Current Probes
measure AC or AC-DC amperage without contacting conductors.
See Also: Current Sensors
-
Product
Standard -1.44 ( 41.00) - 4.50 (128.00)High Current Probe
HCP-13B
High Current Probe
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
I-V Measurement Systems
-
The I-V Curve Data Acquisition includes a fixture for holding cells for testing (see Figure 1 below). This fixture can accommodate cells from small to up to 100 mm x 100 mm. Adjustable cell stops, in the X & Y-axis, are provided to consistently locate the cells for testing. Two micro-manipulators are provided as shown in Figure 1. Each micro-manipulator has two spring loaded contacts to allow 4-wire measurement even for cells that have top contacts only. Two back-side voltage contacts are embedded in the Plate (galvanically isolated from the Plate) and make good electrical contact when the cell is held down by vacuum to the plate. All voltage and current probes are gold-plated. The cell is held down with vacuum during testing (built-in vacuum pump).
-
Product
CC30100X, 100 MHz, 30 Arms Current Oscilloscope Probe
785562-01
High Current Probe
The CC30100X, or Hioki 3276, is a clamp-on current probe that offers a wide DC to 100 MHz bandwidth and 30 Arms of continuous input. It is ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers. The probe requires an external power supply.
-
Product
Current Probe
PA-659
-
*Maximum Current Value: +/- 150ADC, 100A RMS*1mA = 5mA, 50mA (switchable)*Rising Time: 0.7uS*Bandwidth: DC ~ 500kHz*Over Range Indicator*Battery, AC Power Supply Adaptor (free), dual usages
-
Product
AC Current Probe 100 mV/A, 60A, 11 Hz LF Bandwidth, 5MHz HF Bandwidth, 1m cable
T3RC0060-LF
-
AC Current Probe 100 mV/A, 60A, 11 Hz LF Bandwidth, 5MHz HF Bandwidth, 1m cable.
-
Product
AC/DC Current Probe (2-Channel), 3 MHz, 50 UA
N2820A
Oscilloscope Probe
The N2820A 2-channel current probe connects to two oscilloscope channels to provide simultaneous low- and high-gain views for wider dynamic range measurement, while the N2821A 1-channel current probe provides one user-selectable view at a time.
-
Product
Constant Current System
CCS-BTA
-
Vernier Software & Technology, LLC
The Constant Current System is a DC power source with a built-in current probe designed for use in electrochemistry experiments.
-
Product
T3RC Rogowski Coil Current Probes
T3RC Series
-
Teledyne Test Tools Rogowski Current probes offer a broad range of products covering a wide frequency span and current measurement ranges for maximum application coverage whilst being easy to use in difficult to reach parts of the circuit.
-
Product
Photometric Radiometric Transmitters
HD2021T6 / HD2021T7
-
The transmitters allow converting the photometric quantity “equivalent veiling luminance” – HD2021T7 – or a photometric quantity Luminance (cd/m2) – HD2021T6 – into a current (4…20 mA) or a voltage (0…10 V) signal according to the version chosen. If the acquisition station is far from the probe (>50m), it is necessary to use the current output version.The probe is used for the control of street lighting, in particular, the measurement of equivalent veiling luminance is essential to determine the threshold luminance at the entrance of the tunnels (UNI 11095:2011).
-
Product
Spring Probes & Hyperboloid Contacts
-
In-Circuit / Functional Probes, Socketless X Probes®, High Current Probes, Double Ended Probes, ATE Interface Probes, integraMate®
-
Product
AC Current Probe 2 mV/A, 3,000A, 3 Hz LF Bandwidth, 23MHz HF Bandwidth, 4m cable, 200mm coil
T3RC3000-HF
-
AC Current Probe 2 mV/A, 3,000A, 3 Hz LF Bandwidth, 23MHz HF Bandwidth, 4m cable, 200mm coil.
-
Product
HPC High Current Probe
HCP-13
High Current Probe
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Current Probe
LFR
-
Power Electronic Measurments Ltd
The LFR is ideal for power quality applications. It has a small, predictable phase error, for power measurements at 45/65Hz. The wide bandwidth allows accurate measurement up to and even above the 400th harmonic.
-
Product
Brute High Current Probe
P4301-2F
High Current Probe
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
AC/DC Current Probe (1-Channel), 3 MHz, 50 UA
N2821A
Battery Probe
As modern battery-powered devices and integrated circuits become more green and energy efficient, there is a growing need to make high-sensitivity, low-level current measurements to ensure the current consumption of these devices is in acceptable limits. The N2821A high-sensitivity probe is engineered to make high-dynamic-range, high-sensitivity measurements to meet today’s challenging current measurement needs.
-
Product
Current Probe
-
Beijing GFUVE Electronics Co.,Ltd.
Used to measure control currents for relays in electronic circuits and in evaluation testing of capacitors' current characteristics.
-
Product
Current Probes | Current Sensors
-
Sensitivity of Conventional Probes Deliver Precise Measurement of Low Current Waveforms from 1 mA. High-precision Current Sensors, DC to 4 MHz, DC to 20 kHz, up to 50 kHz and load current sensors,
-
Product
Standard - 22.08 (626.00) - 220.80 (6259.60) Godzilla High Current Probe
HC500F
High Current Probe
Current Rating (Amps): 150Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 260Full Travel (mm): 6.60Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,215Overall Length (mm): 81.66
-
Product
Godzilla High Current Probe, 100 Amp
HC375
High Current Probe
Current Rating (Amps): 100Average Probe Resistance (mOhm): 25Test Center (mil): For more details, please contact us.Test Center (mm): For more details, please contact us.Full Travel (mil): 360Full Travel (mm): 9.14Recommended Travel (mil): 250Recommended Travel (mm): 6.35Overall Length (mil): 3,110Overall Length (mm): 78.99
-
Product
CC05120X, 120 MHz, 5 Arms Current Oscilloscope Probe
786847-01
High Current Probe
The CC05120X, or Hioki CT6701, is a clamp-on current probe that offers a wide DC to 120 MHz bandwidth and 5 Arms of continuous input. It is ideal for capturing transient current signals from switching power supplies, inverters, and motor controllers. The probe requires an external power supply.
-
Product
Brute High Current Probe
P4301-1Z
High Current Probe
Current Rating (Amps): 50Current Rating Remark: 40 Amps for BeCu plungersAverage Probe Resistance (mOhm): 5Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,750Overall Length (mm): 44.45
-
Product
AC Current Probe 50 mV/A, 120A, 34 Hz LF Bandwidth, 30MHz HF Bandwidth, 1m cable
T3RC0120-UM
-
AC Current Probe 50 mV/A, 120A, 34 Hz LF Bandwidth, 30MHz HF Bandwidth, 1m cable.
-
Product
AC / DC Current Probe, 100 KHz, 100 A
1146B
High Current Probe
The Keysight 1146B AC / DC probe provides accurate display and measurement of currents up to 100 A DC or peak AC / DC to 100 kHz without breaking the circuit. The 1146B AC / DC probe has hall-effect sensor technology to measure AC and DC signals. It is compatible with any Keysight oscilloscope with 0.2 to 0.5 V / div sensitivity and 1 MΩ BNC input.
-
Product
AC/DC High Sensitivity Clamp-On Current Probe
N7026A
Oscilloscope Probe
The Keysight N7026A is a 150 MHz bandwidth, active current probe for InfiniiVision and Infiniium oscilloscopes. The probe features wide and flat bandwidth (DC-150 MHz), lower noise (<250 µArms), and wide input range (up to continuous 30 Arms or non-continuous 40 Apeak). This enables you to measure down to 1 mA/div, giving you a much more accurate view of your low-level signals.
-
Product
Probes, Clamp-On
EM-6981 | 9 KHz – 110 MHz
-
Current probes enable you to measure conducted current without direct connection to the circuit under test by clamping around the conductor, current carrying wire or structural member being tested.
-
Product
Flexible Rope-Type Current Probe
RCT1A and RCT5A
-
These probes have great bandwidth ensuring accurate measurement even with harmonically distorted wave shapes. For all RCT1A/RCT models, a NIST, NAVLAP, NPL (UKAS) factory traceable calibration certificate and certificate of conformance is supplied. UL/CSA approved materials are used throughout. Three phase and single phase flexible AC current sensors (rope sensors) are available for fast installation in confined spaces, eliminating the need for Electrical Supply Shutdown. Available outputs are 1A @ 2.5VA and 5A @ 0.5VA, this means long cable lengths from current sensor to signal conditioner allow these low VA ratings to be used, even when feeder cable to energy meter distances are large (up to 98 feet / 30 meters)
-
Product
Complete Graphical Power Quality Analysis System
PK5064-PRO+
-
The PK5064-PRO+ is the top choice for comprehensive power quality studies, energy audits, load studies, harmonic analysis, and more. Wide-range flexible current probes allow you to get into tight and confined spaces, wrap around large conductors, and measure almost any AC circuit that comes your way.
-
Product
5 Amp High Accuracy Current Probe
HA5
-
Our HA5 Current Probe covers the measurement range from 20 milliamps to 5 amps, making it the best choice for measuring very small loads and the outputs of CT (Current Transformer) step-down circuits.
-
Product
Probe Kits
-
United Western Technologies Corp
UniWest Eddy Current probe kits combine multiple tools used in different NDT applications into one kit. Each field or airframe inspection kit provides all the probes you need for adequate testing.