E Field Probes
measure E and H fields from KHz to GHz.
-
Product
3U 1-Slot OpenVPX P&G, Aperture E, VITA
101V301P03-9X12
-
3U 1-Slot OpenVPX Power & Ground, Aperture E, Supports VITA 66.4/67.3A/67.1 in J2B, Module Smiths Interconnect 415-00004, Pass through with VITA 66.4 ctr in J2B, w/o ROHS, Max data rate 10 Gbps.
-
Product
E & W-Band PIN Diode Waveguide Switches
-
Fairview Microwave’s single-pole single-throw (SPST) and double-pole double-throw (DPDT) PIN diode waveguide switches feature fully integrated WR-10 and WR-12 waveguide ports and cover popular E-band (60 to 90 GHz) and W-band (75 to 110 GHz) frequencies. Switch circuits integrate low loss Fin-line assemblies with high performance GaAs beam-lead diodes that results in 4 dB insertion loss, greater than 25 dB of Isolation and fast switching speed < 300 nsec.
-
Product
Magnetic Field Visualization
mageye
-
Our mobile "magnetic field sensor" allows you to visualize and evaluate magnetic stray fields. Our mageye, matesy’s miniaturized magneto-optical USB microscope, provides information about the magnetic fields on the surface of a wide variety of samples with resolutions in the micrometer range.
-
Product
Magnetic Field Camera: mapping for MRI applications
MFC2046
-
MRI and NMR spectroscopy applications require a highly uniform magnetic field, within at most a few ppm. NMR is the only magnetic measurement technique capable of providing a field map with that degree of precision. Introduced 25 years ago, Metrolab’s NMR Magnetic Field Cameras have revolutionized field mapping for MRI magnets. They reduced acquisition times from hours to minutes, positioning errors to fractions of a millimeter, and they rendered human and drift errors negligible. Now, meet the latest generation NMR Magnetic Field Camera, the MFC2046! Map any magnet with the New generation of MFC probe arrays. Magnetometer Teslameter Gaussmeter
-
Product
Probes, Magnetic Field
EM-6882 | 20 MHz To 230 MHz
-
The EM-6880, EM-6881 and EM-6882 Magnetic Field Probes operate in conjunction with any 50 ohm input impedance receivers.
-
Product
Ultra High 2.84 (81.00) - 10.00 (283.00) High Performance Lead Free Probe
LFRE-1B-10
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Field Strength Meters
FIM-22 And FIM-41
-
The Models FIM-22 and FIM-41 are portable field strength meters designed to provide precise, direct measurements of electro-magnetic fields in the 200 kHz to 5.0 MHz spectrum. These units include a receiver, integral shielded loop antenna, precision attenuator, internal calibration source, and battery power supply. With calibration accuracy traceable to the National Institute of Standards and Technology, the FIM-22 and FIM-41 meet the most exacting requirements of government and industry. Their hinged covers, on the rugged drawn aluminum cases, contain a loop antenna. Opening the cover to a vertical position connects the antenna terminals to the receiver via maintenance-free gold-plated contacts. An interlock switch prevents inadvertent battery discharge when the cover is closed.
-
Product
High 1.50 (43.00) - 9.60 (272.00) Long Travel Bead Probe
BPLT-1F-9.6
Bead Target Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,450Overall Length (mm): 36.83Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, High Spring: 350 mil / 8,89 mm
-
Product
7U 1-Slot OpenVPX P&G, Aperture E,
101V701P08-9X12R
-
7U 1-Slot OpenVPX Power & Ground, Aperture E, Supports VITA 2 x 66.4 Pass through with apertures in J6A & J6B, w/ROHS, Max data rate (Gbps) 10.
-
Product
POGO-1 High Performance Bias Ball Probe
POGO-1
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Super 3.90 (111.00) - 16.00 (454.00) High Performance Lead Free Probe
LFRE-25UN-16
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Passive Probes
-
Passive voltage probes ship standard with most oscilloscopes and provide a low cost, general purpose probing solution. Generally, these probes lack the performance of an active voltage probe but provide the ruggedness and wide dynamic range suitable for visualizing signals over a broad range of applications. Tektronix has released a new class of passive probes that redefine performance in the passive probe product category.
-
Product
ICT Probes
Merica Series-MPA75
-
Minimum Center: 1.91 (75mil)Current Rating: 3amps, continuousCurrent Resistance: 40milliohmsMounting Holes Size: 1.35Full Stroke: 6.35mmRated Stroke: 4.30mmSpring Force: 198gf(7oz)
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3L5
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25L-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Low E Coating Detectors
-
Single Pane Low E Coating DetectorDetect Low E Coatings on Single Pane GlassThe AE3600 Single Pane Low-E Detector checks both surfaces of single pane glass with one test from a single side. The AE3600 is optimized for testing.
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T135
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
3U 1-Slot OpenVPX P&G, Aperture E, VITA
101V301P02-9X12R
-
3U 1-Slot OpenVPX Power & Ground, Aperture E, Supports VITA 66.4/67.3A/67.1 in J2A+B, Pass through, w/ROHS, Max data rate (Gbps) 10.
-
Product
Prototype Performance Field Testing iOS app
-
Centric's new Field Testing app provides an innovative solution for product performance feedback. Centric's Field Testing App is an example of how capturing data live, in the moment, is not only incredibly valuable but also a natural way of working. This app helps reducing costs while also improving product innovation and performance; which are ultimately keystones of great brands.
-
Product
BMP-4 Board Marker Probe
BMP-4
ICT/FCT Probe
Current Rating (Amps): .020Voltage Rating (VDC): 12Recommended Duty Cycle: 2 sec. On (min.), 3 sec. OffTest Center (mil): 1,000Test Center (mm): 25.40Full Travel (mil): 79Full Travel (mm): 2.01Recommended Travel (mil): 50Recommended Travel (mm): 1.27Full Marker Travel (mil): 62Full Marker Travel (mm): 1.57Direction of Rotation: CCWScribed Diameter (mil): 50Scribed Diameter (mm): 1.27Test Center Remark: Ø .398 (10.1) or M10
-
Product
High 0.75 (21.00) - 8.00 (227.00) Long Travel Bead Probe
BPLT-25C-8
Bead Target Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
Product
Magnetostatic probe
BS13
-
Three-dimensional measurement of magnetic equationsMeasuring range 100 TResolution 0.1 TAbsolute and relative measurementsFor connection to the field meter FM10Switching between total field strength and X, Y and Z proportions is possiblePermanent recording and saving of individual points with the field meter FM10LOutstanding value for moneyDimension 132 x 40 x 25 mm
-
Product
Alternate 2.52 (71.00) - 6.50 (184.00) General Purpose Probe
EPA-3B-1
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Near Field Probes 30 MHz up to 3 GHz
RF1 set
-
The RF1 near field probe set consists of 4 passive near field probes for making measurements in the development phase of E-field and magnetic field in the ranges of 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF1 set allow for measurements close to the electronic assemblies, e.g. on single IC pins, conducting paths, components and their connectors in order to localize interference sources. Field orientation and field distribution on an electronic assembly can be detected through a trained special use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.
-
Product
Active Loop Antennas / Magnetic Field Probes
-
Is an active, shielded handheld loop antenna with nearly con- stant antenna factor over the entire frequency range. It can be used for testing according to CISPR, MIL, FCC, EN, ISO, ANSI, ETSI and many other standards.
-
Product
Magnetic Field Cancelling System
MR-3
-
3-axis magnetic field cancelling system for electron microscopes (SEM and TEM), electron and ion beam experiments, nanotechnology, biomagnetic investigations, etc. High reliability through rugged analog design. No tedious programming, no chrashs. More than 1000 MR-3 systems sold worldwide.
-
Product
Ruggedized Field Deployable Tester
PUMA
-
- 18-slot PXI / 4-slot SCXI Chassis- 1.2 GHz Embedded Controller- 4-axis Motion Controller/Simulation- 8-port RS-232 Serial Module- 4-port RS-485 Serial Module- 48 bit Isolated Digital I/O- Reconfigurable multi-function I/O FPGA Module- 5 1/2 digit DMM- 200 MHz 2-channel Scope/Digitizer- Multi-function Data Acquisition (DAQ)- 8-channel Analog Input Module- 6-channel Analog Output Module- General Purpose Switching- RF suite (optional)
-
Product
Microwave Probes
S-Probe
-
S-Probe series of single-ended probes can perform up to 20 GHz are designed for RF, power integrity, and signal integrity testing. Its strong beryllium copper (BeCu) tips is perfect for direct probing of uneven surfaces, such as solder pads and circuit components. This is a big improvement over the fragile microprobes.
-
Product
Mainframe or -E Expansion Chassis - Preconfigured Single or Two Pole Matrix Systems
LXB/128-MF
Chassis
These Chassis are preconfigured single or two pole matix systems. A single chassis can be a 16x8 matrix, two 16x4 matrices, a single 32x4 or a single 64x2 configuration. Chassis is modular so you may start with a smaller size and increase the configuration as your needs grow.