Calibration Software
Generate a reading during a calibration, analyze it, and manage the calibration data.
See Also: Calibration, Calibrators, Power Calibration, Display Calibration, Calibration Standards, Calibration Services, Calibration References
-
Product
10-meter (33 feet) Sensor Cable
E1739B
-
The E1739B 10-meter (33 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.Other cable lengths available: E1739A 5-meter (16 feet), E1739C (49 feet) 15-meter and E1739D 25-meter (82 feet).
-
Product
I-Pi SMARC Development Kit Based On Intel® 6th Gen Atom® X6425E Quad-Core SoC
I-Pi SMARC Elkhart Lake
-
The I-Pi SMARC Elkhart Lake is a SMARC-based edge solution development kit powered by Intel Atom x6425E quad-core SoC with integrated Intel UHD graphics and comprehensive high speed interfaces. Development-focused, this kit also supports the latest version of the Intel® Distribution of OpenVINO™ toolkit, which features more deep-learning models, higher inferencing performance, and fewer code changes, making developing ever simpler.
-
Product
Sensor Cable, 5 M
E1739A
-
The E1739A 5-meter (16 feet) Sensor Cable is used to connect the E1736A USB Sensor Hub to either the E1737A Material Temperature Sensor or the E1738A Air Sensor. The connectors at either end of a sensor cable are identical. It is part of the 5530 Laser Calibration System.
-
Product
COM-HPC Server Type Development Kit based on Ampere® Altra® SoC
Ampere Altra Dev Kit
-
Ampere Altra Dev Kit consists of a COM-HPC Server Base carrier paired with a COM-HPC Server Type Size E module and heatsink with fan. The module features Ampere® Altra® SoC (Arm Neoverse N1-based architecture) harnessing 32/64/96/128 Arm v8.2 64-bit cores for up to 1.7/2.2/2.8/2.6 GHz and providing support for up to 768GB DDR4 memory, offering unprecedented performance and power per watt with exceptional scalability.
-
Product
COM Express Type 10 Starter Kit Plus
COM Express Type 10 Starter Kit Plus
-
The COM Express Type 10 nanoX Starter Kit Plus consists of a COM Express Type 10 core module reference carrier board that provides two PCIe Mini Card slots, 2 RJ-45 LAN ports, 2x USB 3.0, 2x USB 2.0, 1x USB client, 2x DB-9 COM, 1x SD card socket, and Mic/Linein/ Line-out. ADLINK also provides additional development tools including a verified 10.1" LVDS panel (optional), power supply, thermal solution and cabling accessories.
-
Product
I-Pi SMARC Development Kit based on NXP® i.MX 8M Plus Quad Arm® Cortex-A53 Processor
I-Pi SMARC IMX8M Plus
-
The I-Pi SMARC IMX8M Plus is a SMARC-based smart solution development kit powered by NXP i.MX8M Plus (Quad-core Arm Cortex-A53) processor with a Neural Processing Unit (NPU) at up to 2.3 TOPS.This is the first SMARC R2.1 development kit focused on machine learning, vision, advanced multimedia, and industrial IoT with high reliability. As such, it supports dual image processors and two camera inputs for an effective Vision System, as well as applications beyond, including smart homes, building cities, and industry 4.0.
-
Product
7-Meter Laser Head Cable
10882B
-
The 10882B 7-meter Laser Head Cable is used to connect the 5519A/B Laser Head to the E1735A USB Axis Module for the 5530 Laser Calibration System.
-
Product
Economy Mechanical Calibration Kit, DC To 6 GHz, 7 Mm
85031B
-
The Keysight 85031B calibration kit contains a set of precision 7 mm fixed terminations and a one-piece open/short circuit used to calibrate Keysight network analyzers for measurement of devices with precision 7 mm connectors. This kit is specified from dc to 6 GHz.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 4.3-10, 2 Port
85094D
-
The Keysight 85094D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 40 GHz, 2.92 Mm (f)
85561A
-
Combines an open, short, load, and through standard in a compact unit that is easy to handle and lightweight.
-
Product
Electronic Calibration Module (ECal), 18 GHz, Type-N, 50 Ohm, 2-port
N4690D
-
The Keysight N4690D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4690D is a precision 2-port ECal module that supports 50-ohm type-N connectors up to 18 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4690D is included for securing your ECal module and accessories.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 9 GHz
85515A
-
The 85515A 4-in-1 mechanical calibration module combines an open, short, load, and through in a compact unit. The product is small, easy to handle, and light weight. The through allows users to easily calibrate non-insertable devices, such as a cable or filter with female-female connectors. During the “thru” part of the calibration, the 85515A through can be used.
-
Product
COM-HPC Server Type Size E Reference Development Platform based on Ampere® Altra® SoC
Ampere Altra Developer Platform
-
Backed by a broad Arm® ecosystem with an Ampere® Altra® SoC at its core, using the Arm® Neoverse™ N1 platform, the Ampere Altra Developer Platform provides premium performance from a cloud-to-edge infrastructure, keeps an extremely low thermal envelope, lower TCO, and significantly lower power consumption than x86 designs. It supports the open source EDKII as bootloader with UEFI, so customers can just download a stock AArch64 (arm64) ISO such as Ubuntu and install it through booting a live ISO directly on the target. The same convenience we have become used to by using x86 / amd64 target systems.
-
Product
Standard Mechanical Calibration Kit, DC To 9 GHz, 3.5 Mm
85033E
-
85033E Standard Mechanical Calibration Kit, DC to 9 GHz
-
Product
Rugged COM-HPC Server Type Size E Reference Development Platform Based On Ampere® Altra® SoC
Ampere Altra Developer Rugged
-
The rugged 4U rackmount server platform provides a cloud-native environment for embedded edge development. It can host the SOAFEE (Scalable Open Architecture for Embedded Edge) providing a cloud-native environment for embedded edge development and is compatible with Autoware Foundation's Autoware Open AD Kit. It supports the open source EDKII as bootloader with UEFI, so customers can just download a stock AArch64 (arm64) ISO such as Ubuntu and install it through booting a live ISO directly on the target. The same convenience we have become used to by using x86 / amd64 target systems.
-
Product
COM-HPC Server Type Ice Lake-D Starter Kit
-
The COM-HPC Server Type Starter Kit consists of a COM-HPC Server Type module, memory, and thermal solution of your choice with an extended ATX size COM-HPC Server Type reference carrier board, as well as necessary cabling. It allows you to quickly emulate the functionality of your end product for software development and hardware verification. Carrier board design files (schematics, mechanical drawings), COM-HPC module drivers, BSP, and user manual are also offered to aid you in designing your own custom carrier board.
-
Product
NVIDIA® Jetson Orin™ Nano Developer Kit
MIC-711D-ON
-
Open-frame carrier design with thermal solution. Embedded with NVIDIA® Jetson Orin™ Nano up to 67 TOPS. Supports 1 x GbE, 2 x USB 3.2 Gen 1 (5 Gbit/s). Supports 1 x mPCIe, 1 x M.2 3052, 1 x M.2 2280.
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7–16 (male)
85038M
-
Modern wireless communication systems require high-performance components offering low VSWR and low intermodulation distortion at high transmit power levels. To meet these needs, 7-16 connectors are becoming increasingly common in base station transmitters, amplifiers, duplexers, and other products. These connectors conform to IEC 169-4, DIN 47223, European standard EN 122190, and British standard BSEN 122190.
-
Product
3-in-1 OSL Mechanical Calibration Kit, DC To 50 GHz, 2.4 Mm (m)
85564A
-
The 85564A 3-in-1 mechanical calibration standard combines an open, short and load standard in a compact unit. The product is small, easy to handle, and lightweight. All standards in the 85564A are male 2.4 mm.
-
Product
Electronic Calibration Module, DC To 9 GHz, 2-Port
N7552A
-
Reduce your calibration time by half with a smaller, lighter 2-port module that supports 3.5 mm or type-N 50 Ω connectors
-
Product
USRP-2920, 20 MHz Bandwidth, 50 MHz to 2.2 GHz USRP Software Defined Radio Device
781906-01
-
20 MHz Bandwidth, 50 MHz to 2.2 GHz USRP Software Defined Radio Device - The USRP‑2920 is a tunable RF transceiver with a high-speed analog‑to‑digital converter and digital‑to‑analog converter for streaming baseband I and Q signals to a host PC over 1 Gigabit Ethernet. You can also use the USRP‑2920 for the following applications: white space; broadcast FM; public safety; land-mobile, low-power unlicensed devices on industrial, scientific, and medical (ISM) bands; sensor networks; cell phone; amateur radio; or GPS.
-
Product
Flexible Cable, 3.5 Mm (Test Port) To 3.5 Mm
85131H
-
The Keysight 85131H is a 62.2 cm (24.5 in) long1 flexible cable with a 3.5 mm female2 to 3.5 mm male connector. Cable frequency range is dc to 26.5 GHz with a return loss greater than or equal to 16 dB. Insertion loss is 0.25 * sqrt (f) + 0.2 dB (where f is frequency is GHz) for the test port connector, and 1.5 dB at maximum frequency for the device connector. Phase stability of semi-rigid/flexible cables is characterized with a 90 degree bend using a 3 inch radius. Stability1 of the Keysight 85131H is less than 0.12 dB and phase is 0.13o * f + 0.5o, (where f is frequency in GHz).
-
Product
1 Mm Calibration Kit
85059B
-
The Keysight 85059B is a 1.0 mm calibration kit designed for vector network analyzer systems operating over the frequency range of DC to 120 GHz. The opens, shorts and loads in this kit are optimized to provide accurate and traceable calibrations over the specified frequency range. The 85059B with 85059V 1 mm Verification kit are replacements for the 85059A 1 mm calibration/verification kit.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 3.5 Mm, 2 Port
85093D
-
The Keysight 85093D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
USRP Software Defined Radio Device
-
The USRP Software Defined Radio Device is a reconfigurable RF device that includes a combination of host-based processors, FPGAs, and RF front ends. The USRP Software Defined Radio Device include options that range from lower cost options with fixed FPGA personalities to high-end radios with a large, open FPGAs and wide instantaneous bandwidth. These devices can be used for applications such as multiple input, multiple output (MIMO) and LTE/WiFi testbeds, SIGINT, and radar systems.
-
Product
Standard Mechanical Calibration Kit, DC To 7.5 GHz, 7-16 (female)
85038F
-
The Keysight 85038F calibration kit contains only female calibration devices (open circuit, short circuit and termination) and has frequency coverage from dc to 7.5 GHz (usable to 8 GHz).
-
Product
I-Pi OSM Development Kit Based On NXP® I.MX 93 Dual-Core Arm® Cortex-A55 & M33
I-Pi OSM IMX93
-
The I-Pi OSM IMX93 is an OSM-based smart solution development kit powered by NXP i.MX93 (dual-core Arm Cortex-A55 & Arm Cortex-M33) processor with an in-SoC Arm Ethos-U65 microNPU (Neural Processing Unit).
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 7.5 GHz, 7-16, 2 Port
85098D
-
The Keysight 85098D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
Product
4-in-1 OSLT Mechanical Calibration Kit, DC To 18 GHz, Type-N (m) 50 Ohm
85518A
-
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit
-
Product
4-In-1 OSLT Mechanical Calibration Kit, DC To 18 GHz, Type-N (f) 50 Ohm
85519A
-
Easily calibrate non-insertable devices with this module combining an open, short, load, and through in a compact unit





























