Arc Fault
unintended electrical discharge.
-
Product
PXI Fault Insertion / Signal Insertion Switch Modules
Switch Module
Pickering's PXI Fault Insertion / Signal Insertion Switch Modules feature a breakout arrangement that allows faults to be attached to the sensor lines, this includes the breaking of a connection or the adding of defect all of which can simulate connectivity problems in the system. Two switching topologies are available: *Single signal paths with series switches and switches to connect to one or more fault buses*Pairs of signals with series switches, shorting switches between the signal pairs and switches to connect either signal to an external fault input.
-
Product
HCAI-1 High Current Arc Ignition Tester
HCAI-1
-
The HCAI-1 High Current Arc Ignition Tester is according to IEC 60950-1:2001, BS EN 60950-1:2001, BS 7002:2000, GB 4943.1-2011
and UL746A, IEC60947.1: 1999, GB/T14048.1-2000, IEC730.1:1993, GB14536.1-2008 and other standards required simulated safety test project. Parts and components of insulating materials or other solid combustible materials that are prone to flame spread in electrical and electronic equipment may ignite due to proximity or contact with electric arc, causing electrical fire and endangering the reliable operation of equipment and personal safety. -
Product
PXI 10A Fault Insertion Switch 6-chan 2-bus
40-192-012
Switch Module
This PXI fault insertion switch uses solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test: Open-Circuit. Short-Circuit between UUT connections. Short-Circuit to external signals. Through relays on each channel enable signals to the UUT to be set open-circuit. Fault Insertion Buses allow any channel to be shorted to any other channel and also enable any channel to be connected to an external signal such as Power, Ignition or Ground to simulate fault conditions. The module is supplied with 2 fault buses.
-
Product
PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Single Channel
40-204-001
Multiplexer Module
The 40-204-001(PXI) and 42-204-001 (PXIe) are single channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault. Using the fault bus, switches can simulate a short between both wires or a short to one of two externally applied fault conditions – such as battery supply or ground - via two fault buses.
-
Product
Medical Box PC Featuring The 12th/13th/14th Gen Intel® Core™ I3/i5/i7/i9 Processors, With Support For MXM-AXe Based On Intel® Arc™ GPU, And Thunderbolt™ 4 Port
MLB-3102 with Intel MXM GPU
Industrial Computer
- ADLINK MXM-AXe graphics module support (type A, up to 50W TDP based on power supply)- 12th/13th/14th Gen Intel® Core™ i3/i5/i7/i9, Celeron® processor- Dual SODIMM for up to 64GB DDR5 non-ECC memory (depending on CPU)- 1x HDMI 2.0, 5x DisplayPort (1 from CPU, 4 from MXM)- 1x M.2 E-key supporting 1630 or 2230 for Wi-Fi/Bluetooth module, 1x M.2 M-key supporting 2242 or 2280 for SATA/PCIe storage module, 1x M.2 M-key supporting 2242 or 2280 for NVMe & frame grabber- Reliable Molex 24V DC-in connector- 2x 2.5GbE Intel® I225-LM Ethernet Controller- 2x PCIe Gen 3 x4 expansion slot for full-height, half-length add-on card, each slot is 25W power budget and additional Molex 4-pin power cable (12V/1.5A and 5V/2A) support
-
Product
Vector Network Analyzer 9KHz-3.2GHz. Includes Adv Meas Kit, Distance To Fault Opt, Cal and Utl Kits
T3VNA3200
Vector Network Analyzer
Vector Network Analyzer 9KHz-3.2GHz. Includes Adv Meas Kit, Distance To Fault Opt, Cal and Utl Kits.
-
Product
Voyager Intermittent Fault Detector
-
The Voyager includes a spread spectrum TDR so that the fault can be located. Once an intermittent is detected, the TDR is immediately connected to the failed test point and used to determine the distance to the fault.
-
Product
Fuse Circuit Breaker and Fault Finder
-
Shanghai Beha Electronics Co., Ltd.
*is a Fuse and Fault Finder which comprises of two parts: The Receiver and the Transmitter.*Locating and tracing of cables*Finding Circuit Breaker/RCD
-
Product
Detection of PtG and PtP Faults on Multi and Single Core Cables
CableTroll 2350
-
CableTroll 2350 is an indicator for detection of PtG and PtP faults on multi and single core cables. The unit uses standard type current transformers. (40:1, 60:1 or 3x500:1)
-
Product
Fault Location
REFLEKT
-
REFLEKT makes fault location more efficient, effective and practicable than ever before, even on complex networks.
-
Product
5mA High Accuracy Ground Fault Detector
HA-GFD
-
Our HA-GFD Current Probe is our most sensitive current probe, measuring down to 5 milliamps. Ideal for measuring leakage current and ground faults. Dual range allows measuring up to 200 amps in high accuracy.
-
Product
Visual Fault Locator VFL X5007
-
Metal case, Rugged and durableLow battery indication, to avoid leakage and wrong judgmentESD protection design, Protect the LD effectivelyIntegrated case, to avoid the case intermediate brokenRe-changeable ceramic tube, to avoid returning to manufacturer for this small faultLong battery life, up to 60 hours@1mW
-
Product
Travelling Wave Fault Location Test Kit
PH Series
-
PH series travelling waveform fault locating relay/equipment test set is a new device to meet the needs of testing and verification for travelling wave fault location equipment and protection relay with TWFL function.
-
Product
FAult Detector and OScilloscope 7 Functions in 1 Device
FADOS7F1
-
Prot-Ar-Ge Industrial Project Design R&D Ltd. Co.
Usage of FADOS7F1: Determining faults of all types of electronic cards such as electronic cards of medical devices, textile and any other machines; automobile electronics; computer, monitor, TV, etc. Electronic Components Test: IC, transistor, FET, IGBT, resistor, capacitor, indicator, ect. This device is used to determine the faults at all these electronic components.
-
Product
NI-9861, 1-Port, Low-Speed/Fault Tolerant C Series CAN Interface Module
781962-01
CAN Interface
1-Port, Low-Speed/Fault Tolerant C Series CAN Interface Module—The NI‑9861 is a fault-tolerant Controller Area Network (CAN) interface for developing applications with the NI‑XNET driver. The NI‑9861 is ideal for applications requiring real-time, high-speed manipulation of hundreds of CAN frames and signals, such as hardware‑in‑the‑loop simulation, rapid control prototyping, bus monitoring, automation control, and more. You can perform this manipulation while taking other data acquisition measurements in the same NI CompactDAQ hardware platform or while performing low-level FPGA control and embedded monitoring in the same NI CompactRIO chassis.
-
Product
Pipeline & Cable Fault Locator
TM2000
-
TM2000 Pipeline & Cable Fault Locator is designed for the Underground utilities route locating, the depth measuring and disatance tracing.
-
Product
Fault Locator
REZAP MODULAR
-
REZAP MODULAR brings full REZAP functionality to fuse panels with severe space restrictions
-
Product
Cable Fault Location System
Syscompact 2000 M Pro
-
Cable fault location system 2000 M pro. The portable BAUR Syscompact 2000 M pro cable fault location system is used for cable fault location and cable testing in low- and medium-voltage cables up to 65 km length.* Fully integrated proven cable fault pre-location methods* Surge mode for acoustic pin-pointing* Easily transportable* Ideal for locations that are difficult to access
-
Product
Visual Fault Locator VFL
X4007
-
X-4007 series visual fault locator is used for the measurement in single-mode or multi-mode fibers. It features a rugged design, a universal connector and an accurate measurement.
-
Product
Pen-type Visual Fault Locator (VFL)
JW3105A
-
Shanghai Joinwit Optoelectronic Tech,co.,Ltd
JW3105A VFL is specially designed for field personnel who need an efficient and economical tool for fiber tracing, fiber routing and continuity checking in optical network. It includes:
-
Product
Vehicle Mount Cable Fault Location System
-
Weshine Electric Manufacturing Co., Ltd
VS2088Plus Built in Booster And Capacitor In Vehicle Underground Cable Fault Test Device
-
Product
Ground Fault Monitor
IFT-120
-
Our ground fault monitors enable you to easily and quickly find the source of the fault before a major problem occurs and damages your equipment. This is the IFT-120, designed to assist you in rapid identification of ground faults.
-
Product
CAN/FlexRay/Differential Bus PXI Fault Insertion Switch - 4 Channel
40-200-004
CAN Interface
Each channel can support up to 0.3A and is rated to handle up to 100V between the wire pairs. The wire pairs have controlled transmission line impedance suited to most differential pair signaling systems, including fast CAN Bus interfaces and RS232. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
Product
Electrical DfT & Fault Coverage Analyzer
TestWay
-
TestWay's electrical DfT analyzer enables designers to validate designs at the schematic capture stage, to ensure that adequate measures have been included to comply with the manufacturers test requirements. The ability to verify that PCB designs have been developed with adequate Design-for-Test in mind, is key in determining the most effective test strategies and accurately calculating fault coverage, which is crucial in improving competitive advantage, lowering cost and ensuring product quality.
-
Product
Fault Locating
-
Schweitzer Engineering Laboratories, Inc.
The built-in fault-locating methods in SEL devices allow you to quickly identify faults, dispatch crews for repairs, and restore service faster. Traveling-wave fault-locating technology calculates the locations of temporary and permanent faults by measuring the arrival times of the naturally occurring traveling waves caused by a transmission line fault. Accurately detecting these waves requires ultra-high-resolution monitoring, and locating is accurate to within one tower span (±300 m). Impedance-based fault-locating technology calculates fault locations by detecting changes in line impedance as a result of a fault. Impedance-based locating is reliable and accurate to about 2 percent of a line’s total length.
-
Product
PXI Single Bus 32-Ch 2A Fault Insertion Switch
40-190B-201
Fault Insertion Unit
The Single Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
PXI/PXIe 1000Base-T1 Dual Multiplexer With Fault Insertion, Dual Channel
42-204-002
Multiplexer Module
The 40-204-002 (PXI) and 42-204-002 (PXIe) are dual channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault.
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
42-203-001
Fault Insertion Unit
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.