RTD
- variable-resistance sensor measuring temperature by fluctuations in resistance.
-
Product
RTD Isolating Transmitter
Model TWR / TWR 2
-
Kusam Electrical Industries Limited
• Aux. Power AC 85 ~ 265V or DC 85 ~ 300V• High Accuracy 0.1% RO at 23 °C ± 5 °C• Input / Output User Selectable• PC Plastic Case, DIN Rail or Wall Mounting• High Dielectric Strength (AC 1.5KV/Min, between Input / Output / Power)
-
Product
RTD Sensors
-
Are sensors used to measure temperature. Many RTD elements consist of a length of fine wire wrapped around a ceramic or glass core but other constructions are also used. The RTD wire is a pure material, typically platinum, nickel, or copper.
-
Product
RTD / PRT Platinum Sensing Resistor Inserts
-
RTD / PRT Platinum Sensing Resistor Inserts - Ceramic Sheathed, Pt100 & Pt1000 Inserts
-
Product
RTD Alarm Setter Transmitter
Model TAR
-
Kusam Electrical Industries Limited
• 4 Digits Display For Input Signal:100.0 - 400.0 • Display - 100~400 °C / 100~700 °F • Output Signals Are Programmable. • Ultra-thin Dimension, 27mm width. • Non-Combustible PC Case .DIN Rail or Wall Mounting. • High Dielectric Strength ( AC 2KV / Min , Input / Output / Power )
-
Product
RTD Measurement for CompactPCI
CPCI390
-
The CPCI390 has a 3U form factor and features six 2-, 3-, or 4-wire high-accuracy RTD measurement channels. Each channel has programmable alarm limits on which an interrupt can be issued. The local DSP (TMS320C203) performs linearization, auto-calibration and alarm limit checking. Sensordata is available in °C, °F, K and Ohm. All inputs are optically isolated from the system.
-
Product
Pt RTD Temperature Monitor
SIM923
-
Stanford Research Systems, Inc.
The four channels in the SIM923 have independent, stable 1 mA current sources to provide sensor excitation. Sensor resistance is determined ratiometrically with a half-bridge circuit consisting of the sensor and an internal reference resistor.
-
Product
PXI RTD Simulator Module, 24 Channel, PT500
40-263-002
Simulator
The 40-263-002 is a 24-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
PXI RTD Simulator Module 18-Channel PT1000
40-262-002
Simulator
The 40-262 is a 3U PXI module range that supports 6 (in one slot), 12 or 18 (in two slots) channels of RTD simulation. Based on the 40-260 design principles the module can provide a setting resolution of <8mΩ (PT100) or <90mΩ (PT1000) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
Product
3-CH RTD Input Module
ND-6013
Data Acquisition Module
ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.
-
Product
8 Channels, RTD Measurement
RT1
-
The module provides 8 measurement channels, and can be programmed for interfacing to 2, 3, and 4-wire platinum RTD sensor configurations. The 4-wire mode (default) is the most accurate, providing excellent stability and repeatability. The RTD channels feature individual A/D converters and precision excitation/current drive. Programmable lead-wire compensation is provided for inherently less accurate 2 and 3-wire configurations. All RTD channels are self-aligning because each channel is automatically "aligned" on a rotating basis to eliminate offset and gain errors throughout the operating envelope. Programmability for expected resistance range and wire modes allows for optimization of scaling/resolution, as well as flexibility in reading many RTD types.
-
Product
PXI RTD Simulator Module, 4 Channel, PT1000
40-263-503
Simulator
The 40-263-503 is a 4-channel PT1000 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
Wireless Precision RTD Based Temperature Data Logger with LCD
RFRTDTemp2000A
-
The RFRTDTemp2000A is an RTD-based, wireless temperature data logger with display. This data logger is ideal for applications that require high accuracy temperature monitoring such as within laboratories, pharmaceutical and biotech industries. The RFRTDTemp2000A accepts 2, 3 or 4 wire 100Ω platinum RTD’s and features a device accuracy of +/-0.5°C.
-
Product
Miniature In Head RTD/ Slidewire Temperature Transmitter
HTR200
-
The HTR200 ‘smart’ transmitter is designed for use with RTD or Slidewire sensors. It is integrated into the MA style head making it ideal for applications where space is restricted
-
Product
PXI RTD Simulator Module, 4 Channel, PT500
40-263-502
Simulator
The 40-263-502 is a 4-channel PT500 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
PXI RTD Simulator Module, 16 Channel, PT1000
40-263-203
Simulator
The 40-263-203 is a 16-channel PT1000 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
RTD Thermometers
-
Automatic, positive implied, negative polarityindication.Low battery indication: The “ ” is displayed when thebattery voltage drops below the operating level.Measurement rate: 1 times/second.Operating environment: 0°C to 50°C at<70% R.H.Storage temperature: -20°C to 60°C, 0 to 80% R.H. withbattery removed from meter.Accuracy: Stated accuracy at 23°C±5°C, <75% R.H.Battery: 1.5Vx4pcs AAA size.Dimensions: 160mm(H) x 83mm(W) x 38mm(D).Weight: approx. 255g including batteries.
-
Product
RTD Calibrators
-
Practical Instrument Electronics, Inc.
PIE has an RTD calibrator to fit your needs from the PIE 510B single type RTD simulator to the advanced troubleshooting capabilities of the PIE 311Plus. Have you had issues in the past where your RTD calibrator wouldn’t work with some of the instruments in your plant? Our RTD calibrators are guaranteed to be compatible with all process RTD inputs including all brands of smart temperature and multivariable transmitters, PLC input cards, DCS systems and multichannel recorders.
-
Product
Calibrator RTD Process Calibrator
VA720
-
Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD
Calibrator RTD calibrator Source and measure 7 RTD type devices ( PT10, PT50, PT100, PT200, PT500, PT1000(385), PT100(JIS)).
-
Product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
783863-02
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
Platinum RTD Sensor - PT100 - 3 Wire 1 meter long
-
For precision temperature sensing, nothing beats a Platinum RTD. Resistance temperature detectors (RTDs) are temperature sensors that contain a resistor that changes resistance value as its temperature changes, basically a kind of thermistor. In this sensor, the resistor is actually a small strip of Platinum with a resistance of 100 ohms at 0C, thus the name PT100. Compared to most NTC/PTC thermistors, the PT type of RTD is much most stable and precise (but also more expensive) PT100's have been used for many years to measure temperature in laboratory and industrial processes, and have developed a reputation for accuracy (better than thermocouples), repeatability, and stability.
-
Product
Thermocouple & RTD Termometers
-
Amprobe thermocouple thermometers give you a professional way to measure, monitor and log temperature. Eight models let you choose the accuracy and feature set you need. For superior accuracy and stability in a process environment, choose an Amprobe RTD thermometer.
-
Product
RTD Measurement for VMEbus
VME390
-
The VME390 features 24 two, three or four wire high-accuracy PT100 measurement channels. Each channel has programmable alarm limits on which an interrupt can be issued.
-
Product
Platinum and Nickel RTD Temperature Sensors
-
Accurate, repeatable and robust resistance temperature detector (resistance thermometers) sensor assemblies manufactured provide fast temperature response and can be applied in most temperature measurement and control applications.
-
Product
PXI RTD Simulator Module, 12 Channel, PT1000
40-263-303
Simulator
The 40-263-303 is a 12-channel PT1000 RTD Simulator. The 40-263 range is a cost effective method of simulating PT100, PT500 or PT1000 RTDs. It supports 4, 8, 12, 16, 20 or 24 channels in one or two PXI slots. Also, channels are able to be set as short or open circuit to simulate faulty wiring to a sensor.
-
Product
RTD Simulator PCI Card 6-Channel PT1000
50-262-102
Simulator
This RTD Simulator is a PCI card that supports 6 channels of RTD simulation. The card can provides a setting resolution of <90mΩ (also available in <8mΩ - PT100) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
Product
PCI RTD Simulator Card 6-Channel PT100
50-262-101
Simulator
This RTD Simulator is a PCI card that supports 6 channels of RTD simulation. The card provides a setting resolution of <8mΩ (also available in <90mΩ - PT1000version) and a resistance accuracy of better than 0.1% on all channels. Each simulation channel is able to provide a short or open circuit setting to simulate faulty wiring connections to a sensor. Calibration or verification of each resistor channel can be verified by using the calibration port connected to a high performance DMM and a supplied software package.
-
Product
NI-9216, 8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module
785186-01
Temperature Input Module
8-Channel, 400 S/s Aggregate, 0 Ω to 400 Ω, PT100 RTD C Series Temperature Input Module - The NI‑9216 is a resistance temperature detector (RTD) input module. You can configure the NI‑9216 for two sample rate modes: high sample rate or high resolution. The NI‑9216 is compatible with 3‑ and 4‑wire RTD measurements, and it automatically detects the type of RTD (3-‑or 4‑wire) connected to the channel and configures each channel for the appropriate mode. The module provides per channel current excitation. The NI‑9216 features calibration and includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and a high common-mode voltage range.
-
Product
4-Ch RTD Input EtherCAT Slice IO Module
AMAX-5015
-
RTD InputChannels : 4Input Connections : 2 or 3 wireResolution : 16 bit with ±0.1% FSR accuracySample Rate: 100 sample/s (per channel)Burn-out detection: Yes
-
Product
Probes
RTD
-
No matter the application, ThermoWorks has a probe for you: penetration probes, immersion probes, air probes, surface probes, wire probes, even specialized probes like griddle probes, burger probes, pipe clamp probes, and probes for medical and lab use. Choose from standard tip, reduced tip, corkscrew tip, alligator clip, or needle probes; different handle types; and straight, coiled, stainless overbraid or even armored cables. Sensor types include type T or type K thermocouples, RTD sensors and our Pro-Series® line of thermistor probes.