Signal Conditioning
The processing of signals to reduce noise level, amplify, attenuate, or otherwise condition.
See Also: Signal, Signal Sources, Signal Processing, Signal Integrity, Signal Proccessing, Signal Analyzers, Signaling, Signal Generators, Signal Meters, Signal Conditioners
-
product
Tactical Grade Inertial Measurement Unit (IMU)
ADIS16490 iSensor
The ADIS16490 iSensor® device is a complete inertial system that includes a triaxial gyroscope and a triaxial accelerometer. Each inertial sensor in the ADIS16490 combines industry-leading iMEMS® technology with signal conditioning that optimizes dynamic performance. The factory calibration characterizes each sensor for sensitivity, bias, alignment, and linear acceleration (gyroscope bias). As a result, each sensor has its own dynamic compensation formulas that provide accurate sensor measurements. The ADIS16490 provides a simple, cost-effective method for integrating accurate, multiaxis inertial sensing into industrial systems, especially when compared with the complexity and investment associated with discrete designs. All necessary motion testing and calibration are part of the production process at the factory, greatly reducing system integration time. Tight orthogonal alignment simplifies inertial frame alignment in navigation systems. The SPI and register structure provide a simple interface for data collection and configuration control.
-
product
PCI-6289, 32 AI (18-Bit, 625 kS/s), 4 AO (2.8 MS/s), 48 DIO PCI Multifunction I/O Device
779111-01
32 AI (18-Bit, 625 kS/s), 4 AO (2.8 MS/s), 48 DIO PCI Multifunction I/O Device - The PCI‑6289 offers analog I/O, correlated digital I/O, two 32‑bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
product
TX / RX Module
RF Lambda’s TX /RX modules include both a block upconverter and downconverter. They can include front end amplifiers for lower noise figure or power amplifiers for high output power of signal conditioning and image rejection as required.
-
product
PCI-6281, 16 AI (18-Bit, 625 kS/s), 2 AO (2.8 MS/s), 24 DIO PCI Multifunction I/O Device
779109-01
The PCI‑6281 offers analog input, correlated digital I/O, two 32‑bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
product
PXI-6229, 32 AI (16-Bit, 250 kS/s), 4 AO, 48 DIO, PXI Multifunction I/O Module
779115-01
32 AI (16-Bit, 250 kS/s), 4 AO, 48 DIO, PXI Multifunction I/O Module—The PXI‑6229 offers analog I/O, correlated digital I/O, two 32‑bit counter/timers, and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
product
Miniature Axial Extensometers
Model 3442
Jinan Testing Equipment IE Corporation
Weighing as little as 8 grams, these miniature extensometers are designed to have very low operating force with minimal specimen influence. All use an improved version of Epsilon’s dual flexure design which makes them very rugged for their size. With a module height of 15.2 mm (0.6 inches), they will fit in the limited space between grips that is typical with small test samples. Gauge lengths can be as short as 3 mm or as long as 50 mm. A newly designed gage setting pin and assembly allows the gauge length to be set accurately and repeatably to ASTM and ISO requirements for all gauge lengths. Reengineered quick attach wire forms provide simple and secure specimen attachment. Wire forms for round and flat specimens are included, as well as flat, 3-point, and vee knife edges. The wire forms may be removed to enable mounting using elastic bands or springs. A tethering attachment point provides fall protection and enables counterbalancing of the extensometer’s weight when testing delicate specimens.Model 3442 extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller and Epsilon will equip the extensometer with a compatible connector wired to plug directly into the controller. For systems lacking the required electronics, Epsilon can provide a variety of solutions for signal conditioning and connection to data acquisition systems, chart recorders, or other equipment.
-
product
Amplifiers
Amplifiers from Analog Devices deliver both high performance and high value. These amplifier ICs combine circuit design, manufacturing process innovation, and applications expertise to create products that simplify signal conditioning design.
-
product
RS-422/RS-485 Repeater
ND-6510
ADLINK's NuDAM data acquisition modules make up a total acquisition network and control system. Up to 256 NuDAM modules an be romotely controlled on any RS-485 network from a host computer, via a single serial RS-232, allowing communication from as far as 4000 feet from the host. Based on the RS-485 multi-drop network system, each module has a unique address ID, whereby simple ASCII command & response protocols through the standard RS-485 interface can control all the NuDAM modules in the RS-485 network. The NuDAM modules provide direct communications with a wide variety of sensors, perform all signal conditioning, scaling, linearization and conversion, and can acquire measurements of temperature, pressure, flow, voltage, current, and multiple digital signal types.
-
product
Power Quality Analyzer
PQM-703
Power quality analyzer PQM- 703 is a technically advanced product that allows for comprehensive measurements of the quality of electricity , analysis and recording of power network parameters, for frequencies 50/60 Hz in accordance with European standard EN 50160. PQM -703 is another representative of a well, known family of analyzers line PQM- 70x . In relation to the PQM -702 has new functions like recording of transients with max. sampling frequency 10 MHz (rapid changes in voltage) and control signals. Minimal transient capturing time is 650 ns. It is intended for a very wide range of users who need to control the quality of power with a mobile device , which fulfills the requirements of a multi-sheet standard IEC 61000 for class A analyzers. This applies to measurement accuracy, measurement methods, and synchronization of time with a standard signal. The last condition is met with a built-in GPS module with an internal antenna. If the analyzer is installed inside, it is possible to use an additional antenna with a 10m-long wire. If the antenna is situated outside, GPS signal will be attainable without any problems and used for the synchronization of an internal clock.
-
product
NI-9230, 3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
783824-01
3-Channel, 12.8 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9230 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9230 is also compatible with smart TEDS sensors. The NI‑9230 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
Block Up-Converter
RF Lambda’s block up-converters are used to convert IF frequencies up to RF. They can include power amplifiers for high output power and signal conditioning such image rejection as required by the system.
-
product
Power Measurements Conditioner
The Power Measurements Conditioner provides voltage and current signal conditioning for a supported data acquisition module or device to make up to four simultaneous power measurements per conditioner. It also includes attenuation for voltage channels up to 2,000 V and has power, communication, and signal lines for current measurements from current transducers.
-
product
Threshold Detectors
A threshold detector is a device or system that produces an output signal only when the input signal, value, or condition exceeds or drops below a predefined limit, known as the threshold
-
product
QuadPOD Conditioning Interface
JT 2147/VPC
The JT 2147/VPC is a variant of the JTAG Technologies QuadPOD signal conditioning interface specifically designed for use within Virginia Panel Corporation’s mass interconnect interface. The unit integrates both the JT 2148 transceiver circuitry, two independent, programmable TAP modules (of type JT 2149) and two TAP modules with I/O (of type JT 2149/MPV) on a single board that interfaces via the VPC QuadraPaddle connectors type G20x or G14x.
-
product
Dual-Axis Accelerometer For HS3/4/4-DIFF Handyscopes, +/- 2G
TP-ACC20-25
The Accelerometer is a low cost, low power, complete dual-axis accelerometer with signal conditioned voltage outputs. The output signals are analog voltage proportional to acceleration. The Accelerometer is capable of measuring both positive and negative accelerations to at least +/- 2G.
-
product
Signal Conditioning
Mantracourt’s analogue output strain gauge signal conditioning modules offers a flexible solution for any analogue requirement.
-
product
Trace Level Chemiluminescence NO-NOy Analyzer
Model T200U NOY
Teledyne Advanced Pollution Instrumentation
The Model T200U NOy analyzer has been developed and refined specifically to address the challenges of NOy monitoring as required, for example, in the US NCore network. It uses the proven chemiluminescence principle and is coupled with a remote NOy converter via umbilical to allow measurements with a lower detectable limit of 50 ppt.The Model T200U NOy analyzer combines a gold plated reaction cell with an enhanced performance pump, special low noise photomultiplier tube, and unique signal conditioning to provide exceptional sensitivity. In addition, a pre-reactor separates the NO-O3 reaction from background chemiluminescence to allow accurate auto-zero of the analyzer. The remote NOy converter is provided with a stainless steel, NEMA 4X (IP65) enclosure and custom sample umbilical to allow a mounting height of 10 meters. In addition, the converter features a unique purge circuit designed to remove residual calibration gas.
-
product
32-CH 12-Bit 100 kS/s Isolated Analog Input Card
PCI-9113A
ADLINK PCI-9113A is a 32-CH, 12-bit, 100 kS/s isolated analog input card. The PCI-9113A provides analog inputs with 3 programmable input ranges for both bipolar and unipolar inputs. The 32-CH single-ended analog inputs can be converted to 16-CH differential analog inputs, which improve the noise rejection in harsh industrial environments. The analog inputs are isolated from the PC's system ground. This feature not only protects the PC from being damaged from surges on the signal lines, but also eliminates ground loops and common-mode problems commonly seen in industrial measurement applications. The PCI-9113A provides custom circuit area for input signal conditioning. Either signal attenuation or filtering can be applied on per channel basis. With all the features, ADLINK PCI-9113A delivers cost-effective and reliable data acquisition capabilities for ATE, sensor monitoring, data logging, power transmission, and a broad variety of industrial measurement applications.
-
product
Data Acquisition Systems
Encore Electronics manufactures a wide range of analog signal conditioning equipment, including strain gage and pressure amplifiers, frequency-to-voltage converters, thermocouple isolation amplifiers and anti-aliasing filters.
-
product
PXI-6281, 16 AI (18-Bit, 625 kS/s), 2 AO, 24 DIO, PXI Hybrid, Multifunction I/O Module
779121-01
16 AI (18-Bit, 625 kS/s), 2 AO, 24 DIO, PXI Multifunction I/O Module—The PXI‑6281 offers analog input, correlated digital I/O, two 32‑bit counter/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
product
NI-9232, 3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module
784397-01
3-Channel, 102.4 kS/s/channel, ±30 V, C Series Sound and Vibration Input Module - The NI‑9232 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The NI‑9232 is also compatible with smart TEDS sensors. The NI‑9232 incorporates software-selectable AC/DC coupling, IEPE open/short detection, and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti-aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking.
-
product
Analog Input Modules
The modules provide direct connection to a wide variety of sensors and annunciators. They perform all signal conditioning and linearization and contain no pots or DIP switches. All user-selectable settings, such as ranges are stored in nonvolatile EEPROM, which maintains these values even after power is removed.
-
product
2- to 8-Channel Anti-Alias Low-Pass Filter and Instrumentation Amplifier Card
AAF-3
The AAF-3 is a 2- to 8-channel anti-alias low-pass filter and instrumentation amplifier ISA bus plug-in board for front-end signal conditioning in PC-based data acquisition systems.
-
product
High Temperature Furnace COD Gages (1200 C or 1600 C)
Model 3548COD
Jinan Testing Equipment IE Corporation
These COD gages mount on a water-cooled bracket, which is mounted on the furnace side cut-out or with optional load frame support brackets. The standard temperature version (to 1200℃) is supplied with high purity alumina rods. The high temperature option is furnished with alpha grade silicon carbide rods. Rods are made to order to the length required for your furnace. Mounting brackets may be integrated with the furnace cut-out. Epsilon can also provide optional load frame mounting brackets to fit your test frame. Contact edges on the test sample should be somewhat rounded (not sharp knife edges) for best performance with this model. The Model 3548COD extensometers are strain gaged devices, making them compatible with any electronics designed for strain gaged transducers. Most often they are connected to a test machine controller. The signal conditioning electronics for the extensometer is typically included with the test machine controller or may often be added. In this case the extensometer is shipped with the proper connector and wiring to plug directly into the electronics. For systems lacking the required electronics, Epsilon can provide a variety of solutions, allowing the extensometer output to be connected to data acquisition boards, chart recorders or other equipment.
-
product
PCI-6284 , 32 AI (18-Bit, 625 kS/s), 48 DIO PCI Multifunction I/O Device
779110-01
32 AI (18-Bit, 625 kS/s), 48 DIO PCI Multifunction I/O Device - The PCI‑6284 offers analog input, correlated digital I/O, two 32‑bit counters/timers, and analog and digital triggering. The device delivers low-cost, reliable DAQ capabilities in a wide range of applications from simple applications in laboratory automation, research, design verification/test, and manufacturing test. You can add sensor and high-voltage measurement capability to your device with SCC or SCXI signal conditioning modules. The included NI‑DAQmx driver and configuration utility simplify configuration and measurements.
-
product
PXI/PXIe Analog Output/Current Loop Simulator Module - 8 Channel
43-765-003
The 41/43-765-003 is an 8-channel Analog Output Module designed to meet the requirements of industrial control applications utilising current loops 4 – 20mA. It consists of up to four 16-bit, digital-to-analogue converters (DAC), capable of creating four current outputs each. Output current within 0mA - 4mA and 20mA - 24mA, give the ability to simulate error or extra signalling conditions. The ±24mA mode gives the ability to simulate either sourcing or sinking sensor.
-
product
Analog Filter
SIM965
Stanford Research Systems, Inc.
The SIM965 Analog Filter is ideal for signal conditioning applications where Bessel or Butterworth filters are needed. Bessel filters offer clean step response (negligible overshoot) and linear phase response, while Butterworth filters provide excellent pass-band flatness with some overshoot
-
product
Multi-Channel Attenuation Control Unit (5-channels), DC to 6 GHz, 0 to 121 dB, 1 dB Step
J7205A
The J7205A is a multi-channel (5-channels) attenuation solution for signal attenuation and conditioning of up to5 devices under test (DUT). Operating frequency from DC to 6 GHz, with 121 dB, 1 dB steps. Exceptional 0.03 dB insertion loss repeatability per section for the entire 5 million cycles and excellent attenuation accuracy and flatness, the J7205A reduces cost of ownership and provide the best measurement accuracy.
-
product
sbRIO-9234 , Non-Enclosed, 4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module
782718-01
Non-Enclosed, 4-Channel, 51.2 kS/s/channel, ±5 V, C Series Sound and Vibration Input Module - The sbRIO‑9234 can measure signals from integrated electronic piezoelectric (IEPE) and non‑IEPE sensors such as accelerometers, tachometers, and proximity probes. The sbRIO‑9234 is also compatible with smart TEDS sensors. The sbRIO‑9234 delivers a wide dynamic range and incorporates software-selectable AC/DC coupling and IEPE signal conditioning. The input channels simultaneously measure signals. Each channel also has built-in anti‑aliasing filters that automatically adjust to your sample rate. When used with NI software, this module provides processing functionality for condition monitoring such as frequency analysis and order tracking. Non-enclosed modules are designed for OEM applications.
-
product
Expansion Board
MSXB 044
The MSXB 044 expansion board works with the iDSC 1816 to add signal conditioning to the data acquisition and anti-aliasing capabilities. Four MSXB 044 boards are included in each MSSC-8 module. Purchase the MSXB 044 as part of a complete SCS system: an enclosure and 1, 2, 3, or 4 MSSC-8 modules, for a total of 8, 16, 24, or 32 channels.





























