Breaker Locators
match a circuit to a breaker.
-
product
Vehicle Mount Cable Fault Location System
Weshine Electric Manufacturing Co., Ltd
VS2088Plus Built in Booster And Capacitor In Vehicle Underground Cable Fault Test Device
-
product
Cable Fault Locator
TX2001
Lowest Cost Full Specification Professional Graphical TDR Rugged Palm Top Design 350g (12oz) 5 Measurement Ranges up to 3000m (10,000ft) 50, 75 & 100 ohm Selectable Impedance Built in Tone Generator for Pair Tracing & Identification Suitable for testing all Communications Cables Water & Dust Proof to IP54 Complete with tool-belt holster & test leads
-
product
Cable Locator (LCD type)
5500 CB
Standard Electric Works Co., Ltd
● The 5500 CB transmitter is a great tool for locating and identifying cables and individual conductors. ● Designed for locating unenergized cables and powered cables. ● Voltage measurement for cables : ACV 12V~300V DCV 12V~300V ● Signal Transmission • Transmission Power Level Selection (includes 1, 2, 3) • Transmission Signal Code Selection (includes F, E, H, d, L, C, O, A) ● Flashlight & Back Light function.● The Silent Mode (Disable Button Beep).● The Level Bar Display on the LCD Screen (the transmission power level indication).● The Action Wave Display on the LCD Screen (when the signal is transmitted).● Auto power off function.
-
product
Precision Cable Locator Range
Radiodetection’s precision locators are designed for optimal locate performance for damage prevention professionals working in all industries and utilities.
-
product
Visual Fault Locator
Shanghai Baudcom Communication Device Co.,Ltd.
This Pen-type VFL is specially designed for field personnel who need an efficient and economical tool for fiber tracing, fiber routing and continuity checking in optical networks. It finds breakpoints, poor connections, bending or cracking in fiber optic cables
-
product
Circuit Breaker Identifiers
188 FFF
Standard Electric Works Co., Ltd
● The 188FFF doesn't have the function of the sensitivity adjustment. If the customers need the sensitivity adjustment function, plase refer to other models.● The 188FFF is a Fuse and Fault Finder which comprises of two parts : The Receiver and the Transmitter.● The Transmitter, draws a current from the mains supply circuit to which it is connected to. The Signal● Current from the Tx is at about 10kHz. The Transmitter is powered by the mains and requires no batteries.● The 10kHz signal current generated by the Transmitter is then searched(sniffed) by the Receiver to detect the Fuse, Circuit Breaker or the faulty circuit.● The Receiver is a tuned circuit which has it's center frequency tuned to about 10kHz. The sensor is located in the tip of the Receiver.● The amplitude of the received signal is shown on a bar-graph type Leds.● The more Leds ON, the stronger the signal.
-
product
Visual Fault Locator
FFL-310-U
FFL-310-U Visual Fault Locator is equipped with a 650 nm high power visible laser diode,can be operated in -CW (continuous) or … MOD (1Hz modulation) mode. There is one LED indicator:with RED or GREEN light; the RED one shows the operating mode of the laser diode output signal, and the GREEN one indicates low battery level. FFL-310-U is designed in a card-size dimensions.
-
product
Circuit Breaker Time Interval Meter
Measuring contact timings is useful for finding the contact bounces and non-simultaneity of contacts. This helps in finding the possible electrical or mechanical defects in the circuit breaker contacts. Timing analysis also make it possible to detect incorrect mechanical adjustments and wear phenomena of the circuit breaker by measuring the differences between the fastest and slowest phases.
-
product
ACR ResQLink View 425 PLB (Personal Locator Beacon)
2922
Small but resilient, the self buoyant (floating) ResQLink View has been professionally engineered and tested to ensure it can withstand even the harshest elements. This buoyant Personal Locator Beacon requires no subscription for use and includes a digital display providing live status and GPS coordinates. Whether on land, at sea, or in the air, trust that the ResQLink’s satellite precision and military durability, puts rescue in the palm of your hands.
-
product
Primary Cable Fault Locating
Directional Impulse Detector
The Directional Impulse Detector ( D.I.D.) is a compact handheld detector used to locate primary cable faults by sensing the magnetic field generated by the current pulse from a high voltage discharge device (thumper). A meter deflection indicates the intensity of the received signal. No deflection indicates that you have walked beyond the fault or away from the cable.
-
product
Hazardous Location Sensors
S88
The S88 pH Sensors are one part of the Model S88 Intelligent Sensors product line. The S88 Sensors offering includes pH Sensors, ORP Sensors, Ion Selective Sensors, Dissolved Oxygen Sensors, Conductivity Sensors and Resistivity Sensors. The S88 sensors have two Universal Sensor Designs; Insertion/Submersion or Valve Retractable with flared end to prevent blow out. The standard S88 sensors have 316 Stainless Steel housings although various materials of construction are available to maximize sensor performance while minimizing cost of ownership. For other materials of construction request a quotation from the factory.
-
product
Underground Cable Fault Locators
Techno Instrumentation (India) Private Limited
Complete range of underground cable fault locators. Manufactured in India.Surge GeneratorsReflectometer(Pre-locator) - Cable fault distance locatorCable fault finder/pinpointerHigh Voltage Murray LoopDC high voltage testersCable fault locating van
-
product
GPR Utility Locating Tools
LMX100™
LMX100™ offers the perfect balance of depth penetration and resolution for accurate locating. Data is collected in Locate & Mark mode; this provides a real-time image in the field to identify utilities and mark their locations.
-
product
Split-box Pipe & Cable Locator
Weshine Electric Manufacturing Co., Ltd
Pipe Locator is specially designed to detect pipes, sondes, telecommunication lines buried utilities. This device may detect buried power cables, CATV cables, gas and water pipes, sewer lines, telephone cables, fiber optic cables with sheath, sondes, inspection camera transmitters. The Transmitter emits a signal.
-
product
Circuit Breaker Testing Equipment (SCOT Series)
SCOT MXP
SCOT MXP measures, displays and prints CLOSE, OPEN and CLOSE-OPEN time in various configurations. The MXP has a special mode to measure Pre-Insertion Resistor (PIR) closing time
-
product
Intrinsically Safe Smartphone for Mining Locations
Smart-Ex 01M
The new Smart-Ex 01M was developed and certified to be used in underground mining locations - one of the toughest workplaces in the world. This rough environment places extra importance on mobile workers equipment to help them complete their work while staying safe - the Smart-Ex 01M is the perfect device to withstand this adversity. With this advanced technology, everything which was once handled by paper, clipboards and huge staff costs causing delays, can now be handled by this intrinsically safe smartphone. The Smart-Ex 01M comes with the same and unrivalled features as the Zone 1 / Division 1 Smartphone, the Smart-Ex 01: Same performances, same features, same quality. Of course, it is also unlocked, can be used with dirty or wet work gloves and has a powerful battery for a long workday. However, it is important to know that the Smart-Ex 01M is a stand-alone device with an own mining certification. Therefore and because of certification reasons a yellow leather case is required in underground mining locations. The Smart-Ex 01M with an ambient temperature range from 0C to +50C is approved and certified for use in ATEX and IECEx Mining areas.
-
product
Circuit Breaker Analysis System
Weshine Electric Manufacturing Co., Ltd
1. Time measurement: 12 fracture intrinsic points, closing time, with the same period, phase with the same period.2. Reclosing measurement: each fracture closing - minute, minute - closing, minute - closing - minute process time, one minute time,one closing time, two closing time, gold short time, no current value.3. Bounce measurement: closing bounce time, bounce times, bounce waveform of each fracture, rebound amplitude of each fracture.
-
product
Emergency Locator Transmitters And Beacons
We offer a diverse line of Beacons in form factors that can be modified and ruggedized to meet your application, from Military to Commercial to Rotary.
-
product
Locate and Map Underground Utilities
UtilityScan DF
Geophysical Survey Systems, Inc.
UtilityScan DF incorporates our innovative dual-frequency digital antenna (300 and 800 MHz) and an easy-to-use touchscreen interface to view shallow and deep targets simultaneously in a single scan.
-
product
Electronic Circuit Breaker Unit
The CorePower® DC or AC Electronic Circuit Breaker Unit replaces conventional thermal mechanical circuit breakers and functions as both a breaker and a switch for controlling loads. By placing ECBUs closer to loads, aircraft manufacturers gain a significant reduction in wire weight, need fewer system components, and lower installation labor costs while increasing safety, efficiency, and reliability. This new smaller unit requires less space and provides more flexible mounting options.
-
product
Visual Fault Locators
Optical Wavelength Laboratories
OWL fiber optic visual fault locators (VFL) are specially designed to couple a maximum of optical energy into multimode and singlemode optical fibers by using a bright red fiber optic laser. Breaks, microbends, and other anomalies in optical fibers and connectors cause the intense bright red laser light to escape, thus revealing the presence of a fault. In addition to visual fault location, OWL VFLs can be used as a visual optical fiber identifier. A visual fiber optic identifier eliminates much of the guesswork during testing by identifying the fiber under test.
-
product
Circuit Breaker Testing
HAOMAI Electric Test Equipment Co., Ltd.
Circuit Breaker Testing is utilised to test the operation of each switching systems and the programming of the entire tripping structure.
-
product
Overhead Fault Location
Schweitzer Engineering Laboratories, Inc.
Overhead faulted circuit indicators include easy-to-spot displays to help direct line crews to the faulted line sections—enabling faster restoration of power and improved customer uptime.
-
product
Circuit Breaker Analyzer
CAT Standard Series
The CAT Standard series circuit breaker analyzers & timers are stand-alone or a PC-controlled digital instruments for circuit breakers condition assessments. The timing channels record closing and opening of the arcing, resistor, and auxiliary contacts. CAT Standard series records graphs of both, trip and close coil currents and displacements of the HV and MV circuit breaker moving parts. The main contact channels can also measure the resistance value of the pre-insertion resistors (if present in the circuit breaker). Test results can be downloaded to a USB memory stick or saved to internal memory. The CAT Standard series internal memory can store up to 500 test results (numerical and graphical data). Test results can also be printed on the 80 mm (3.15 inch) thermal printer (optional accessory) in tabular and graphical form. CAT Standard series provides an easy selection of different operational modes:
-
product
Pen-type Visual Fault Locator (VFL)
JW3105A
Shanghai Joinwit Optoelectronic Tech,co.,Ltd
JW3105A VFL is specially designed for field personnel who need an efficient and economical tool for fiber tracing, fiber routing and continuity checking in optical network. It includes:
-
product
Digital Circuit Breaker Analyzer
CT-8000 S3
The CT-8000 S3 is Vanguard’s fourth generation EHV circuit breaker analyzer. The CT-8000 S3 is available with 3 (part number 9103-UC) or 6 contact timing channels (part number 9104-UC). The CT-8000 S3 can fully analyze a circuit breaker’s performance by measuring the main contact and resistor contact time, stroke, velocity, over-travel, bounce back and contact wipes. Also, an outstanding feature of the CT-8000 S3 is the ability to perform dynamic resistance tests on circuit breaker contacts.
-
product
Cable Fault Locator ECFL 30
ECFL 30
Compact precision active/passive, AC/DC bridge with dual channelTDR for fault location on balanced loaded and unloaded cables.
-
product
Circuit Breaker Analysis Systems
When a fault such as a short circuit or current overload is detected by a protective relay, a trip impulse is sent to the circuit breaker. The circuit breaker must function as specified and interrupt the current as soon as possible or severe damage may occur. The damage caused by a malfunctioning circuit breaker can often be catastrophic, resulting in significant damage to the electrical system.
-
product
Interference Locating System
SeeWave®
Interference impacts wireless network coverage and quality of service, but hunting interference in the field can be expensive and time-consuming. PCTEL’s SeeWave® interference locating system enables a single user to accurately detect the interfering frequency and locate its exact source.
-
product
Circuit Breaker Test Equipment
DV Power has released a new generation of circuit breaker test equipment for condition assessment of medium and high voltage circuit breakers.Field-portable instruments with standalone or PC controlled functionality, allow performing various tests during circuit breaker manufacturing, commissioning and maintenance stages.Applications supported by the DV Power test equipment include measurements of:Contact resistanceDRM (dynamic resistance measurement)Coil resistance and coil current (IEC 62271-100)Mechanism charging time (IEC 62271-100)Minimum trip voltage (IEC 56, ANSI C37.09)Undervoltage release (IEC 60694)The timing of a circuit breaker’s main, auxiliary and pre-insertion contactsSynchronization between the contactsMotion and velocity“First trip” testThe essential part of a circuit breaker condition assessment is the ability to compare the latest test results with the previous testing. Accordingly, our instruments store measured values and compare them to a manufacturer’s limits. Also, a fingerprint obtained in this way can be used at a later stage as a reference during subsequent measurements. In order to obtain an accurate comparison, the tests need to be performed using identical test parameters. Consequently, any deviation and change in the test results may indicate the circuit breaker condition deterioration. Even more, to overcome this issue, DV-Win enables test plans and graph overlay features.Finally, as a final result of a circuit breaker maintenance process, the DV-Win provides analytical tools and customized report creations.





























