Probe Interfaces
Connect ATE instrumentation to interface test adapter.
-
Product
Super 3.90 (111.00) - 16.00 (454.00) High Performance Lead Free Probe
LFRE-25I40-16
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) General Purpose Probe
HPA-40A
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 35Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 660Overall Length (mm): 16.76
-
Product
NI-9881, 1-Port C Series CANopen Interface Module
781673-02
Interface Module
The NI‑9881 is a high-speed CANopen interface for developing CANopen applications in LabVIEW software on CompactRIO hardware. CANopen is the application layer that sits on top of the CAN physical layer often used for industrial automation … applications. It was designed for motion-oriented machine control networks, such as handling systems, but now it is used in a variety of applications, including medical equipment, off-road vehicles, maritime electronics, public transportation, and building automation. The NI‑9881 can transmit/receive process data objects (PDOs) and service data objects (SDOs) according to CiA‑DS 301. The NI‑9881 is compatible with only CompactRIO systems.
-
Product
Alternate 2.39 (68.00) - 6.00 (170.00) High Performance Bias Ball Probe
POGO-1T24-6
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Ultra High 2.84 (81.00) - 10.00 (283.00) High Performance Bias Ball Probe
POGO-1H-10-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Alternate 1.30 (37.00) - 4.50 (128.00) General Purpose Probe
HPA-1J-1
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Alternate 2.50 (71.00) - 5.80 (164.00) General Purpose Probe
P2665G-1R2S
General Purpose Probe
Current Rating (Amps): 15Average DC Resistance lower than (mOhm): 10Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 230Full Travel (mm): 5.84Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,290Overall Length (mm): 32.77Overall Length Remark: Tip 2W: 1270 mil (32.26 mm)
-
Product
AC/DC Current Probe (2-Channel), 3 MHz, 50 UA
N2820A
Oscilloscope Probe
The N2820A 2-channel current probe connects to two oscilloscope channels to provide simultaneous low- and high-gain views for wider dynamic range measurement, while the N2821A 1-channel current probe provides one user-selectable view at a time.
-
Product
Light 0.60 (17.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-72T38-2
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
COM Express Type 7 10GBASE-T Network Adapter Card
CEI-4x10GBASE-T
Network Interface Controller
- Support up to four 10GbE copper interfaces (10GBASE-T)- COM.0 R3.1 Type 7 compliant- Dedicated for Express-ID7
-
Product
Elevated 1.68 (48.00) - 7.00 (198.00) High Performance Lead Free Probe
LFRE-1I15-7
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
SA1500X, 1.5 GHz, ±8 V, 10X Attenuation, Single-Ended Active Oscilloscope Probe
784256-01
Oscilloscope Probe
The SA1500X is single-ended, active voltage probe that is used for many different high-speed measurement applications. The probe is powered by an included auxiliary power supply that is internationally compatible and certified. You can use it with oscilloscopes that provide 50 Ω input impedance.
-
Product
Premium 4.49 (127.00) - 12.00 (340.00) High Performance Lead Free Probe
LFRE-25T79-12
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
High 1.73 (49.00) - 8.00 (227.00) High Performance Bias Ball Probe
POGO-1Z1-8
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Light 0.75 (21.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-25T79-2
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Alternate 2.58 (73.00) - 6.00 (170.00) High Performance Lead Free Probe
LFRE-25I35-6
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Light 0.75 (21.00) - 2.00 (57.00) High Performance Lead Free Probe
LFRE-25V-2
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
PMC Interface Card
CPCIC-MA4
Interface Module
The CPCIC3/6-MA4’s BC capability includes variable message/label framing/subframing with transmission scheduling provides the most advanced control operations. ARINC TX has complete frequency control per channel. RT and ARINC RX, Monitor, Playback and Signal Generator functions also include industry leading functions to meet the most demanding requirements.
-
Product
Elevated 2.65 (75.00) - 6.50 (184.00) High Performance Lead Free Probe
LFRE-25Z-6.5
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
High Force Type Probe For PCB, K100 Series 100mil Pitch, Type A, Ø0.80mm, 155gf
K100-A080155-SKAU
Spring Probe
K100 Series, Pitch 100mil, Tip Style A, Tip Diameter Ø0.80mm, Spring force 155gf, Steel with Gold Plating.
-
Product
Standard 0.70 (20.00) - 1.30 (37.00) Non Replaceable General Purpose Probe
A-S-R
General Purpose Probe
Current Rating (Amps): 2Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 30Full Travel (mm): 0.76Recommended Travel (mil): 20Recommended Travel (mm): 0.51Overall Length (mil): 230Overall Length (mm): 5.84Rec. Mounting Hole Size (mil): 38Rec. Mounting Hole Size (mm): 0.97Recommended Drill Size: #62 or 0.97 mm
-
Product
CAN/FlexRay/Differential Bus PXI Fault Insertion Switch - 8 Channel
40-200-008
CAN Interface
This PXI Fault Insertion module is designed to simulate common faults on two wire communication interfaces such as CAN Bus. This module supports 4 or 8-channels of two wire serial interfaces. Each channel can simulate an open fault in either or both wires, a short between both wires or a short to one of eight externally applied fault connections, such as a battery connection or ground, via four fault buses. Each channel can support up to 0.3A and is rated to handle up to 100V between the wire pairs. The wire pairs have controlled transmission line impedance suited to most differential pair signalling systems, including fast CAN Bus interfaces and RS232. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
Product
Alternate 2.58 (73.00) - 6.00 (170.00) High Performance Lead Free Probe
LFRE-25T36-6
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Alternate 2.39 (68.00) - 6.00 (170.00) High Performance Lead Free Probe
LFRE-1V-6
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Alternate 6.00 (17.00) - 2.50 (71.00) General Purpose Probe
P2662AG-1Q2S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1I8-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Interface Board, Low Cost, 8:1 Ethernet RJ45
40-965-901
Interface
Low cost converter card for 40-736 Data Communications Multiplexer. Adapts the 78-Pin D-type connector on the front of the module to 9 RJ45 sockets. Allows the multiplexing of up to 8 Ethernet signals with speeds up to 1G bit.
-
Product
HPA-0B General Purpose Probes
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 635Overall Length (mm): 16.13
-
Product
Light 0.83 (24.00) - 2.00 (57.00) High Performance Bias Ball Probe
POGO-1T30-2
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Premium 4.49 (127.00) - 12.00 (340.00) High Performance Lead Free Probe
LFRE-25A-12
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02