IR Calibrators
controlled sources of thermal radiation, used to calibrate infrared radiation devices.
-
product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 3.5 Mm, 2 Port
85093D
The Keysight 85093D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
product
High Precision Angular Positioning Calibration and Geometry Inspection
LabStandard
Rotary Precision Instruments UK Ltd
Ultra precise rotary tables intended for fine inspection, metrology and test applications.Designed for horizontal and vertical applications with self-locking worm gearing and a high accuracy angular encoder ensures sensitivity and fine positioning for metrology and precision testing.
-
product
Calibration
ION Science recommends that your instruments are recalibrated on an annual basis to ensure they continue to provide you with accurate, reliable results and that they maintain their extended warranty. Choose the right calibration solution from our range below.
-
product
IR CAMERAS
IRC800
Sierra Olympia Technologies Inc.
The IRC800 Series cameras offer the ultimate in flexibility for research scientists. Camera operators can vary integration times, frame rates and cold filters to meet the most precise testing requirements making the IRC800 the perfect instrument for prototyping system development or where application requirements may change. A 1/3-liter LN2 pour-filled Dewar assembly maintains temperature for up to 20 hours unpowered and 9 hours powered which makes the IRC800 Series perfect for Scientific Imaging, Process Analysis and Quality Assurance. A developer’s kit is available for users who wish to create their own applications.
-
product
Resistors for Calibration of Current Measuring Systems and Sensors/Transducers
ChenYang Technologies GmbH & Co. KG
Is designed and made according to the Standard JB/T8225-1999 for DC resistors used in laboratory and electrical engineering.By using full closed structure and automatictemperature control it ensures resistor good long-term stability and small temperaturecoefficient. This DC resistor is very suitablefor DC current measurement and calibration of current measuring systems and current sensors. The maximal measuring current is 100A with measuring accuracy of ±0.02%
-
product
Multi-Cal Pressure Calibrator
MC
Series MC Portable Multi-Cal Pressure Calibrator performs a wide variety of simple and complex pressure based measurement, test, and calibration operations. Modular sensor design allows user to select pressure measurement range for application flexibility.
-
product
Precision Sound Level Calibrator
CAL200
The Larson Davis CAL200 Sound Level Calibrator is a battery operated precision microphone calibrator used for the calibration of sound level meters and other sound measurement equipment.
-
product
Electrical Calibration
Beijing GFUVE Electronics Co.,Ltd.
Checking condition , performance , sensitivity and accuracy of any electrical device.
-
product
Multiport Electronic Calibration Module (ECal), DC To 20, 6-ports
N7564A
A series of multiport ECal that cascade-able up to 36-ports which makes it possible to calibrate a wide frequency range from DC up to 20 GHz without making numerous connections during calibration process. Ideal for multiport measurement application with VNA in such as high-volume PA/FEM, massive MIMO antenna or high-speed digital interconnect test applications
-
product
Temperature Measurement IR Sensors & Detectors
1M
A thin film-based thermopile with a 1.0mm diameter active area with good signal-to-noise ratio in a TO-5 package and a moderate time constant of 32ms with Argon encapsulation gas.
-
product
RF Electronic Calibration Module (ECal), DC/300 KHz To 7.5 GHz, 7-16, 2 Port
85098D
The Keysight 85098D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
product
Air Data Calibration
Fluke calibration offers digital pressure monitors, air data calibrators and laboratory standards for air data pressure range calibrations. Each of these systems feature pressure ranges, measurement units and features specific to calibrate air data test sets and RVSM compliant air data instruments. Models include 2468 Ruska and ADCS-601 DHI primary level standards; 7750i Ruska air data controller/calibrator and RPM4-AD DHI reference pressure monitor.
-
product
Vibration Transducers Calibration System
The system is used for calibration of vibration transducers as well as:*ICP and charge accelerometers;*piezoelectrical and capacitive vibration transducers;*vibration-measuring instruments.
-
product
Calibration Lead Precision Resistor - Single
40-975-009-SL1
The cable assembly is specifically designed to connect to the 9-Pin D-Type calibration port located on the front panel of Pickering Interfaces Module Part Numbers 40-260, 40-261, 40-262, 40-263 and 40-265.
-
product
Phasor Measurement Unit Calibration System
6135A/PMUCAL
The 6135A/PMUCAL system is the only fully automated and traceable PMU calibration system available today. It fully complies to the IEEE C37.118.1™-2011 and section 7 of IEEE C37.242:2013 standards for PMU operation and verification.
-
product
Electrical Calibration
Multifunction and special calibrators for electrical laboratories. All Meatest calibrators support computer assisted automated calibration to save your time.
-
product
Multiport Calibrated Measurements With Switch Instruments
S97553B
This application provides a macro which enables full multiport error correction and measurement capabilities using external switch instruments
-
product
Voltage Calibrators
Practical Instrument Electronics, Inc.
PIE has a voltage calibrator to fit your needs from the PIE 235 voltage and pH simulator to the advanced troubleshooting capabilities of the PIE 532 milliamp and voltage calibrator. The PIE 532 includes our patented Loop Diagnostic Technology! All the voltage/milliamp calibrators have fuse-less protection, rugged design and long battery life. With the PIE 535, source 4 to 20 milliamps or 10 to 50 milliamps into loop instruments and drive final control elements such as valves and actuators with up to 42 volts.
-
product
Electronic Calibration Module (ECal), 18 GHz, Type-N, 50 Ohm, 2-port
N4690D
The Keysight N4690D microwave electronic calibration (ECal) module makes calibration of Keysight vector network analyzers fast, easy and accurate. The N4690D is a precision 2-port ECal module that supports 50-ohm type-N connectors up to 18 GHz. Select either female-female, male-male, or female-male connectors. The plastic storage case for the N4690D is included for securing your ECal module and accessories.
-
product
Panel Meter Calibrator
1040C/CU
Calibrate panel meters, transducers, circuit breakers and relay units with Model 1040C, a portable, field-ready unit featuring eight key calibration functions.
-
product
IR Thermal Camera
AMG8833
This is the Thermal Camera FeatherWing: thanks to the Panasonic AMG8833 8x8 GridEYE sensor, it adds heat-vision to any Feather main board. Using our Feather Stacking Headers or Feather Female Headers you can connect a FeatherWing on top of your Feather board and let the board take flight!This part will measure temperatures ranging from 0°C to 80°C (32°F to 176°F) with an accuracy of +- 2.5°C (4.5°F). can detect a human from a distance of up to 7 meters (23) feet.
-
product
Electro-optic Test Bench for IR Detectors
BIRD 210
Testing detectors requires the implementation of ultra-low noise driving electronics and presenting high quality optical stimuli to the detector under test. This meets all these requirements and allows to test any type of detector by easily implementing the detector’s driving signals and providing exhaustive and accurate measurement results.
-
product
MP field sources calibration set
The MP field source calibration set is used to measure electric or magnetic fields in a frequency range up to 3 GHz. RF fields or transient fields can be measured. The MP field source calibration set is used to check fields of the Langer EMV-Technik GmbH field sources, fields of TEM cells and IC striplines.
-
product
4-in-1 OSLT Calibration Kit, DC to 26.5 GHz, Type-3.5 mm (f) 50 Ohm
CK521A
The Network Analyzer Calibration Kits with open, short, load, and thru (OSLT) provide the RF components needed to enable stable and accurate error correct measurements. Calibration of a network analyzer using Spanawave's Network Analyzer Calibration Kits allow for precise measurements. The Calibration Kits offer broad test equipment coverage for use with the 8003 Scalar Network Analyzer as well as being compatible with most network analyzers produced by other manufacturers. Spanawave calibration kits yield complete calibrations, as it takes into consideration the three major sources of systematic error correction by one port calibration at both ports.
-
product
Calibration
RF Test Equipment
We calibrate following types of RF test equipment:EMF test systems (frequency selective)EMF test systems (broadband)Field strength transfer standards (e.g. RefRad)Line Impedance Stabilisation Network (LISN)Cable, attenuator, couplerAntennaField Probe
-
product
IR Linear and 2D Sensor Array Modules
Excelitas offers Linear and 2D IR Imager Arrays based upon our Thermopile Technology. All Arrays are provided as plug-and-play Modules featuring a sensing chip, robust metal housing with focusing lens, a PCB with microprocessor for calibration and bus interface and a quick connector for streamlined plug-and-play integration. We offer 8-pixel, 16-pixel and 32-pixel Linear IR Imager Array Modules for field-proven effectiveness in scanning presence detection, non-contact temperature measurement, smart-home products, and office electronics. Custom solutions also available upon request.
-
product
Bench Power Supply, Calibrated w/Data, Adjustable, 1 Output, 0 V, 30 V, 0 A, 5 A
72-2690 CAL D
The 72-2690 CAL D from Tenma is a single channel adjustable bench top power supply. It is a digitally controlled industrial grade power supply with load for a long time. This compact design power supply has complete digital control, intelligent temperature controlled fan, low noise and low ripple. It also features knob lock function to avoid improper operation. This power supply has load regulation ≤0.01% +2mV (voltage), ≤0.1% +5mA (current) and line regulation of ≤0.01% +3mV (voltage), ≤0.1% +3mA (current). The setting accuracy (25°C ±5°C) is ≤0.5% +20mV (voltage), ≤0.5% +10mA (current).
-
product
AC Calibration Standard
1U647-001
The 1U647-001 is a low cost calibration standard used to determine if a 1U632-100 or a 1U663-100 DMU requires factory calibration. Its portability makes it ideal for field-testing. The standard generates signals that simulate the aircraft’s resolvers, rotary variable transformers (RVTs), and linear variable displacement transformers (LVDTs). The unit also generates a pulse width modulated (PWM) signal, and routes the output of an ARINC 429 source to the different DMU input channels. The calibration standard connects directly to the DMU and replaces the output signals of an active extender card. Discrete switch settings simplify testing. The unit is housed in a rugged aluminum case.
-
product
Intelligent Digital Multimeter, Calibrated, 3999 Count, Mean Value, Auto, Manual Range, 3.75 Digit
72-7755 CAL DU
The 72-7755 CAL DU from Tenma is an intelligent digital multimeter. It has auto range or manual range options and dual display with maximum reading 3,999 displayed in 40 analogue bars in scale making the measured value to be seen clearly and indicating the trend of changing quickly. In addition to conventional measuring functions, there is a new breakthrough in frequency test with maximum range of 400MHz. RS232C standard serial port is equipped with meter for easy connection with computer to realize macro recording and monitoring and capture of transient dynamic data, displaying change of waveform during measurement, providing data and evidence to engineering technicians for scientific research. This is also a highly applied digital multimeter of high performance with full input protection and display backlight. The orange and grey colour meter features 73mm × 50mm size LCD, CAT III 1000V and CAT IV 600V safety ratings.
-
product
IR Thermometers
Is a sensor that consists of a lens to focus the infrared (IR) energy on to a detector, which converts the energy to an electrical signal that can be displayed in units of temperature after being compensated for ambient temperature variation.