Filter Results By:
Products
Applications
Manufacturers
-
product
Pt RTD Temperature Monitor
SIM923
Stanford Research Systems, Inc.
The four channels in the SIM923 have independent, stable 1 mA current sources to provide sensor excitation. Sensor resistance is determined ratiometrically with a half-bridge circuit consisting of the sensor and an internal reference resistor.
-
product
Dual MAX31865 PT-1000 RTD to Digital Breakout
SEN-30202-PT1K
Dual channel breakout board for the MAX31865 RTD-to-Digital converter from Maxim. Two breakout hardware configurations are available standard, designed to interface with either the PT100 or PT1000 platinum RTDs. For non-standard applications, including thermistors, custom hardware configurations can be accommodated. Contact Technical Support for more information.
-
product
Dual MAX31865 PT-100 RTD to Digital Breakout
SEN-30202-PT100
Dual channel breakout board for the MAX31865 RTD-to-Digital converter from Maxim. Two breakout hardware configurations are available standard, designed to interface with either the PT100 or PT1000 platinum RTDs. For non-standard applications, including thermistors, custom hardware configurations can be accommodated. Contact Technical Support for more information. RTD devices may be wired in 2, 3 or 4-wire configurations using the 4-pin screw terminal input. The MAX31865 breakout is interfaced via 3 or 4-wire SPI with a data-ready output for specific operating modes. An LDO and a high-speed level shifter are included to allow interfacing with microcontroller devices between 3.0V and 5V (all Arduinos, Raspberry PI, etc) without sacrificing device performance.
-
product
CT PT Tester
HTFA-109A / 343
Wuhan Huatian Electric Power Automation Co., Ltd.
Designed for automatic testing of CT/PT, it is suitable for laboratories and also suitable for field testing.
-
product
RTD Thermometers
Automatic, positive implied, negative polarityindication.Low battery indication: The “ ” is displayed when thebattery voltage drops below the operating level.Measurement rate: 1 times/second.Operating environment: 0°C to 50°C at<70% R.H.Storage temperature: -20°C to 60°C, 0 to 80% R.H. withbattery removed from meter.Accuracy: Stated accuracy at 23°C±5°C, <75% R.H.Battery: 1.5Vx4pcs AAA size.Dimensions: 160mm(H) x 83mm(W) x 38mm(D).Weight: approx. 255g including batteries.
-
product
CT PT Tester
HTFA-109 / 342
Wuhan Huatian Electric Power Automation Co., Ltd.
Used for automatic testing of protective and metrological CT/PT.
-
product
CT PT Tester
HTFA-103 / 335
Wuhan Huatian Electric Power Automation Co., Ltd.
Used for automatic testing of protective and metrological CT/PT.
-
product
RTD Thermometers
Precision Platinum Temperature Sensor, High Accuracy With 0.01°C Resolution, Automatic Locked Push-pull Connector For Easy Connection, Large Back Light LCD
-
product
Calibrator RTD Process Calibrator
VA720
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Calibrator RTD calibrator Source and measure 7 RTD type devices ( PT10, PT50, PT100, PT200, PT500, PT1000(385), PT100(JIS)).
-
product
RTD Temperature Indicator
CM2-TR
CM2-TR RTD Temperature Indicator has been designed in simple operation and 4 digital 20mm LED display with economic cost.They are can be programmed by buttons that are hidden in front panel.They are also available to option relay output and an analog output or RS485 (Modbus RTU Mode) communication.
-
product
8 Channels, RTD Measurement
RT1
The module provides 8 measurement channels, and can be programmed for interfacing to 2, 3, and 4-wire platinum RTD sensor configurations. The 4-wire mode (default) is the most accurate, providing excellent stability and repeatability. The RTD channels feature individual A/D converters and precision excitation/current drive. Programmable lead-wire compensation is provided for inherently less accurate 2 and 3-wire configurations. All RTD channels are self-aligning because each channel is automatically "aligned" on a rotating basis to eliminate offset and gain errors throughout the operating envelope. Programmability for expected resistance range and wire modes allows for optimization of scaling/resolution, as well as flexibility in reading many RTD types.
-
product
CT / PT Analyzer
CTPTA-504
UDEYRAJ ELECTRICALS PRIVATE LIMITED
UDEY ‘CTPTA-504 is a comprehensive CT and PT analyzer. It’s constant voltage and current is highly stable. DSP system controls the constant voltage and current source output and amplitude. This source generates AC of 0-125V and or DC of 0-0.5A current to sample CT. The DSP system besides controlling the sources, also samples data and communicates with the internal computer. Display screen is large LCD with touch pad. The analyzer is highly accurate with high noise immunity and is very user friendly.
-
product
RTD Alarm Setter Transmitter
Model TAR
Kusam Electrical Industries Limited
• 4 Digits Display For Input Signal:100.0 - 400.0 • Display - 100~400 °C / 100~700 °F • Output Signals Are Programmable. • Ultra-thin Dimension, 27mm width. • Non-Combustible PC Case .DIN Rail or Wall Mounting. • High Dielectric Strength ( AC 2KV / Min , Input / Output / Power )
-
product
CT & PT Test Kit
PCT200i
PCT200i is specially designed for current transformer characteristic test.This CT analyzer can finish the measurement class CT and TYP class CT.The additional functions include ratio and angle differential tests (the measurement points in the GB standard),FS and inductance,steady-state parameters,peak error and transient parameters,etc.
-
product
CT PT Tester
HTFA-107A / 341
Wuhan Huatian Electric Power Automation Co., Ltd.
Used for automatic testing of protective and metrological CT/PT.
-
product
RTD Measurement for VMEbus
VME390
The VME390 features 24 two, three or four wire high-accuracy PT100 measurement channels. Each channel has programmable alarm limits on which an interrupt can be issued.
-
product
CT PT Tester
HTFA-103A / 336
Wuhan Huatian Electric Power Automation Co., Ltd.
Used for automatic testing of protective and metrological CT/PT.
-
product
RTD Sensors
Are sensors used to measure temperature. Many RTD elements consist of a length of fine wire wrapped around a ceramic or glass core but other constructions are also used. The RTD wire is a pure material, typically platinum, nickel, or copper.
-
product
Strain Gauge and RTD via Ethernet
2612
Simultaneous measurement of four strain gauges or RTDs6 or 4-wire measurement with 200 nV resolution at a 6 Hz rateAuto-calibration cycle measures excitation at remote strain gaugeCompatible with Linux and WindowsUse our design assistant to configure a system and calculate pricing
-
product
Mineral Insulated RTD / RTD Probe With Extension Lead
Mineral Insulated Resistance Thermometers are for use up to 500°C depending on the configuration. They are rugged, steel sheathed probes with flexible sheaths allowing bending or forming. They offer long life (depending on use) are resistant to vibration
-
product
CT PT Tester
HTFA-105 / 337
Wuhan Huatian Electric Power Automation Co., Ltd.
Used for automatic testing of protective and metrological CT/PT.
-
product
PXI RTD Simulator Module, 20 Channel, PT500
40-263-102
The 40-263-102 is a 20-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
product
Dual Relay Trip Amplifier for RTD and Slidewire Sensors
SEM1633
The SEM1633 provides an accurate alarm / switching function when used with RTD or Slidewire sensors. Other sensor characteristics or your own 22 point linearization characteristic (for slidewire or linear resistance) can be downloaded into the product enabling you to adapt it exactly to your application.
-
product
PXI RTD Simulator Module, 8 Channel, PT500
40-263-402
The 40-263-402 is an 8-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
product
PXI RTD Simulator Module 18 Channel PT100
40-262-001
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the design principles of our 40-260 PXI Precision Resistor, this RTD simulator module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels.
-
product
Platinum and Nickel RTD Temperature Sensors
Accurate, repeatable and robust resistance temperature detector (resistance thermometers) sensor assemblies manufactured provide fast temperature response and can be applied in most temperature measurement and control applications.
-
product
Portable CT Analyzer With PT Testing
GF1061
Beijing GFUVE Electronics Co.,Ltd.
GF1061 portable ct pt analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT.
-
product
PXI RTD Simulator Module, 4 Channel, PT500
40-263-502
The 40-263-502 is a 4-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
product
PXI RTD Simulator Module, 24 Channel, PT500
40-263-002
The 40-263-002 is a 24-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
product
PXI RTD Simulator Module 6-Channel PT100
40-262-101
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.