Shielding
Protects against or confines electromagnetic or ionizing radiation.
See Also: Shielding Effectiveness
-
Product
Shield Level / Pathloss Equipment
PAMS & PAMS-C
-
PAMS is a user-friendly, transmitter and receiver system that measures shielding effectiveness in RF shielded enclosures. Lightweight and compact, each PAMS unit measures approximately 12” x 5” x 5” and weighs 5.5 lbs., making PAMS ideally suited to field measurement tasks. Rugged construction insures instrument survivability in a field test environment. PAMS-C is a simple and efficient solution for quickly identifying shielding faults in an RF shielded enclosure. Cousin to the original PAMS used extensively by customers operating RF Shielded Enclosures, PAMS-C gives commercial end-users everything needed to measure shielding effectiveness levels of critical infrastructure - all with minimal or no interruption to normal operations.
-
Product
Mini Digital Clamp Tester (CE)
M-140HC
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Easy!:Measurale Load Current at high voltage CV/CVT cables with grounding lines for shield phase.*Epoch-Making!:Can measure phase current of CVT cable just by putting CT head on to the conductors as well as CV cable just by clamping CT to the conductors in a lump.*Low Cost!:Can measure line/leakage current in the same manner as ordinary clamp meters.
-
Product
RF Shielding Services
-
LBA offers complete architectural RF shielding capabilities, including RF shielding for communications, medical and other radio frequency interference sensitive facilities. LBA is a major provider of architectural shielding solutions for buildings, laboratories and other spaces. LBA also offers other RF shielding materials, such as paints, fabrics and faraday cages, as well as an integrated line of shielding components to provide a comprehensive shielding system.
-
Product
Shield
Arduino MKR IMU Shield
-
The MKR IMU Shield is based on the BNO055 absolute orientation sensor from Bosch Sensortec GmbH which integrates a triaxial 14-bit accelerometer, a triaxial 16-bit gyroscope with a range of ±2000 degrees per second and a triaxial geomagnetic sensor with a 32-bit microcontroller running the BSX3.0 FusionLib software. The sensor features three-dimensional acceleration, yaw rate and magnetic field strength data each in 3 perpendicular axes.
-
Product
Coax, Contact, Receiver, 75 Ohm HD, sm59/U Belden 1855A, 3 GHz
610102133
Coax Contact
Primary mating contact 610102132. (May mate with other ITA contacts, as well.)Mechanical SpecificationsDurability 20,000 cyclesContact Material Female & Male Shield – BrassCenter Contact – BeCuContact Plating Center Conductor Shield – 30µ” Au over 100µ” NiContact Termination Center Conductor - SolderShield - CrimpInsulator PTFEMating Force 2.0 lbs max [0.91 kg]Electrical SpecificationsCharacteristic Impedance 75 ΩFrequency Range DC to 3 GHzVSWR ≤ 2.26 @ 3 GHzInsertion Loss -0.86 dB MaxDWV 1500 VDC min.Contact Resistance 5 mΩ center/ 3 mΩ outer Cable Specifications sm59/U Belden 1855AEnvironmental SpecificationsOperating Temperature -55°C to +125°CVibration MIL-STD 1344, Method 2005, Test Condition 4Shock MIL-STD 1344, Method 2004, Test Condition EInsulation Resistance 1000 MΩ min.
-
Product
AC/DC Clamp Meter
3801 CL
-
Standard Electric Works Co., Ltd
● Full auto range for V.A and Ω functions.● LCD backlight display.● Flashlight function.● Data hold function freezes the reading in dimly lit or hard to reach places.● Low battery indication.● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal parts. Shielded banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays transformers and motor coils.
-
Product
Line Tester
CAT 1 TEST
-
Monacor International GmbH & Co.
Line tester for continuity testing of Cat 5, Cat 6 and ISDN network cables*Connection test with LED display for 8 individual wires and shielding*Continuity, miswire, open, short, crossover, and ground detection*Connector compatibility with the following modular plugs: RJ45 (8P8C), RJ12 (6P6C), RJ11(6P4C, 6P2C)*Network standards supported: Token Ring, 10Base-T, 10Base-T2, 285A, TIA568A/568B*Separate receiver for particularly long and complex cables*The main unit and separate receiver can be attached to one another using a guide rail on the side*Power supply via 9 V block battery (not included)*Supplied with protective bag
-
Product
Rackmount Test Enclosure, ≥100 DB Isolation, 300 MHz - 18 GHz
dbSAFE RME
-
RF enclosures are now a necessity for testing wireless devices. The rackmount dbSAFE RME offers unmatched isolation in its class; up to 100 dB* from 300 MHz to 18 GHz. The dbSAFE RME has been engineered from the ground up to provide superior RF isolation and performance while being cost-effective. This premium isolation shielded box can be designed and manufactured to almost any size and dimensions.
-
Product
Hand-In Type Electromagnetic Anechoic Box (Shield Box)
MY3710HS
-
Higher shielding performance than MY371080dB. Suitable for weak electric field resistance test, out-of-service test or digital forensics for mobile phone, smart phone or tablet terminal! DUT can be operated directly with bare hands while placing it in the box and looking at the inside from the shield window.
-
Product
RF Shielded Chamber
MIL-STD
-
A high performance RF-shielded chamber specifically designed for radiated emissions testing in accordance with MIL-STD-461E/F. This chamber can be used for conducted emissions, conducted immunity, radiated emissions, and radiated immunity testing.
-
Product
RF Shield Box
LTL R21001
-
Liveon Technolabs LTL R12001 RF Test Enclosure is the streamline solution to manage your RF Testings. LTL R12001 RF shielded test enclosure can comfortably house the intermediate and large devices on test such as Laptops, larger test Fixtures and other large RF devices.
-
Product
Near Field Probes 30 MHz up to 6 GHz
XF1 set
-
The XF1 set of near field probes consists of 4 passive near field probes and one passive E field probe for making measurements in the development phase of the magnetic and electric fields in ranges from 30 MHz to 6 GHz. Due to their integrated impendance matching, the probes are less sensitive in the lower frequency range than the RF type probes. The probe heads of the XF1 set allow for the step by step identification of interference sources of the magnetic field on an electronic assembly. At first, for example the XF-R 400-1 detects the fields which the assembly emits in total. Next, using higher resolution probes the interference sources can be more precisely detected. The E field probe is used for the detection of electric interfering fields near the assemblies. With trained use of the near field probes, field orientation and field distribution can be detected. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They have an internal terminating resistance.
-
Product
48-Ch SPDT 1A-100VAC 24VDC Switching
YAV91074
Relay
The YAV90074 module contents 48 SPDT Relays independent. Each relays PCB contact track is shielded individually in order to handle very low voltage signals and audio signals with extremely low crosstalk. The build-in power supply includes two extra filters to reduce the DC voltage ripple to the relay coils; the control tracks have been drawn in quadrature with signal ones, reducing the inductive coupling produced by the transient current.
-
Product
SH68M-68M-EPM, Male 68 pin SCSI to 68 pin VHDCI, 0.3m
192288-0R3
Multifunction Cable
68-Pin Male VHDCI to 68-Pin Male VHDCI, Twisted Pair, Shielded Multifunction Cable - The SH68M-68M-EPM Cable, sometimes referred to as SHC68-C68-EPM, connects DAQ devices. The cable includes separate digital and analog sections, individually shielded twisted pairs for analog inputs, individually shielded analog outputs, and twisted pairs for critical digital I/O. The SH68M-68M-EPM Cable is offered in different lengths.
-
Product
Clamp on AC Leakage Current Sensors
-
High Accuracy Clamp AC Leakage Sensor use permalloy magnetic cores, with small size, high accuracy, good stability, strong anti-interference ability characteristics. It is applied with double shield technology, which insure strong anti-interference ability.
-
Product
Near Field Probes 30 MHz up to 3 GHz
RF2 set
-
The RF2 near field probe set consists of 4 passive near field probes for measurements in the development phase of the magnetic field in the range from 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF2 set allow the step by step localization of interference sources of the RF magnetic field on assemblies. From greater distances the electromagnetic interference can be detected by RF-R 400-1 and RF-R 50-1 probes. The RF-B 3-2 and RF-U 5-2 probes with their higher resolution can more precisely detect the interference sources. Field orientation and field distribution on an electronic assembly can be detected through a trained special use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.
-
Product
Car-to-X Signal Strength Emulator
-
Qosmotec Software Solutions GmbH
QPER-C2X is a special adaptation of the signal strength emulator QPER, designed for mobile and Vehicular Ad-hoc Networks (MANet and VANet). Every radio devices in such an infrastructure-less network acts as a sender, receiver, and forwarder (router). Therefore, the ports of the QPER-C2X hardware are fully connected with each other by dynamically controllable attenuators. The system is fully designed for frequencies up to 6 GHz, since wireless communication for Intelligent Transport Systems (ITS) is based on the WLAN standard IEE 802.11p from 5.850 MHz to 5.925 MHz. The connected ITS stations can be either on-board units, as they are built into cars, or road side units that are used by road infrastructure (traffic lights, road work area delimiters, velocity signs). For tests in the lab, radio modules of such ITS stations are each kept in a shielding box that prevents any unwanted radiation over the air.
-
Product
Signal Conditioning Carrier
ProDAQ 5720
-
The ProDAQ 5720 Signal Conditioning Unit provides power and cooling for up to two Signal Conditioning Cards from the ProDAQ 58xx Series. These Signal Conditioning Cards provide conditioning for 8 or 16 channels and can be used directly with Bustec’s high-performance ProDAQ ADC function cards such as the ProDAQ 3416 16-ch. Sigma-Delta ADC Function Card or the ProDAQ 3424 8-ch. Sigma-Delta ADC Function Card.To connect the function cards to the signal conditioning cards SCSI-style cables from the ProDAQ 8010-Bx Series are used. They provide shielded twisted pair connections for signals and control.
-
Product
Research & Industry
XPERT 20
-
A small focal spot x-ray source provides increased visibility and sharpness of detail. With an X-ray source of up to 25kV and 1.0mA, the XPERT 20 provides images with the highest resolution to locate the smallest detail. Designed for use in the most limited spaces with complete shielding and other radiation safety features, the XPERT 20 is fully compliant with U.S. Federal and State requirements for radiation safety and operates with only a standard AC power source.
-
Product
Antennas
-
The PLA-R and PLA-T are active, battery powered receive and transmit loop antennas for the frequency range 9 kHz - 30 MHz intended for radiated emission testing (PLA-R) and site validation: Normalized site Attenuation, Shielding Effectiveness (PLA-SET consisting of PLA-R and PLA-T)
-
Product
SHC68-NT-S, 68-Pin VHDCI Female to 68-Pin Bare Wire Male Multifunction Cable
189041-02
Multifunction Cable
SHC68-NT-S Shielded Cable for 7831R boards, 68-pin VHDCI to unterminated, 2m
-
Product
Standard VXI Module Shield Kits Without Address Switch Opening
-
* Single-slot kit fits all VXI-1 Revision 1.0 to Revision 3.0 chassis.* Same design described above but without the address switch opening.* Complimentary layout support includes PCB design template and CAD layout files.
-
Product
Multi-Conductor Cables
-
16 Channel, multi-conductor cables are shielded and wired for PCB® equipment specifically. Shielding minimizes noise when located near other power or signal cables. Custom versions are also available on request. Instrumentation-grade BNC / DB-50 connectors are provided to interface with Patch Panels and Signal Conditioners.
-
Product
SH68M-68M-EPM, 68-Pin Male VHDCI to 68-Pin Male VHDCI, Twisted Pair, Shielded Multifunction Cable
190233-01
Multifunction Cable
68-Pin Male VHDCI to 68-Pin Male VHDCI, Twisted Pair, Shielded Multifunction Cable - The SH68M-68M-EPM Cable, sometimes referred to as SHC68-C68-EPM, connects DAQ devices. The cable includes separate digital and analog sections, individually shielded twisted pairs for analog inputs, individually shielded analog outputs, and twisted pairs for critical digital I/O. The SH68M-68M-EPM Cable is offered in different lengths.
-
Product
RF Shielded Fixture
-
A semi-automatic, pneumatically operated fixture with a sliding pressure top provides a very short mechanical cycle-time. The unit is prepared for full, multi-station automatic operation using a centrally placed robot arm for UUT load/unload.
-
Product
Micro Coax, Contact, Receiver, RG316 Double Shield
610140104
Coax Contact
Primary mating contact 610141104. (May mate with other ITA contacts, as well.)Mechanical SpecificationsDurability 10,000 cyclesContact Material Center Conductor – BeCuShield – BrassContact Plating 50µ" Au over 100µ" NiContact Termination Center Conductor – SolderShield – SolderInsulator PTFEMating Force 1.5 lbs max [0.68 kg]Electrical SpecificationsCharacteristic Impedance 50ΩFrequency Range DC – 10.5 GHzVSWR 1.0225 +.05 f(GHz)Insertion Loss -√f(GHz) x .06 dBDWV 800 V RMSContact Resistance 6 mOhms center/4 mOhms outer Cable Specifications RG316 Double ShieldEnvironmental SpecificationsOperating Temperature -65°C to +125°CVibration MIL-STD 202, Method 204, Test Condition DShock MIL-STD 202, Method 213, Test Condition IInsulation Resistance 2000 MOhms Min.
-
Product
Partial Discharge Measurement System
DAC-6021
-
DAC-6021 is a measurement system for testing Partial Discharge of high frequency equipment, power devices, stator coils, etc.Since the system combines Partial Discharge Measuring Instrument (DAC-PD-3) with Testing Corona-free Variable Frequency Voltage Source (DAC-WT-50) and Testing Shielded Chamber, most external noises are removed, and the measurement is safe.
-
Product
Arduino CAN Shield
IFB-10003-ANP
-
CAN (Controller Area Network) communication has become ubiquitous in industry. It is used in automotive applications (part of OBD and many other datalinks), on-highway trucks (J1939), industrial machinery and instrumentation, and equipment applications (factory automation). This shield is designed to provide a CAN 2.0 front-end interface for 5V Arduino modules (Uno, Mega, etc). The module uses SPI to communicate to the Arduino, and requires an aditional chip select pin. An optional interrupt line to the MCP2515 and two LEDS are also provided. The chip select and interupt lines are selected via zero ohm resistors and have several configuration options for flexibility stacking additional shields. A set of stackable headers is included with this board, not installed. An optional on-board voltage regulator may be used to supply 7.5V to the Arduino's 'Vin' pin (which is regulated to 5V by the Arduino's on-board LDO). The CAN shield regulator supports a wide input range of 9V to 32V. This makes it possible to cleanly build a stand-alone CAN node (remote sensor) without the need for a separate Arduino power supply!
-
Product
Twinax, Contact, Receiver, 50 Ohms
610113144
Twinax Contact
For increased reliability and to eliminate the need for polarization, the design of VPC’s Twinax contact consists of two concentric inner conductors for termination to a twisted pair, and an outer shield for termination of the cable shield.
-
Product
Autoinjector Testing System
-
Instron’s Autoinjector Testing System is designed to perform full functionality testing on a wide variety of drug delivery devices, including safety syringes and both needle shield and button-activated formats. Developed in collaboration with pharmaceutical manufacturers and CDMOs, the system captures essential performance requirements such as activation force, injection time, dose accuracy, needle depth, and click detection. It supports compliance with international standards like ISO 11608 and can be configured for integration with collaborative robots to enhance automation and throughput.