Line Replaceable Unit
unit of a complex engineered system, designed for quick replacement.
See Also: LRU
-
Product
GPU
-
The MAGIC1A is a rugged line replaceable unit (LRU) suitable for high-performance computing in the harshest of environments. The combination of Intel and NVIDIA processors in a low SWaP-C3 package ensure it can be used across a wide range of commercial and military applications, including displays, situational awareness, data/radar processing, video processing, classification, and artificial intelligence (AI).
-
Product
MAX629 Bus Connect
-
The MAX629 Bus Connect panel is a 19 inch rack mount or table top device to connect together ARINC 629 Line Replacement Units (LRUs) without the need for ARINC 629 couplers. This is the ideal solution for tests & simulation benches.
-
Product
Processor and NVIDIA Quadro GPU
MAGIC1A
-
The MAGIC1A is a rugged line replaceable unit (LRU) suitable for high-performance computing in the harshest of environments. The combination of Intel and NVIDIA processors in a low SWaP-C3 package ensure it can be used across a wide range of commercial and military applications, including displays, situational awareness, data/radar processing, video processing, classification, and artificial intelligence (AI).
-
Product
Avionics Suite Tester
-
Based on order from the Navy, Data Patterns developed the complete Automated Test Equipment required for validating all the Line Replaceable Units (LRUs) utilized in the Seaking Helicopter. The upgrade was carried out at multiple Naval bases in India.
-
Product
Intermittent Fault Detection & Isolation System
IFDIS
-
The IFDIS™ uses patented Intermittent Fault Detector technology that simultaneously and continuously monitors every circuit path within a Unit Under Test (UUT) - such as a Line Replaceable Unit (LRU) chassis' interconnects - for intermittent continuity failures that occur for as short as 50 nanoseconds. This state of the art technology is combined with an environmental chamber and vibration table, which simulate the UUT’s operational environment and cause intermittent faults to manifest, creating a system that is unsurpassed in intermittent fault detection.
-
Product
500 Watt AC/DC Power Line Conditioner, 3U VPX, Holdup Time
VPX56-3HU
Power Line Conditioner
NAI's VPX56-3HU is a rugged, high-performance 500-Watt Output +28 VDC Input 3U VPX AC/DC Power Line Conditioner designed for aerospace, defense, and industrial markets. This off-the-shelf power supply plugs directly into a standard VPX conduction cooled chassis and protects downstream DC-DC converters from MIL-STD-704 transients, low-voltage conditions and power interruptions, providing up to 50 milliseconds of holdup time at up to 500-Watts. Continuous Background Built-In-Test (BIT) and I2C communication are included.
-
Product
72.5-Watt DC Power Line Conditioner w/Holdup
44KS3-02
Power Line Conditioner
NAI's 44KS3-02 is a 72.5-Watt Power Line Conditioner with holdup time that protects downstream DC/DC converters from transients, low voltage conditions, and power interruptions. This unit accepts +28 VDC input and provides a single output at 72.5 Watts either 22.5 to 30 VDC with holdup time or +16 VDC without holdup time - to all downstream DC/DC converters.
-
Product
100-Watt DC Power Line Conditioner w/Holdup
44LS1
Power Line Conditioner
NAI’s 44LS1 is a 100-Watt Power Line Conditioner with holdup time that protects downstream DC/DC converters from transients, low voltage conditions, and power interruptions. This unit accepts +28 VDC input and provides 22.5 to 30 VDC at 100 Watts to all downstream DC/DC converters.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
42-203-002
Fault Insertion Unit
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
VPX55-3HU 3U VPX Power Line Conditioner with Holdu
VPX55-3HU
Power Line Conditioner
The VPX55-3HU is a 400-Watt DC/DC Power Line Conditioner which plugs directly into a standard 3U VPX chassis with a VITA 62 0.8" or 1.0" power slot. This off-the-shelf solution is compatible with VPX specifications and addresses the need for 3U VPX power applications requiring an optional VITA 62 Energy Storage Module.
-
Product
DFB Laser Source Module
LaserPXIe 1200 Series
Source Measure Unit
The LaserPXIe 1200 Series is a highly customizable DFB laser source available in a wide range of wavelengths and powers.
-
Product
6x 3U OpenVPX MOSA Remote Interface Unit
SIU36-RIUVARM-01
Remote Interface Unit
SIU36-RIUVARM-01 is a Modular Open Systems Approach (MOSA) Remote Interface Unit (RIU) to manage, monitor and control connected I/O, communications, measurement and simulation interfaces through Ethernet commands from a main mission processors. Extremely low power with 2 x 10/100/1000Base-T Ethernet.
-
Product
PXIe-4141, 4-Channel, ±10 V, 100 mA, Precision PXI Source Measure Unit
781743-01
Source Measure Unit
PXIe, 4-Channel, ±10 V, 100 mA, Precision PXI Source Measure Unit - The PXIe-4141 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4 wire) sensing for accurate measurements. The fast sample rate of the PXIe-4141 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4141 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
-
Product
64-Ch 1-Bus Fault Insertion
YAV91082
Fault Insertion Unit
64 channels 1 thread 2A 250V 1 Fault Insertion Buses Switching up 60W CAN Control (or Ethernet with Ethernet to CAN Gateway) Drivers dll & VIs available
-
Product
Dual Function Slot MOSA Data Concentrator Unit (DCU)
NIU2A-DCU-01
Data Concentrator Unit
NIU2A-DCU-01 is a Modular Open Systems Approach (MOSA) Data Concentrator Unit with low power high performance ARM Cortex -A9 processing. 512 MB RAM, 32 GB SATA Flash, 2 x 10/100/1000Base-T Ethernet and optional Fiber Optic Ethernet support
-
Product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 8 Channel
40-201-008
Fault Insertion Unit
This high bandwidth differential PXI fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
Product
PXI/PXIe Fault Insertion Switch, 74-Chan 2A, N/C Through Relays, Fault Buses on M & U
40-190C-012
Fault Insertion Unit
The 40-190C-012 (PXI) and 42-190C-012 (PXIe) are fault insertion switches with 74 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI/PXIe Source Measure Unit Family
PXS(e)840x
Source Measure Unit
The PXS840x PXI SMU family is a high-speed, 4-quadrant source measure unit. Carry out measurements directly on the DUT with the integrated CMU and VMU.
-
Product
50 µs Pulse Medium Current Source/Measure Unit (MCSMU)
B1514A
Source Measure Unit
The 50 s Pulse Medium Current SMU is an SMU designed for faster pulsed IV measurement. It enables a pulsed measurement down to 50 s pulse width, a 10 times or more narrow pulsed measurement than provided by a comparable conventional SMU. In addition, the instrument offers a wider range and versatility, up to 30 V / 1A, with voltage/current programmability. It is useful to characterize high to medium power devices on the new materials such as SiC and GaN, and organic devices, and the MCSMU expands your choices of pulsed IV measurement.
-
Product
PXI 34-Channel 4-Bus 2A Fault Insertion Switch
40-197A-001
Fault Insertion Unit
This 34-channel fault insertion switch is primarily intended for routing simulated fault conditions in automotive and aerospace applications involving the reliability testing of safety critical controllers. A low cost 16-channel option is also available.
-
Product
Single Bus 64-Channel 2A PCI Fault Insertion Switch
50-190-101
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
42-203-001
Fault Insertion Unit
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
Ethernet/AFDX/BroadR-Reach PCI Fault Insertion Switch - 8 Channel
50-201-008
Fault Insertion Unit
This high bandwidth differential PCI fault insertion card is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This card supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground.
-
Product
PXI Isolated Single Channel Voltage/Current Source, 100V
M9186A
Source Measure Unit
The V/I source lets you source a voltage and measure the resultant current, or source a current and measure the resultant voltage. It consist of two separate amplifiers, denoted "low" and "high" that share a common output connection. The "low" amplifier provides voltages in the range of 16 volts at up to 200ma and the "high" amplifier provides voltages in the range of 100V at up to 20mA.
-
Product
Single Bus 75-Channel 2A PCI Fault Insertion Switch
50-190-001
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 6-Channel
40-203-002
Fault Insertion Unit
The 40-203-002 (PXI) and 42-203-002 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 6 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
High-Density Precision SMU (100 PA, 30 V)
PZ2130A
Source Measure Unit
The Keysight PZ2130A is a high-channel density precision source / measure unit (SMU) with 5 channels per module that saves space at a low cost per channel for a wide range of applications requiring numerous precision power supplies. Its seamless current measurement ranging function eliminates the time it takes to change the range and expands the dynamic range to cover multiple measurement ranges, which reduces test duration. These capabilities make the PZ2130A suitable for applications that require numerous precision power supplies, such as semiconductor reliability tests and integrated circuit (IC) tests. The Keysight PX0107A low noise filter adapter lowers its voltage source noise level, which makes the PZ2130A suitable for noise sensitive applications such as quantum computing as well.
-
Product
Source Measurement Unit
PEMU4
Source Measure Unit
The PEMU4 represents a new level of performance and capabilities for USB-based SMU (Source MeasurementUnit) instrumentation. The PEMU4 supports -1V to +6.5V 0.5A with FVMI, FVMV, FIMV, FIMI modes. 4 channel can be ganged to support high current driving. I2C/SPI/RFFE function for serial port device testing. 4 Counter for frequency measurement.
-
Product
PXI Dual Bus 32-Chan 2A Fault Insert Switch
40-190B-202
Fault Insertion Unit
The Dual Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXIe-4142, 4-Channel, ±24 V, 150 mA PXI Source Measure Unit
782430-01
Source Measure Unit
PXIe, 4-Channel, ±24 V, 150 mA PXI Source Measure Unit - The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. The fast sample rate of the PXIe-4142 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules.