Electrostatic Field
is a stationary charge that is time invariant.
-
Product
Magnetic Field Measurement Systems
-
The magnetic field probe performs non-contact current measurements and can be used for real traces. The probe of higher resolution enables pinpoint measurements.
-
Product
Prototype Performance Field Testing iOS app
-
Centric's new Field Testing app provides an innovative solution for product performance feedback. Centric's Field Testing App is an example of how capturing data live, in the moment, is not only incredibly valuable but also a natural way of working. This app helps reducing costs while also improving product innovation and performance; which are ultimately keystones of great brands.
-
Product
Field Probe Positioner
-
The Field Probe Positioner FSM2315 is designed for the automation of the 16 point measurement, according to IEC/EN 61000-4-3. The system provides X and Y axis positions for continuous and step by step movement for the filed probe, 0.8m above the floor and with a 1.5m x 1.5m area, for the 16 sensor positions. A dismountable solution is available.
-
Product
Utility Field Station
1060
-
The Utility Field Station (Catalog No. 1060) is a lightweight, easy-to-use tool that helps you easily bring equipment in and out of the field while also providing a portable work station on site.
-
Product
Horizontal Field of View Vehicle Camera System
ThermoVision SS
-
The SS camera is a vehicle camera system for driver's vision has a horizontal field of view (FOV) of 55 or 90 degrees. The SS system is based on an uncooled thermal camera to provide good situational awareness day and night.
-
Product
Near Field Probes 30 MHz up to 6 GHz
XF1 set
-
The XF1 set of near field probes consists of 4 passive near field probes and one passive E field probe for making measurements in the development phase of the magnetic and electric fields in ranges from 30 MHz to 6 GHz. Due to their integrated impendance matching, the probes are less sensitive in the lower frequency range than the RF type probes. The probe heads of the XF1 set allow for the step by step identification of interference sources of the magnetic field on an electronic assembly. At first, for example the XF-R 400-1 detects the fields which the assembly emits in total. Next, using higher resolution probes the interference sources can be more precisely detected. The E field probe is used for the detection of electric interfering fields near the assemblies. With trained use of the near field probes, field orientation and field distribution can be detected. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They have an internal terminating resistance.
-
Product
EMF Fluxgate Magnetic Field Meter
LM-MP6000-EMF
-
The List-Magnetik LM-MP6000-EMF EMF fluxgate magnetic field meter (fluxgate magnetometer) can measure very weak DC and AC magnetic fields in the range of 0–400 µT (microtesla), 0–4 G (gauss), or 0–300 A/m. The device uses a fluxgate measuring probe to measure magnetic fields in the transverse direction.
-
Product
Near Field Probes 30 MHz up to 3 GHz
RF2 set
-
The RF2 near field probe set consists of 4 passive near field probes for measurements in the development phase of the magnetic field in the range from 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF2 set allow the step by step localization of interference sources of the RF magnetic field on assemblies. From greater distances the electromagnetic interference can be detected by RF-R 400-1 and RF-R 50-1 probes. The RF-B 3-2 and RF-U 5-2 probes with their higher resolution can more precisely detect the interference sources. Field orientation and field distribution on an electronic assembly can be detected through a trained special use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.
-
Product
Scientific CMOS Large Field of View Camera
Iris 15
-
The Iris 15 Scientific CMOS (sCMOS) camera provides a large field of view and the highest resolution with its 15 Megapixel design.
-
Product
Near Field Probes 30 MHz - 6 GHz
XF Family
-
The XF family consists of 4 passive magnetic field probes and 3 passive E field probes designed for measuring magnetic and E-fields in ranges from 30 MHz to 6 GHz during the development phase. Due to their integrated impendance matching the probes are less sensitive in the lower frequency range than the RF type probes.
-
Product
Single Axis AC Magnetic Field Sensor
MGCH-2
-
Macintyre Electronic Design Associa
The MGCH-2 is the lowest noise, highest sensitivity single axis AC magnetic field sensor available for the measurement of sub radio frequency fields. Because of its innovative design, the MGCH-2 amplitude response is insensitive to the frequency of the field over its 10 Hz to 100 kHz frequency band. Accuracy at 10 kHz is 0.1 dB, and the amplitude response stays within 2 dB peak-to-peak over the bandwidth.
-
Product
Electrostatic Discharge
-
Our electrostatic discharge (ESD) measurement and control solutions include charge plate monitors, sensors, resistivity meters, and voltmeters. Reliably monitor, measure, locate, and test for static electricity.
-
Product
Field Strength Meter
FIM-71 VHF
-
The Model FIM-71 is a portable, laboratory quality Field Strength Meter designed for rigorous field applications. Combining a calibrated half-wave dipole antenna and a highly accurate tuned voltmeter with a range of 140 dB, the FIM-71 is suitable for practically all types of RF emission measurements in the 45 MHz to 225 MHz spectrum. The operator can switch select wide or narrow bandwidth, peak or average value of TV or pulse modulated signals, AM or FM demodulation, and a meter dynamic range of either 20 dB or 60 dB. A dc analog output voltage, proportional to the meter indication, is provided for driving a chart recorder. A leveled output from the calibrating oscillator is available for measuring cable insertion loss, filter response, amplifier gain, and other signal ratio measurements. The 4-1/2 inch, taut band, mirrored scale meter is calibrated in volts and dB for precise measurements in field or laboratory environments.













