Data Acquisition Systems
sense, log and store information. Also known as: DAS
See Also: Data Acquisition, PCI Data Acquisition, DAQ
-
Product
Instrumentation Amplifier
AAF-3G
-
Programmable, 2-Channel Instrumentation Amplifier for the AAF-3, AAF-3PCI, PGA-16 and OEM Data Acquisition Systems.
-
Product
PXI 2A Multiplexer, 2-Bank, 16-Channel 4-Pole
40-614-012
Multiplexer Module
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
Product
PXI MUX 1-Bank of 80 Channel 1-Pole
40-615-021-1/80/1
Multiplexer Module
High density multiplexer modules featuring a wide range of switching configurations, especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems. Each module is factory configured into one of the configuration modes. Connections are made via a front panel 200-pin connector.
-
Product
PXI/PXIe Very High Density Multiplexer, 5-Channel, 32-Pole
42-675B-002-5/32
Multiplexer Module
The 40-675B-002-5/32 (PXI) and the 42-675B-002-5/32 (PXIe) are 5-channel, 32-pole multiplexers and are part of our range of very high density low cost multiplexer modules. These modules are suitable for signal routing in high channel count ATE and data acquisition systems.
-
Product
PXIe Very High Density Multiplexer, 2A, 79-Channel, 2-Pole, Multiple Channel Mode
42-611B-002-M
Multiplexer Module
The 40-611B-002 (PXI) and 42-611B-002 (PXIe) modules are 79-Channel 2-Pole multiplexers. A 158-Channel 1-Pole configuration is also available. They use high quality electro-mechanical signal relays allowing switching up to 2 A and voltage up to 300 VDC/240 VAC. They are suitable for signal routing in high channel count ATE and data acquisition systems. Connections are made via a front panel 160-pin DIN 41612 connector.
-
Product
Single 32x4 1-Pole High-Density PXI Matrix Module
40-520-401
Matrix Switch Module
The 40-520 family of high-density PXI matrices is available in 22 different configurations with up to 256 crosspoints. The choice of six bus widths (x16, x12, x8, x6, x4 and x2) enables competitively priced solutions using Pickering Electronics instrumentation quality reed relays. These relays offer very long life with good low-level switching performance and excellent contact resistance stability. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
PXI 2 Amp Multiplexer, Dual 4-Channel, 4-Pole
40-635A-107
Multiplexer Module
The 40-635A-107 is a dual 4-channel, 4-pole MUX and is part of a range of Multiplexer modules available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC. The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
Temperature Data Acquisition
THERMES-USB
-
Physitemp’s Thermes high accuracy data acquisition system has been redesigned to create a more versatile USB model. The new system requires no internal connections to your computer and simply connects via an external USB port on your laptop or desktop computer. Two versions of the data acquisition system are available. The standard version, THERMES USB, is connected to your computer USB port. The wireless version - THERMES USB WFI, can be either directly connected to a USB port or, with the included wireless receiver, positioned up to 100 feet from the host computer. Each unit will accommodate up to 7 type T thermocouple sensors and multiple Thermes units may be connected to the same computer for more thermocouple inputs. A high accuracy electronic cold junction compensation circuit maintains typical system accuracy of ±0.2°C over an ambient temperature range of 15 to 35°C. Individual offsets may be added to each input in software to facilitate individual calibration of each channel. (see THERMES-USB WFI)
-
Product
6U High-Density PXI Matrices
-
High-density matrices suitable for signal switching in ATE and data acquisition systems.
-
Product
Test Automation System for Brake Testing
STARS Brake
-
STARS Brake is an integrated automation, data acquisition and control system platform that provides a comprehensive application functionality in a single, powerful environment. STARS Brake is designed to address the needs of a wide range of brake testing applications from component development to final component and system validation. It offers users a level of flexibility and openness that enables thorough investigations of brake systems.
-
Product
PXI High Density Multiplexer, 8-Bank, 8-Channel, 1-Pole
40-610A-009
Multiplexer Module
The 40-610A-009 is a 8-bank, 8-channel, 1-pole MUX and is part of our range of PXI high density reed-relay based multiplexer modules. The range includes a wide choice of switching configurations which are especially useful where a large number of small multiplexers are required. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
PXI 2 Amp Multiplexer, Dual 32-Channel, 1-Pole
40-635A-005
Multiplexer Module
The 40-635A-005 is a dual 32-channel, 1-pole MUX and is part of a range of Multiplexer modules available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC. The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.
-
Product
Single 24x6 1-Pole High-Density PXI Matrix Module
40-520-302
Matrix Switch Module
The 40-520 family of high-density PXI matrices is available in 22 different configurations with up to 256 crosspoints. The choice of six bus widths (x16, x12, x8, x6, x4 and x2) enables competitively priced solutions using Pickering Electronics instrumentation quality reed relays. These relays offer very long life with good low-level switching performance and excellent contact resistance stability. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
Computer Automated Data Acquisition
System 471
-
The NEFF System 471 (S471) DAS is a complete moderate-speed DAS for use in computer-based applications. The S471 is designed primarily for computer automated data acquisition in test facilities, laboratories and industrial plants or wherever a moderate-speed, high accuracy DAS operating in high common-mode voltage environments is required.
-
Product
Temperature Sensors
TT420
-
Features • 2-wire, loop-powered 4-20mA analog output • Attachment probe, sensor, and 2-wire 4-20 mA signal conditioner • Compatible with PLCs, meters, and data acquisition systems • No user calibration • TT420Z 1/4" stainless steel probe • TT420S 1/4-28 threaded stud – screws into any 1/4-28 tap • TT420F mounts onto any flat surface • UL listed, Intrinsically Safe (IS) • Class I, (C, D) and Class II, (E, F, G)
-
Product
PXI 2A Multiplexer, 1-Bank, 64-Channel 2-Pole
40-614-016
Multiplexer Module
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
Product
PXI 2A Multiplexer, 4-Bank, 16-Channel 2-Pole
40-614-007
Multiplexer Module
The 40-614 High Density 2 Amp multiplexer module is available in 20 configurations. All configurations use high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 200VDC/140VACThe module is suitable for signal routing in ATE and data acquisition systems. User connections are made via a front panel 160-pin DIN 41612 connector which is fully supported by our range of cabling and connector solutions.
-
Product
PXI Ultra High Density 64x4 2-Pole Matrix
40-533B-022
Matrix Switch Module
The 40-533B ultra high density matrix module is configured as 64x4 or 64x2 and is available in a choice of 1-pole and 2-pole reed relay formats. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109operations to give maximum switching confidence with long life and stable contact resistance. Larger matrices may be constructed by daisy chaining the common signals from multiple PXI modules.
-
Product
DynoLAB Test Cell Supervisory System
-
SAKOR Technologies’ DynoLAB™ data acquisition and control systems offer reliable, cost effective automation of all types of dynamometer test systems. As with all SAKOR products, the DynoLAB system undergoes a continuous program of upgrade and improvement, regularly expanding and enhancing DynoLAB’s capabilities.
-
Product
PXI Single 32x8 Matrix, 2 Pole Switching
40-531-022
Matrix Switch Module
Model 40-531 very high density matrix modules are configured as a 32x8, while the 40-532 modules are configured as a Dual 16x8. Both modules are available in a choice of reed relay formats: 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching coaxial signals up to 50MHz. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability Sputtered Ruthenium Reed Relays, offering 109 operations to give maximum switching confidence with long life and stable contact resistance. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules. For example, seven PXI modules will form a 224x8 Matrix, a total of 1792 crosspoints in a 7-slot PXI Chassis.
-
Product
Data Acquisition System
Pixie-16
Data Acquisition Module
The Pixie-16 is a data acquisition system for nuclear physics and other applications requiring coincident radiation detection with large number of channels.
-
Product
16 Channel USB Sensor Interface
RogaDAQ16
-
With the introduction of the RogaDAQ16 USB 2.0 data acquisition system, a new age of measurement technology begins.*USB 2.0 / 480MBIT (USB1.1/12MBIT COMPATIBLE)*16 analog input channels (16bit/500kHz max.)*ICP ® ( IEPE ) sensor supply (24V/4mA)*0.125V to 10V input range*Individual preamplifiers*4 analog output channels (16bit/100kHz)*Powerful DSP (255MIPS) for filtering, control etc.*24 digital I/Os*Optional 24bit counter, timer, PWM, incremental encoder*Free drivers for major application software*including DASYLab; LabView & DiaDem drivers & RogaRec Software
-
Product
MINITAURs - 8-channel universal DAQ system
MINITAUR-S
-
Mixed signal 8-channel data acquisition system and multichannel data logger with cutting-edge technology at an attractive price. Universal analog inputs can accommodate various signals like strain gage, IEPE, voltage, current, RTD, thermocouple, and LVDT.
-
Product
PXI High Density Matrix Module, 16x16, 2-Pole, 2A
40-582A-001
Matrix Switch Module
The 40-582A is a 256 crosspoint PXI matrix with dual pole switching. The module consists of a 16x16 matrix of 2-pole electro-mechanical relays with 2A current handling. The module is designed for switching medium voltage and power signals, typical applications include signal routing in ATE and data acquisition systems.
-
Product
Battery Portable Passive Intermodulation Analyzer
iPA Series
-
The iPA Series Passive Intermodulation (PIM) analyzer is the first battery powered PIM Test Analyzer versatile enough to support multiple test scenarios such as testing at the top of the tower, base of tower, roof top and in-building for DAS systems. This IEC compliant 20W, rugged, battery operated design includes a tablet computer in a ruggedized case for remote control. This allows hands-free dynamic testing that is safe and convenient. Add the optional Range to Fault (RTF) module to quickly identify the location of PIM and Return Loss sources.
-
Product
Communication Devices
-
Communication devices store and retrieve data acquired by data acquisition systems. These devices facilitate the accessibility, analysis, sharing, and reporting of data. Our available communication devices include both on-site and telemetry peripherals, which can be used in the same application for maximum flexibility, convenience, and reliability.
-
Product
Multimeter/Data Acquisition/Switch Systems
Keithley 2700
-
Each Series 2700 system combines precision measurement, switching, and control in a tightly integrated enclosure for either rack-mount or bench-top applications. Although the core functionality and programming of all three systems are identical, each mainframe has unique capabilities. For example, the Model 2701 provides a 10/100BaseTX Ethernet interface, and the Model 2750 offers extended low ohms measurement capability. All models are compatible with the same line of plug-in multiplexer, matrix, or control modules. See all digital multimeters »
-
Product
PXI High Density Multiplexer, 47-Channel, 2-Pole
40-640A-022-47/2
Multiplexer Module
The 40-640A-022-47/2 is a 47-channel, 2-pole MUX and is part of a series of high density multiplexer modules featuring a choice of switching configurations. Typical applications include signal routing in ATE and data acquisition systems.
-
Product
PXIe Digitizer: 100 MSa/s, 14 bit, 100 MHz
M3100A
Digitizer
The M3100A PXIe digitizer is ideal for general purpose digitizer automated test requirements. It offers high channel density with an advanced data acquisition systems (DAQ). The optional real-time sequencing, inter-module synchronization, and graphical FPGA programming software tools expand its capability to enable a number of solutions including angle of arrival (AoA), baseband electronics designs, wireless device manufacturing and multi-channel coherent signal acquisition.
-
Product
PXI High Density Mux 10 Channel 8 Pole
40-670A-021-10/8
Multiplexer Module
The 40-670A series of very high density multiplexer modules feature a wide range of switching configurations. Typical applications include signal routing in ATE and data acquisition systems. The 40-670 multiplexer may be operated as a conventional multiplexer with break-before-make action when a new channel is selected. In addition multiple channels may be simultaneously selected (not available in 1 pole mode).