters, and IEPE conditioning to ensure precision measurements with microphones, accelerometers, and other transducers with large dynamic ranges.
-
Product
Mechanical Calibration Kit, 18 To 26.5 GHz, Waveguide, WR-42
K11644A
-
The Keysight K11644A calibration kit contains the precision mechanical standards required to calibrate the systematic errors of Keysight network analyzers. This calibration kit has a precision airline for performing the Thru-Reflect-Line (TRL) calibration, the most accurate error-correction technique for coaxial measurements. This kit also contains a commercial calibration certificate, flush short circuit, a precision shim, and fixed termination(s).
-
Product
Calibrator
-
Shijiazhuang Suin Instruments Co., Ltd.
Is a device used to adjust an instrument accuracy,
-
Product
Calibrators
-
Our high accuracy calibrators work with all competitor products and offers the customer a way to maintain their equipment, while keeping the specifications of their process.
-
Product
Calibration
-
Calibration of a measuring tool is an operation that allows an assessment of the accuracy of the measurement, and the adjustment of the measuring tool so that it is more accurate. In scientific formulation, calibration makes it possible to evaluate the measurement error.
-
Product
Calibration
-
Calibrations of electronic equipment is one of the activities that Kiwa Dare offers to its clients. these calibrations are under accreditation in the field of electrical quantities. Besides calibrations in the field of DC current, DC voltage and low frequency (test and measuring) equipment, Kiwa Dare is specialized in calibrating high frequency measuring equipment and in particular EMC equipment in a frequency range of (DC) 40 GHz. New the site validation calibrations whereby Kiwa Dare can calibrate shielded rooms (Faraday room) and anechoic chambers under accreditation.
-
Product
Calibrators
-
Handheld calibrator is an exceptional instrument performing precision measurement of pressure, temperature, current or voltage. The base unit includes application-specific firmware for convenient instrument calibration and logging of associated data. In addition, the ATE-2 has the ability to interface the system with a computer, data acquisition system or dumb terminal via the standard USB interface.





























